In Korea, radiant floor heating systems are commonly used in residential buildings, even high-rise houses. If these existing radiant floor heating panels could be used for cooling as well, additional...
The packaged terminal air conditioning with reheat (PTACR) system, as a commonly used dehumidification system, faces the problem of extra energy consumption in the deep-cooling and reheating processes. Therefore, different heat pump assisted hybrid solid desiccant cooling (HPDC) systems were proposed and their characteristics were investigated via EnergyPlus simulations. The system energy efficiency presents an upward trend with the increase in outdoor temperature and humidity. A high-humidity climate leads to the improvement of system performance. The dehumidification performance of the desiccant wheel in the HPDC system declines when outdoor humidity increases. Compared with the PTACR system, the energy consumption of the HPDC system in which the evaporator was placed upstream of the desiccant wheel is reduced by 36%, 66%, and 64%, respectively, under different high-humidity climates. The system maintained the indoor environment within the comfort zone, and eliminated the need for a heat source for desiccant regeneration. In conclusion, the HPDC system is an available alternative that considers both energy consumption and system performance. Placing the evaporator upstream of the desiccant wheel is more advantageous in high-temperature and high-humidity climates.
6 June 2022 in Case Studies in Thermal Engineering
This study was conducted to derive the amount of energy savings when applying the method of making the load similar by changing the set temperature of the room in the building to which the simultaneous heating and cooling (SHC) system is applied. Energy savings were derived through theoretical analysis and comparisons through static simulations were performed to verify the proposed method. As a result, the energy savings are proportional to the energy limit that can be additionally input to the SHC and is proportional to the ratio of the coefficient of performance (COP) difference between the SHC and auxiliary heat source and the auxiliary heat source COP. That is, to increase the amount of energy savings, the maximum possible energy should be input for the SHC, or the SHC COP must be greater than the auxiliary heat source COP. In addition, comfort can be achieved stably by varying the set room temperature in a room with a small load. When a heat storage tank is installed or changing the indoor set temperature of both the hot and cold zones in real time by predicting the indoor load is possible, more energy can be saved.
5 February 2015 in Building Services Engineering Research & Technology
The purpose of this study is to make the target condition of experimental assessment based on the standard EN1264. To achieve this purpose, the characteristic errors, which are caused by characteristics of experimental setup and prevent the results from meeting the target condition, should be removed. This study proposes an experimental setup and suggests a control strategy based on standard EN1264. For the specifications of the experimental setup, the essential equipment and the configuration of the heat production system were deduced. For a proper control strategy, possible control strategies were derived by investigating the control-related factors such as reference points and control algorithms, and the most proper control strategy was validated by experimental assessment. Practical application: This study presents an experimental assessment to evaluate the thermal output of radiant floor heating systems based on the standard EN1264 referenced by ISO11855-2:2012. The proposed experimental assessment method will be able to supplement ISO11855-2:2012 and contribute to the development of thermally effective radiant heating panels. Therefore, it is expected that the results will be helpful to researchers for indoor environment, heating, ventilating, and air conditioning engineers, system manufacturers, and those who want to analyze the thermal output of radiant floor heating panels based on ISO 11855-2:2012.