Exposure to air pollutants is associated with hospitalizations due to pneumonia in children. We hypothesized the length of hospitalization due to pneumonia may be dependent on air pollutant concentrations. Therefore, we built a computational model using fuzzy logic tools to predict the mean time of hospitalization due to pneumonia in children living in São José dos Campos, SP, Brazil. The model was built with four inputs related to pollutant concentrations and effective temperature, and the output was related to the mean length of hospitalization. Each input had two membership functions and the output had four membership functions, generating 16 rules. The model was validated against real data, and a receiver operating characteristic (ROC) curve was constructed to evaluate model performance. The values predicted by the model were significantly correlated with real data. Sulfur dioxide and particulate matter significantly predicted the mean length of hospitalization in lags 0, 1, and 2. This model can contribute to the care provided to children with pneumonia.
Predict the number of hospitalizations for asthma and pneumonia associated with exposure to air pollutants in the city of São José dos Campos, São Paulo State. This is a computational model using fuzzy logic based on Mamdani’s inference method. For the fuzzification of the input variables of particulate matter, ozone, sulfur dioxide and apparent temperature, we considered two relevancy functions for each variable with the linguistic approach: good and bad. For the output variable number of hospitalizations for asthma and pneumonia, we considered five relevancy functions: very low, low, medium, high and very high. DATASUS was our source for the number of hospitalizations in the year 2007 and the result provided by the model was correlated with the actual data of hospitalization with lag from zero to two days. The accuracy of the model was estimated by the ROC curve for each pollutant and in those lags. In the year of 2007, 1,710 hospitalizations by pneumonia and asthma were recorded in São José dos Campos, State of São Paulo, with a daily average of 4.9 hospitalizations (SD = 2.9). The model output data showed positive and significant correlation (r = 0.38) with the actual data; the accuracies evaluated for the model were higher for sulfur dioxide in lag 0 and 2 and for particulate matter in lag 1. Fuzzy modeling proved accurate for the pollutant exposure effects and hospitalization for pneumonia and asthma approach.
9 September 2022 in IEEE Latin America Transactions
Combined cycle power plants (CCPP) are popular in the energy sector for the production of electricity, and are the union of two thermodynamic cycles, corresponding to the steam turbine and the gas turbine. This paper presents the application of several machine learning (ML) techniques and the adaptive neuro-fuzzy inference system (ANFIS) to predict the hourly electricity production in a CCPP. The models were developed using 5-fold cross-validation with the collected features of temperature, exhaust pressure, relative humidity, ambient pressure, and electricity production per hour (the target feature). The hyperparameters of the tested models were optimized. The correlation and determination coefficients of the models were higher than 92%, showing a significant performance. The ANFIS (r = 98% e R2 = 95%) model shows the lowest values in the evaluated error metrics, compared to the other ML models. Finally, the results showed the effectiveness of ANFIS in predicting the hourly production of electricity in CCPP.
The design of full programmable type-2 membership function circuit is presented in this paper. This circuit is used to implement the fuzzifier block of Type-2 Fuzzy Logic Controller chip. In this paper the type-2 fuzzy set was obtained by blurring the width of the type-1 fuzzy set. This circuit allows programming the height and the shape of the membership function. It operates in current mode, with supply voltage of 3.3V. The simulation results of interval type-2 membership function circuit have been done in CMOS 0.35μm technology using Mentor Graphics software.
Positive Displacement Motors (PDM) are extensively used in the oilfield, either in drilling or in coiled tubing (CT) operations. They provide a higher rate of penetration and the possibility of drilling horizontal wells. For coiled tubing operations, PDMs can mill through obstructions and enable shut-in wells to work again. One of the major challenges while using these tools is the motor stalling, which can lead to serious damage to the PDM and lost time events in drilling and workover rigs. These events result in total losses of hundreds of thousands of dollars, and their avoidance mostly depends on trained and fully aware equipment operators. If a PDM starts to stall, the pumping needs to be halted immediately or the tool may fail. This paper describes the use of a Fuzzy Inference System (FIS) to detect the stalling events as they start to happen using the acquisition data from the coiled tubing unit, the output of the FIS could then trigger an alarm for the operator to take the proper action or remotely stop the pump. The FIS was implemented in Python and tested with real CT milling acquisition data. When tested using real data, the system analyzed 68,458 acquisition points and detected 94% of the stalling events across this data during its first seconds, whereas, during the real job, a CT operator could take longer to notice this event and take the proper action, or even take no action. If the FIS was applied on a real coiled tubing acquisition system, it could reduce PDMs over-pressurization due to stalling, leading to an increase on its useful life and decrease on premature failure. As of now there is no similar system in the market or published and this kind of operation is fully performed using human supervision only.
A fuzzy linguistic model based on the Mamdani method with input variables, particulate matter, sulfur dioxide, temperature and wind obtained from CETESB with two membership functions each was built to predict the average hospitalization time due to cardiovascular diseases related to exposure to air pollutants in São José dos Campos in the State of São Paulo in 2009. The output variable is the average length of hospitalization obtained from DATASUS with six membership functions. The average time given by the model was compared to actual data using lags of 0 to 4 days. This model was built using the Matlab v. 7.5 fuzzy toolbox. Its accuracy was assessed with the ROC curve. Hospitalizations with a mean time of 7.9 days (SD = 4.9) were recorded in 1119 cases. The data provided revealed a significant correlation with the actual data according to the lags of 0 to 4 days. The pollutant that showed the greatest accuracy was sulfur dioxide. This model can be used as the basis of a specialized system to assist the city health authority in assessing the risk of hospitalizations due to air pollutants.