Okker Bijlstra

Dr. Okker Bijlstra

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in Molecular Imaging and Biology
Verified
Journal Article
Open access
PDF file
DLDaan Linders
Daan Linders
OBOkker Bijlstra
Okker Bijlstra
LFLaura C. Fallert
Laura C. Fallert
DHDenise Hilling
Denise Hilling
CUCase Western Reserve University
Case Western Reserve University
Peter KuppenPeter Kuppen
Peter Kuppen
The majority of breast cancer patients is treated with breast-conserving surgery (BCS) combined with adjuvant radiation therapy. Up to 40% of patients has a tumor-positive resection margin after BCS, which necessitates re-resection or additional boost radiation. Cathepsin-targeted near-infrared fluorescence imaging during BCS could be used to detect residual cancer in the surgical cavity and guide additional resection, thereby preventing tumor-positive resection margins and associated mutilating treatments. The cysteine cathepsins are a family of proteases that play a major role in normal cellular physiology and neoplastic transformation. In breast cancer, the increased enzymatic activity and aberrant localization of many of the cysteine cathepsins drive tumor progression, proliferation, invasion, and metastasis. The upregulation of cysteine cathepsins in breast cancer cells indicates their potential as a target for intraoperative fluorescence imaging. This review provides a summary of the current knowledge on the role and expression of the most important cysteine cathepsins in breast cancer to better understand their potential as a target for fluorescence-guided surgery (FGS). In addition, it gives an overview of the cathepsin-targeted fluorescent probes that have been investigated preclinically and in breast cancer patients. The current review underscores that cysteine cathepsins are highly suitable molecular targets for FGS because of favorable expression and activity patterns in virtually all breast cancer subtypes. This is confirmed by cathepsin-targeted fluorescent probes that have been shown to facilitate in vivo breast cancer visualization and tumor resection in mouse models and breast cancer patients. These findings indicate that cathepsin-targeted FGS has potential to improve treatment outcomes in breast cancer patients.

17 March 2022 in Life
Verified
Journal Article
Open access
PDF file
LNLisanne K.A. Neijenhuis
Lisanne K.A. Neijenhuis
LMLysanne de Muynck
Lysanne de Muynck
OBOkker Bijlstra
Okker Bijlstra
Peter KuppenPeter Kuppen
Peter Kuppen
DHDenise Hilling
Denise Hilling
MHMerlijn Hutteman
Merlijn Hutteman
Lung cancer is the most common cancer type worldwide, with non-small cell lung cancer (NSCLC) being the most common subtype. Non-disseminated NSCLC is mainly treated with surgical resection. The intraoperative detection of lung cancer can be challenging, since small and deeply located pulmonary nodules can be invisible under white light. Due to the increasing use of minimally invasive surgical techniques, tactile information is often reduced. Therefore, several intraoperative imaging techniques have been tested to localize pulmonary nodules, of which near-infrared (NIR) fluorescence is an emerging modality. In this systematic review, the available literature on fluorescence imaging of lung cancers is presented, which shows that NIR fluorescence-guided lung surgery has the potential to identify the tumor during surgery, detect additional lesions and prevent tumor-positive resection margins.

30 April 2022 in Life
Verified
Journal Article
Open access
PDF file
OBOkker Bijlstra
Okker Bijlstra
ABAlexander Broersen
Alexander Broersen
TOTimo T. M. Oosterveer
Timo T. M. Oosterveer
RFRobin A. Faber
Robin A. Faber
FAFriso B. Achterberg
Friso B. Achterberg
RSR.J. Swijnenburg
R.J. Swijnenburg
Background: Robotic liver surgery represents the most recent evolution in the field of minimally-invasive liver surgery. For planning and guidance of liver resections, surgeons currently rely on preoperative 2-dimensional (2D) CT and/or MR imaging and intraoperative ultrasonography. Translating 2D images into digital 3-dimensional (3D) models may improve both preoperative planning and surgical guidance. The da Vinci® robotic surgical system is a platform suitable for the integration of multiple imaging modalities into one single view. In this study, we describe multimodal imaging options and introduce the Robotic Liver Surgery Cockpit; Methods: in-house developed software was used and validated for segmentation and registration to create a virtual reality 3D model of the liver based on preoperative imaging. The accuracy of the 3D models in the clinical setting was objectively assessed in 15 patients by measuring tumor diameters and subjectively with a postoperative conducted questionnaire; Results: Implementation and applicability of the 3D model in the surgical cockpit was feasible in all patients and the quality of the 3D reconstructions was high in 14 (93%) of cases. Tumor diameters measured on CT and/or MR imaging were comparable to automated measurements using the segmentation software and 3D models; Conclusions: the 3D model was successfully incorporated in the robotic surgery console as part of a multimodality imaging platform and aided the surgeon in planning and guidance of the resection. Future studies should focus on further automation of 3D rendering and progress into augmented reality.

16 July 2022 in Cancers
Verified
Journal Article
Open access
PDF file
CUCase Western Reserve University
Case Western Reserve University
DLDaan Linders
Daan Linders
EAEric Abenojar
Eric Abenojar
XWXinning Wang
Xinning Wang
HHHans Marten Hazelbag
Hans Marten Hazelbag
BSBrian Straight
Brian Straight
Background: Tumor-positive surgical margins during primary breast cancer (BCa) surgery are associated with a two-fold increase in the risk of local recurrence when compared with tumor-negative margins. Pathological microscopic evaluation of the samples only assesses about 1/10 of 1% of the entire volume of the removed BCa specimens, leading to margin under-sampling and potential local recurrence in patients with pathologically clean margins, i.e., false negative margins. In the case of tumor-positive margins, patients need to undergo re-excision and/or radiation therapy, resulting in increases in complications, morbidity, and healthcare costs. Development of a simple real-time imaging technique to identify residual BCa in the surgical cavity rapidly and precisely could significantly improve the quality of care. Methods: A small-molecule, fluorescently quenched protease-substrate probe, AKRO-QC-ICG, was tested as part of a thermosensitive imaging gel formulated for topical application and imaging of the BCa surgical cavity. Results: More than forty formulations of gel mixtures were investigated to enable easy fluid application and subsequent solidification once applied, preventing dripping and pooling in the surgical cavity. The final formulation was tested using human BCa orthotopic implants in nude and NSG patient-derived xenografts (PDX) mice. This formulation of Pluronic F-127/DMSO/AKRO-QC-ICG imaging gel was found to be a good solvent for the probe, with a desirable thermo-reversible solid–gel transition and mechanical strength for distribution of AKRO-QC-ICG on the surfaces of tissue. It demonstrated excellent ability to detect BCa tissue after 10 min exposure, with a high signal-to-noise ratio both in mouse xenografts and freshly excised human lumpectomy tissue. The in vivo efficacy of the AKRO-QC-ICG imaging gel to detect BCa revealed the levels of sensitivity/specificity = 0.92/1 in 12 nude mice, which was corroborated with the sensitivity/specificity = 0.94/1 in 10 PDX mice. Conclusions: Utilization of Pluronic F-127/DMSO/AKRO-QC-ICG imaging gel for topical application to detect BCa in the surgical cavity during surgery has the potential to reduce re-excisions, with consequent savings in healthcare costs and enhancement in patient quality of life.

1 February 2024 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
TDTom H. Dijkhuis
Tom H. Dijkhuis
OBOkker Bijlstra
Okker Bijlstra
MWMats Warmerdam
Mats Warmerdam
RFRobin A. Faber
Robin A. Faber
DLDaan Linders
Daan Linders
JMJ. Sven D. Mieog
J. Sven D. Mieog
Near-infrared (NIR) fluorescence imaging is an emerging imaging technique in the surgical field that uses light with a longer wavelength than visible light (the NIR-I spectrum; 700 to 1000 nm) to extract information from superficial and subsurface structures. As a result of the favorable optical properties of human tissue, photons with a wavelength in the NIR spectrum can travel further through human tissue compared with photons with wavelengths in the visible spectrum.1 NIR fluorescence imaging is used for perfusion imaging,2 – 4 the visualization of critical anatomic structures,5 – 10 and the identification of malignant tissue.11 – 15 In oncological surgery, fluorescent dyes are frequently conjugated to a tumor-targeting moiety, e.g., antibodies or peptides,16,17 to enable tumor-targeted imaging during surgery. Moreover, in fluorescence-guided liver surgery, the non-targeted fluorescent dye indocyanine green (ICG) is used to indirectly mark colorectal metastases.18 – 20 In contrast to tumor-targeted tracers, ICG accumulates in the tumor periphery, resulting in a typical fluorescent “rim-shaped” pattern.18,21 Although the two types of dyes accumulate in different regions, they are both valuable in identifying tumor tissue and assessing tumor margins.

15 March 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
OBOkker Bijlstra
Okker Bijlstra
MBMaud M. E. Boreel
Maud M. E. Boreel
SMSietse van Mossel
Sietse van Mossel
MBMark C. Burgmans
Mark C. Burgmans
Ellen KapiteijnEllen Kapiteijn
Ellen Kapiteijn
Lioe-Fee de Geus-OeiLioe-Fee de Geus-Oei
Lioe-Fee de Geus-Oei
(1) Background: Up to 50% of patients with colorectal cancer either have synchronous colorectal liver metastases (CRLM) or develop CRLM over the course of their disease. Surgery and thermal ablation are the most common local treatment options of choice. Despite development and improvement in local treatment options, (local) recurrence remains a significant clinical problem. Many different imaging modalities can be used in the follow-up after treatment of CRLM, lacking evidence-based international consensus on the modality of choice. In this systematic review, we evaluated 18F-FDG-PET-CT performance after surgical resection, thermal ablation, radioembolization, and neoadjuvant and palliative chemotherapy based on current published literature. (2) Methods: A systematic literature search was performed on the PubMed database. (3) Results: A total of 31 original articles were included in the analysis. Only one suitable study was found describing the role of 18F-FDG-PET-CT after surgery, which makes it hard to draw a firm conclusion. 18F-FDG-PET-CT showed to be of additional value in the follow-up after thermal ablation, palliative chemotherapy, and radioembolization. 18F-FDG-PET-CT was found to be a poor to moderate predictor of pathologic response after neoadjuvant chemotherapy. (4) Conclusions: 18F-FDG-PET-CT is superior to conventional morphological imaging modalities in the early detection of residual disease after thermal ablation and in the treatment evaluation and prediction of prognosis during palliative chemotherapy and after radioembolization, and 18F-FDG-PET-CT could be considered in selected cases after neoadjuvant chemotherapy and surgical resection.