Lorenzi Banci

Mr. Lorenzi Banci

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
AGAntonio Pompilio Gigante
Antonio Pompilio Gigante
CBCarlo Bottegoni
Carlo Bottegoni
VRVincenza Ragone
Vincenza Ragone
LBLorenzi Banci
Lorenzi Banci
Since polyethylene is one of the most frequently used biomaterials, such as in bearing components in joint arthroplasty, strong efforts have been made to improve the design and material properties over the last decades. Antioxidants, such as vitamin-E, seem to be a promising alternative to further increase durability and reduce polyethylene wear and degradation in the long-term. Nevertheless, even if several promising in vitro results are available, there is yet no clinical evidence that vitamin-E polyethylenes show these advantages in vivo. The aim of this paper was to provide a comprehensive overview on the current knowledge regarding the biological and mechanical proprieties of this biomaterial, underlying the in vitro and in vivo evidence for effectiveness of vitamin-E-doped polyethylene in joint arthroplasty.

13 August 2023 in Materials
Verified
Journal Article
Open access
PDF file
AGAllegra Galas
Allegra Galas
LBLorenzi Banci
Lorenzi Banci
Bernardo InnocentiBernardo Innocenti
Bernardo Innocenti
Due to the high stiffness of the biomaterials used in total knee arthroplasty, stress shielding can lead to decreased periprosthetic bone mineral density and bone resorption. As different materials and 3D-printed highly porous surfaces are available for knee femoral components from the industry nowadays, this study aimed to compare the effects of two same-design cruciate-retaining femoral components, made with CoCr and titanium alloy, respectively, on periprosthetic bone stresses through a finite element model of the implanted knee in order to evaluate the induced stress shielding. Moreover, the effect of the cementless highly porous surface of the titanium implant was analyzed in comparison to the cemented interface of the CoCr implant. The von Mises stresses were analyzed in different periprosthetic regions of interest of the femur with different configurations and knee flexion angles. The titanium component induced higher bone stresses in comparison with the CoCr component, mostly in the medial compartment at higher knee flexion angles; therefore, the CoCr component led to more stress shielding. The model was revealed to be effective in describing the effects of different femoral component materials on bone stress, highlighting how a cementless, highly porous titanium femoral component might lead to less stress shielding in comparison to a cemented CoCr implant with significant clinical relevance and reduced bone resorption after total knee arthroplasty.

20 April 2022 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
DTDomenico Tigani
Domenico Tigani
LBLorenzi Banci
Lorenzi Banci
RVRiccardo Valtorta
Riccardo Valtorta
LALuca Amendola
Luca Amendola
Background: Use of dual mobility (DM) in total hip arthroplasty has gained popularity due to the ability to reduce dislocation through increased jumping distance and impingement-free arc of movement. Recently, modular dual mobility (modDM) systems were introduced to give the possibility to use DM with standard metal-backed shells, however few has been studied to date regarding how jumping distance and the center of rotation change with modDM. The objective of this study was to evaluate, through analytical simulation, how jumping distance, center of rotation and arc of movement change between DM and standard cups with modDM or fixed bearings (FB). Methods: 3D-models of DM and standard press-fit cups with modDM or FB liners were used to simulate DM, modDM and FB implant configurations, matched for same cup size, according to same cup position and different femoral head diameters. Jumping distance was calculated and center of rotation lateralization and oscillation angles were measured for each size of these three implant configurations. Results: Jumping distance with modDM was reduced by -3.9 mm to -8.6 mm in comparison with DM, from 48 to 64 mm size, but resulted comparable to polyethylene 36 mm FB and increased by + 1.1 mm and + 1.4 mm than ceramic 36 and 40 mm FBs for sizes > 54 mm. ModDM lateralized the center of rotation up to + 2.5 mm and + 4.0 mm in comparison with DM and FBs, respectively. Oscillation angle with modDM resulted higher than + 16°, + 23°, + 17° and + 14° in comparison to DM, 28 mm, 32 mm and 36 mm FB cups, respectively, for 56 mm cup size. Conclusions: According to its specific design, modDM might change hip stability parameters in comparison to DM, worsening jumping distance and center of rotation position, but increasing arc of movement. As not restoring stability parameters in the same fashion, modDM implants should be properly used when DM cups are not feasible.

Verified
Journal Article
Open access
PDF file
VCVincenzo Ciriello
Vincenzo Ciriello
RCRoberta La China
Roberta La China
DCDanilo Francesco Chirillo
Danilo Francesco Chirillo
GBGiuseppe Bianco
Giuseppe Bianco
FFFederico Fusini
Federico Fusini
LPLucio Piovani
Lucio Piovani
Background: Dual mobility (DM) has been proven to reduce dislocation risk after total hip arthroplasty (THA). In the last decade modular DM (modDM) constructs have been introduced to allow the use of DM articulation with standard cementless acetabular shells. However, clinical evidence of modDM effectiveness is still low in primary THA and concerns about implant-related complications are increasing. This retrospective comparative multicenter study is aimed to investigate if the dislocation rate after primary THA could be reduced with modDM in comparison to standard bearing (SB). Methods: 262 THAs were performed between 2017 and 2019, using SB (129 hips) or modDM (133) with the same cementless highly porous modular acetabular cup. Dislocations, complications and revisions were recorded and implant survival was analyzed. Results: At 2.5-year mean follow-up, dislocation occurred in 4 hips (3.1%) within the SB group while intraprosthetic dislocation in 2 hips (1.5%) within the modDM group (p = 0.44). Implant survivals with revision due to dislocation were 95.2% and 95.9% at 4-year follow-up for SB and modDM, respectively (p = 0.50). Conclusions: modDM used in primary THA might reduce dislocation rate in comparison to SB, even in high-risk patients, however, caution is advocated due to specific intraprosthetic dislocation.

29 October 2021 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
LBLorenzi Banci
Lorenzi Banci
GBGiovanni Balato
Giovanni Balato
PSPaolo Salari
Paolo Salari
ABAndrea Baldini
Andrea Baldini

15 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
NPNicola Piolanti
Nicola Piolanti
ENElisabetta Neri
Elisabetta Neri
EBEnrico Bonicoli
Enrico Bonicoli
PPPaolo Domenico Parchi
Paolo Domenico Parchi
SMStefano Marchetti
Stefano Marchetti
MSMichelangelo Scaglione
Michelangelo Scaglione
Background: Although cementless implants are increasing in popularity, the use of cementless femoral stems for total hip arthroplasty (THA) and hip hemiarthroplasty (HH) in elderly patients remains controversial. The aim of this study was to report the outcomes of a cementless stem used in a large multicentric cohort of elderly patients receiving elective THA and HH for displaced femoral neck fracture. Methods: A total of 293 patients (301 hips) aged 70 years or older (mean age, 78 years; range, 70–93) who received the same cementless plasma-sprayed porous titanium–hydroxyapatite stem were retrospectively evaluated after primary THA and HH to investigate stem survival, complications, and clinical and radiographic results. Results: Cumulative stem survival was 98.5% (95% CI, 96.4–99.4%; 91 hips at risks) with revision due to any reason as the end-point at 10-year follow-up (mean 8.6 years, range 4–12). No stem was revised due to aseptic loosening. The mean Forgotten Joint Score was 98.7. Radiographically, the implants showed complete osseointegration, with slight stress-shieling signs in less than 10% of the hips. Conclusion: The use of cementless stems was proven to be a reliable and versatile option even in elderly patients for elective THA and HH for femoral neck fracture.