The aim of this study was to determine the reproducibility of clinical centric relation (CR) registration techniques (bimanual manipulation, chin point guidance and Roth's method) by means of condyle position analysis. Thirty two fully dentate asymptomatic subjects (16 female and 16 male) with normal occlusal relations (Angle class I) participated in the study (mean age, 22.6 ± 4.7 years). The mandibular position indicator (MPI) was used to analyze the three-dimensional (anteroposterior (ΔX), superoinferior (ΔZ), mediolateral (ΔY)) condylar shift generated by the difference between the centric relation position (CR) and the maximal intercuspation position (MI) observed in dental arches. The mean value and standard deviation of three-dimensional condylar shift of the tested clinical CR techniques was 0.19 ± 0.34 mm. Significant differences within the tested clinical CR registration techniques were found for anteroposterior condylar shift on the right side posterior (Δ Xrp; P ≤ 0.012); and superoinferior condylar shift on the left side inferior (Δ Zli; P ≤ 0.011), whereas between the tested CR registration techniques were found for anteroposterior shift on the right side posterior (ΔXrp, P ≤ 0.037) and superoinferior shift on the right side inferior (ΔZri, P ≤ 0.004), on the left side inferior (ΔZli, P ≤ 0.005) and on the left side superior (ΔZls, P ≤ 0.007). Bimanual manipulation, chin point guidance and Roth's method are clinical CR registration techniques of equal accuracy and reproducibility in asymptomatic subjects with normal occlusal relationship.
Objectives: Programming of joint mechanism/parameters (sagittal condylar inclination and Bennett angle) of adjustable dental articulators is a prerequisite for performing positions and movements of the mandible. The aim of the study was to test significant differences between the two methods (wax eccentric records and Arcus Digma device) of measuring these joint parameters by using three different dental articulators (SAM 3, Protar 7; and Artex CR). Materials and Methods: Thirty asymptomatic younger (age 25.7 +/- 2.9 years) subjects (dental medicine students) divided by gender, with normal occlusion (Angle class I) participated in the study. After taking anatomical impressions of both dental arches, master casts were made of hard dental plaster for each subject. The values of the left and right sagittal condylar inclination and Bennett angle by the two methods of wax eccentric protrusive and lateral records and Arcus Digma device were measured for the purpose of programming the mentioned joint parameters in three different articulator systems. Results: The average values of the measured parameters of sagittal condylar inclination and Bennett angle of wax eccentric records were higher (ranging from 5 degrees to 10 degrees) in relation to the values measured by Arcus Digma device. Statistically significant differences found between the measured joint parameters (p <0.025) were influenced by the articulator system design and measurement methods (t-test for dependent samples and MANOVA). Conclusion: The use of Arcus Digma device should be considered reliable and valid for individualized programming of dental articulators, rather than the use of wax eccentric records.
The purpose of the study was to determine whether the hinge axis registration and the transfer modality (facebow transfer vs. average mounting) from the subject to the articulator affect the three-dimensional condylar shift between the centric relation (CR) and the maximum intercuspation (MI) position. The study was comprised of 32 fully dentate subjects (16 male and 16 female). Only the asymptomatic participants with normal occlusal relations (Angle class I) aged 20 - 33 (mean age 22.6 ± 4.7) met the inclusion criteria. Three-dimensional condylar shift (anteroposterior, superoinferior and mediolateral shift) between the centric relation position (CR) and the maximum intercuspation (MI) position was analyzed by means of Mandibular Position Indicator (SAM Prazisionstechnik GmbH, Muenchen, Germany). The average three-dimensional condylar shift was 0.13 ± 0.12 mm for facebow transfer and 0.22 ± 0.23 mm for average mounting. There were no statistically significant differences noted between genders. The results of the Mann-Whitney test showed statistically significant differences for anteroposterior and superoinferior condylar shift (P < 0.001). However, the difference in the mediolateral shift was not statistically significant. In order to find discrepancies within the three-dimensional condylar shift, facebow transfer proved to be more accurate than the average mounting in the semi-adjustable articulator. However, the average value of three-dimensional shifts of the condyle did not differ from normal values and they did not have clinical significance. Thus, both ways of transfer modalities (facebow transfer and average mounting) in asymptomatic subjects with normal occlusion can be considered reliable.
Objectives: The purpose of this study was to evaluate shade matching ability of dental professionals and students using the VITA 3D-Master shade guide. Materials and methods: A hundred and twenty participants have been assigned to one of four groups as follows: specialists in prosthodontics (SPs), residents in prosthodontics (RPs), dental technicians (DTs) and dental students (DSs). The Toothguide Training Box (TTB) was used to test the participants’ shade-matching ability based on using 3 exercises and a final test. The mistakes were recorded during the exercises and mistake ratios (MR) were calculated. Time, scores, and color difference values (ΔE) were recorded and calculated. The one-way ANOVA was used to analyze the differences, and multiple regression analyses were used to evaluate the relationship in mean MRs, time, score and ΔE values between the groups. Results: Male participants needed significantly greater amount of time than females to complete the final test (P<0.05). Male SPs achieved a significantly lower percentage of mistake ratios in second exercise than RPs (P<0.05), needed significantly less time than DSs to complete the final test and achieved significantly higher scores than RPs (P<0.05). Female SPs assessed the highest and DSs and RPs the lowest color differences (P<0.05). The results obtained from the exercises and final tests highly affected the amount of estimated color difference in both male and female groups (by 78% and 76%, respectively). Conclusions: Within the population tested, gender of the participants showed a significant impact on quality of shade matching of dental professionals and students.
Objective: The aim of this study was to examine whether the method of surface treatment of the acrylic teeth and reinforcement of the denture base (carbon fibers) affect the reduction of stress concentration for gap initiation at the interface of acrylic teeth and denture base as a measure of bond strength. Materials and methods: Samples of cross-sections of acrylic teeth and denture base were isolated from four pairs of complete acrylic dentures (with and without reinforcement of the denture base) and were subsequently subjected to compressive loading in a universal testing machine simulating two different occlusions. Selected groups of acrylic teeth (central incisors, first premolars, and first molars) from complete dentures were treated in various ways (untreated, mechanical, chemical, and mechanical-chemical). The gap size at the interface of acrylic tooth and denture base was measured using a light inverted microscope on selected acrylic teeth of individual quadrants. The oneway analysis of variance was used to investigate the influence of denture base reinforcement and different methods of surface treatment of the acrylic tooth on bond strength at the level of statistical significance of p s 0.001. Results: Microscopic analysis of gap size measured at five selected points at the interface between the acrylic teeth and the base of the complete denture ranged from 40 to 144 micrometers. The one-way analysis of variance showed a statistically significant difference between the arithmetic means of the measured gap sizes concerning different methods of surface treatment of the acrylic teeth. Conclusion: The fracture strength, or load-bearing capacity, of complete dentures reinforced with carbon fibers was increased compared to complete dentures with non-reinforced bases. Reduction in gap size at the interface between the acrylic teeth and the base of complete dentures was influenced by the mechanical-chemical treatment of the lower surface of acrylic teeth, while reinforcement of the complete denture base with carbon fibers had no effect on the bond strength.