Color blindness is a serious perception problem. Suffering individuals cannot understand messages, which are carrying by many images, especially those, distributed by WWW. In this paper we are proposing three image processing methods to enhance image recognition and understanding by persons with dichromacy. Color difference image is introduced to represent color perception dissimilarity. Two color transformation methods are presented. Results of tests proved the usefulness of the methods for fast color transformation of images in the WWW environment.
1 March 2012 in Journal of Medical Imaging and Health Informatics
Nearly 10% of all upper limb amputations concern the whole arm. It affects the mobility and reduces the productivity of such a person. These two factors can be restored by using prosthetics. However, the complexity of human arm makes restoring its basic functions quite difficult. When the osseointegration and/or targeted muscle reinnervation (TMR) are not possible, different modalities can be used to control the prosthesis. In this paper the usability of electromyography (EMG) signals for such a control is evaluated. Method: first, the types of operations performed by the prosthetic arm that could be handled by EMG module were defined. The raw EMG signal, corresponding to the predefined gesture, was acquired from the surface of trapezius muscle. The pattern recognition neural network was trained to classify gestures based on recorded RAW data. Results: The neural network was trained using 56 signals corresponding to performed gestures. Optimal performance was achieved for 29 training cycles. The network was tested using data set of 56 gestures. The designed network was tested on gestures recorded from 10 volunteers. The gestures were correctly classified with nearly 84% accuracy. Conclusions: The EMG analysis is a reliable modality when it comes to hybrid interfaces for control over prosthetic arm.
An influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different position, however a precise interpretation of the obtained signal is limited.
1 January 2012 in Metrology and Measurement Systems
Disorders of the heart and blood vessels are the leading cause of health problems and death. Early detection of them is extremely valuable as it can prevent serious incidents (e.g. heart attack, stroke) and associated complications. This requires extending the typical mobile monitoring methods (e.g. Holter ECG, tele-ECG) by introduction of integrated, multiparametric solutions for continuous monitoring of the cardiovascular system. In this paper we propose the wearable system that integrates measurements of cardiac data with actual estimation
of the cardiovascular risk level. It consists of two wirelessly connected devices, one designed in the form of a necklace, the another one in the form of a bracelet (wrist watch). These devices enable continuous measurement of electrocardiographic, plethysmographic (impedance-based and optical-based) and accelerometric signals. Collected signals and calculated parameters indicate the electrical and mechanical state of the heart and are processed to estimate a risk level. Depending on the risk level an appropriate alert is triggered and transmitted to
predefined users (e.g. emergency departments, the family doctor, etc.).
Objective. The aim of the study is to investigate the effect of the signal sampling frequency and low-pass filtering on the accuracy of the localisation of the fiducial points of the photoplethysmographic signal (PPG), and thus on the estimation of the blood pressure (i.e. the accuracy of the estimation). Approach. Statistical analysis was performed on 3,799 data samples taken from a publicly available database. Four PPG fiducial points of each sample signal were examined in the study. Main results. Simulation suggests that for noise-free data, cubic spline interpolation causes the sampling frequency (in the considered range of 62.5–500 Hz) to have only limited influence on localisation of the fiducial point. Better results were obtained for the pulse transit time (PTT) than pulse arrival time (PAT) approach. The acceptable filter band depends on the selected fiducial point and PAT or PTT approach. The best results were obtained for the tangent fiducial point. Significance. The presented results make it possible to estimate the minimum requirements for the sampling frequency and filtering of the PPG signal in order to obtain a reliable estimation of blood pressure.