Magalie Viallon

Dr. Magalie Viallon

1. UJM-Saint-Etienne, INSA, CNRS UMR 5520, INSERM U1206, CREATIS, University of Lyon, F-42023 Saint-Etienne, France
+1
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2007 in Hepatology
Verified
Journal Article
Open access
PDF file
MLMaïté Lewin
Maïté Lewin
APArmelle Poujol-Robert
Armelle Poujol-Robert
PBPierre-Yves Boelle
Pierre-Yves Boelle
DWDominique Wendum
Dominique Wendum
ELElisabeth Lasnier
Elisabeth Lasnier
RPRaoul Poupon
Raoul Poupon
Liver biopsy is the gold standard for assessing fibrosis but has several limitations. We evaluated a noninvasive method, so-called diffusion-weighted magnetic resonance imaging (DWMRI), which measures the apparent diffusion coefficient (ADC) of water, for the diagnosis of liver fibrosis in patients with chronic hepatitis C virus (HCV). We analyzed 20 healthy volunteers and 54 patients with chronic HCV (METAVIR: F0, n = 1; F1, n = 30; F2, n = 8; F3, n = 5; and F4, n = 10) prospectively included. Patients with moderate-to-severe fibrosis (F2-F3-F4) had hepatic ADC values lower than those without or with mild fibrosis (F0-F1; mean: 1.10 ± 0.11 versus 1.30 ± 0.12 × 10−3 mm2/s) and healthy volunteers (mean: 1.44 ± 0.02 × 10−3 mm2/s). In discriminating patients staged F3-F4, the areas under the receiving operating characteristic curves (AUCs) were 0.92 (±0.04) for magnetic resonance imaging (MRI), 0.92 (±0.05) for elastography, 0.79 (±0.08) for FibroTest, 0.87 (±0.06) for the aspartate aminotransferase to platelets ratio index (APRI), 0.86 (±0.06) for the Forns index, and 0.87 (±0.06) for hyaluronate. In these patients, the sensitivity, specificity, positive predictive value, and negative predictive value were 87%, 87%, 72%, and 94%, respectively, with an ADC cutoff level of 1.21 × 10−3 mm2/s. In discriminating patients staged F2-F3-F4, the AUC values were 0.79 (±0.07) for MRI, 0.87 (±0.05) for elastography, 0.68 (±0.09) for FibroTest, 0.81 (±0.06) for APRI, 0.72 (±0.08) for the Forns index, and 0.77 (±0.06) for hyaluronate. Conclusion: This preliminary study suggests that DWMRI compares favorably with other noninvasive tests for the presence of significant liver fibrosis. (Hepatology 2007.)

1 May 2010 in European Journal of Radiology
Verified
Journal Article
Closed access
MVM.I. Vargas
M.I. Vargas
Magalie ViallonMagalie Viallon
Magalie Viallon
DND. Nguyen
D. Nguyen
JBJ.Y. Beaulieu
J.Y. Beaulieu
JDJ. Delavelle
J. Delavelle
MBM. Becker
M. Becker


2 October 2007 in Neuroradiology
Verified
Journal Article
Closed access
PDF file
MVMaria Isabel Vargas
Maria Isabel Vargas
JDJacqueline Delavelle
Jacqueline Delavelle
HJHelmi Jlassi
Helmi Jlassi
BRBénédict Rilliet
Bénédict Rilliet
Magalie ViallonMagalie Viallon
Magalie Viallon
Karl Olof LovbladKarl Olof Lovblad
Karl Olof Lovblad

31 August 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PAPierre Andonian
Pierre Andonian
Magalie ViallonMagalie Viallon
Magalie Viallon
CGCaroline Le Goff
Caroline Le Goff
CBCharles de Bourguignon
Charles de Bourguignon
CTCharline Tourel
Charline Tourel
PCPierre Croisille
Pierre Croisille
In sports medicine, there is increasing interest in quantifying the elastic properties of skeletal muscle, especially during extreme muscular stimulation, to improve our understanding of the impact of alterations in skeletal muscle stiffness on resulting pain or injuries, as well as the mechanisms underlying the relationships between these parameters. Our main objective was to determine whether real-time shear-wave elastography (SWE) can monitor changes in quadriceps muscle elasticity during an extreme mountain ultra-marathon, a powerful mechanical stress model. Our study involved 50 volunteers participating in an extreme mountain marathon (distance: 330 km, elevation: +24,000 m). Quantitative SWE velocity and shear modulus measurements were performed in most superficial quadriceps muscle heads at the following 4 time points: before the race, halfway through the race, upon finishing the race and after recovery (+48 h). Blood biomarker levels were also measured. A significant decrease in the quadriceps shear modulus was observed upon finishing the race (3.31±0.61 kPa) (p<0.001) compared to baseline (3.56±0.63 kPa), followed by a partial recovery +48 h after the race (3.45±0.6 kPa) (p = 0.002) across all muscle heads, as well as for each of the following three muscle heads: the rectus femoris (p = 0.003), the vastus medialis (p = 0.033) and the vastus lateralis (p = 0.001). Our study is the first to assess changes in muscle stiffness during prolonged extreme physical endurance exercises based on shear modulus measurements using non-invasive SWE. We concluded that decreases in stiffness, which may have resulted from quadriceps overuse in the setting of supra-physiological stress caused by the extreme distance and unique elevation of the race, may have been responsible for the development of inflammation and muscle swelling. SWE may hence represent a promising tool for monitoring physiologic or pathological variations in muscle stiffness and may be useful for diagnosing and monitoring muscle changes.

1 March 2016 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
LBLoic Belle
Loic Belle
PMPascal Motreff
Pascal Motreff
LMLionel Mangin
Lionel Mangin
GRGrégoire Rangé
Grégoire Rangé
XMXavier Marcaggi
Xavier Marcaggi
OIon behalf of the MIMI Investigators
on behalf of the MIMI Investigators
Background—: Delayed stent implantation after restoration of normal epicardial flow by a minimalist immediate mechanical intervention aims to decrease the rate of distal embolization and impaired myocardial reperfusion after percutaneous coronary intervention. We sought to confirm whether a delayed stenting (DS) approach (24–48 hours) improves myocardial reperfusion, versus immediate stenting, in patients with acute ST-segment–elevation myocardial infarction undergoing primary percutaneous coronary intervention. Methods and Results—: In the prospective, randomized, open-label minimalist immediate mechanical intervention (MIMI) trial, patients (n=140) with ST-segment–elevation myocardial infarction ≤12 hours were randomized to immediate stenting (n=73) or DS (n=67) after Thrombolysis In Myocardial Infarction 3 flow restoration by thrombus aspiration. Patients in the DS group underwent a second coronary arteriography for stent implantation a median of 36 hours (interquartile range 29–46) after randomization. The primary end point was microvascular obstruction (% left ventricular mass) on cardiac magnetic resonance imaging performed 5 days (interquartile range 4–6) after the first procedure. There was a nonsignificant trend toward lower microvascular obstruction in the immediate stenting group compared with DS group (1.88% versus 3.96%; P =0.051), which became significant after adjustment for the area at risk ( P =0.049). Median infarct weight, left ventricular ejection fraction, and infarct size did not differ between groups. No difference in 6-month outcomes was apparent for the rate of major cardiovascular and cerebral events. Conclusions—: The present findings do not support a strategy of DS versus immediate stenting in patients with ST-segment–elevation infarction undergoing primary percutaneous coronary intervention and even suggested a deleterious effect of DS on microvascular obstruction size. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01360242.