Nobuyuki Takeuchi

Dr. Nobuyuki Takeuchi


Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NTNobuyuki Takeuchi
Nobuyuki Takeuchi
SSShunsuke Sugiyama
Shunsuke Sugiyama
KIKoji Inui
Koji Inui
KKKousuke Kanemoto
Kousuke Kanemoto
MNMakoto Nishihara
Makoto Nishihara
Sensory gating is a mechanism of sensory processing used to prevent an overflow of irrelevant information, with some indexes, such as prepulse inhibition (PPI) and P50 suppression, often utilized for its evaluation. In addition, those are clinically important for diseases such as schizophrenia. In the present study, we investigated long-latency paired-pulse suppression of change-related cortical responses using magnetoencephalography. The test change-related response was evoked by an abrupt increase in sound pressure by 15 dB in a continuous sound composed of a train of 25-ms pure tones at 65 dB. By inserting a leading change stimulus (prepulse), we observed suppression of the test response. In Experiment 1, we examined the effects of conditioning-test intervals (CTI) using a 25-ms pure tone at 80 dB as both the test and prepulse. Our results showed clear suppression of the test response peaking at a CTI of 600 ms, while maximum inhibition was approximately 30%. In Experiment 2, the effects of sound pressure on prepulse were examined by inserting prepulses 600 ms prior to the test stimulus. We found that a paired-pulse suppression greater than 25% was obtained by prepulses larger than 77 dB, i.e., 12 dB louder than the background, suggesting that long latency suppression requires a relatively strong prepulse to obtain adequate suppression, different than short-latency paired-pulse suppression reported in previous studies. In Experiment 3, we confirmed similar levels of suppression using electroencephalography. These results suggested that two identical change stimuli spaced by 600 ms were appropriate for observing the long-latency inhibition. The present method requires only a short inspection time and is non-invasive.

26 June 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NTNobuyuki Takeuchi
Nobuyuki Takeuchi
SSShunsuke Sugiyama
Shunsuke Sugiyama
KIKoji Inui
Koji Inui
KKKousuke Kanemoto
Kousuke Kanemoto
MNMakoto Nishihara
Makoto Nishihara
Sensory suppression is a mechanism that attenuates selective information. As for long-latency suppression in auditory and somatosensory systems, paired-pulse suppression, observed as 2 identical stimuli spaced by approximately 500 ms, is widely known, though its mechanism remains to be elucidated. In the present study, we investigated the relationship between auditory and somatosensory long-latency suppression of change-related cortical responses using magnetoencephalography. Somatosensory change-related responses were evoked by an abrupt increase in stimulus strength in a train of current-constant square wave pulses at 100 Hz to the left median nerve at the wrist. Furthermore, auditory change-related responses were elicited by an increase in sound pressure by 15 dB in a continuous sound composed of a train of 25-ms pure tones. Binaural stimulation was used in Experiment 1, while monaural stimulation was used in Experiment 2. For both somatosensory and auditory stimuli, the conditioning and test stimuli were identical, and inserted at 2400 and 3000 ms, respectively. The results showed clear suppression of the test response in the bilateral parisylvian region, but not in the postcentral gyrus of the contralateral hemisphere in the somatosensory system. Similarly, the test response in the bilateral supratemporal plane (N100m) was suppressed in the auditory system. Furthermore, there was a significant correlation between suppression of right N100m and right parisylvian activity, suggesting that similar mechanisms are involved in both. Finally, a high test-retest reliability for suppression was seen with both modalities. Suppression revealed in the present study is considered to reflect sensory inhibition ability in individual subjects.

22 August 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TKTomoaki Kinukawa
Tomoaki Kinukawa
NTNobuyuki Takeuchi
Nobuyuki Takeuchi
SSShunsuke Sugiyama
Shunsuke Sugiyama
MNMakoto Nishihara
Makoto Nishihara
KNKimitoshi Nishiwaki
Kimitoshi Nishiwaki
KIKoji Inui
Koji Inui
We used auditory-evoked magnetic fields to investigate the properties of echoic memory. The sound stimulus was a repeated 1-ms click at 100 Hz for 500 ms, presented every 800 ms. The phase of the sound was shifted by inserting an interaural time delay of 0.49 ms to each side. Therefore, there were two sounds, lateralized to the left and right. According to the preceding sound, each sound was labeled as D (preceded by a different sound) or S (by the same sound). The D sounds were further grouped into 1D, 2D, and 3D, according to the number of preceding different sounds. The S sounds were similarly grouped to 1S and 2S. The results showed that the preceding event significantly affected the amplitude of the cortical response; although there was no difference between 1S and 2S, the amplitudes for D sounds were greater than those for S sounds. Most importantly, there was a significant amplitude difference between 1S and 1D. These results suggested that sensory memory was formed by a single sound, and was immediately replaced by new information. The constantly-updating nature of sensory memory is considered to enable it to act as a real-time monitor for new information.

1 September 2021 in Neuroscience Research
Verified
Journal Article
Closed access
NTNobuyuki Takeuchi
Nobuyuki Takeuchi
TKTomoaki Kinukawa
Tomoaki Kinukawa
SSShunsuke Sugiyama
Shunsuke Sugiyama
KIKoji Inui
Koji Inui
MNMakoto Nishihara
Makoto Nishihara

1 January 2017 in Case Reports in Psychiatry
Verified
Journal Article
Open access
PDF file
NTNobuyuki Takeuchi
Nobuyuki Takeuchi
EKEtushi Kato
Etushi Kato
KKKousuke Kanemoto
Kousuke Kanemoto
We report here a patient in whom the effects of a cerebellum mass may have led to development of obsessive‐compulsive disorder (OCD). A 33‐year‐old woman showed symptoms of OCD, including obsessive worry about infection from tainted blood and repetitive confirmation, which worsened during pregnancy. She had comprehension in regard to her illness and no evidence of cognitive dysfunction and did not meet other DSM‐5 criteria such as depression. One month after giving childbirth, the symptoms worsened, while headache and dizziness also developed. The Yale‐Brown Obsessive‐Compulsive Scale (Y‐BOCS) score was 34. The patient was examined for a headache and a posterior cranial fossa meningioma was found. Following resection of the meningioma, the OCD symptoms were remarkably reduced (Y‐BOCS score 10). There is only one previous report of pure OCD associated with a cerebellar mass and the present findings should help to elucidate the mechanism.

26 August 2020 in Human Brain Mapping
Verified
Journal Article
Open access
PDF file
SSShunsuke Sugiyama
Shunsuke Sugiyama
TKTomoaki Kinukawa
Tomoaki Kinukawa
NTNobuyuki Takeuchi
Nobuyuki Takeuchi
MNMakoto Nishihara
Makoto Nishihara
TSToshiki Shioiri
Toshiki Shioiri
KIKoji Inui
Koji Inui
Haptic memory briefly retains somatosensory information for later use; however, how and which cortical areas are affected by haptic memory remain unclear. We used change‐related cortical responses to investigate the relationship between the somatosensory cortex and haptic memory objectively. Electrical pulses, at 50 Hz with a duration of 500 ms, were randomly applied to the second, third, and fourth fingers of the right and left hands at an even probability every 800 ms. Each stimulus was labeled as D (preceded by a different side) or S (preceded by the same side). The D stimuli were further classified into 1D, 2D, and 3D, according to the number of different preceding stimuli. The S stimuli were similarly divided into 1S and 2S. The somatosensory‐evoked magnetic fields obtained were divided into four components via a dipole analysis, and each component's amplitudes were measured using the source strength waveform. The results showed that the preceding event did not affect the amplitude of the earliest 20–30 ms response in the primary somatosensory cortex. However, in the subsequent three components, the cortical activity amplitude was largest in 3D, followed by 2D, 1D, and S. These results indicate that such modulatory effects occurred somewhere in the somatosensory processing pathway higher than Brodmann's area 3b. To the best of our knowledge, this is the first study to demonstrate the existence of haptic memory for somatosensory laterality and its impact on the somatosensory cortex using change‐related cortical responses without contamination from peripheral effects.