MARIA CUESTA RUIZ

Dr. MARIA CUESTA RUIZ

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2004 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
Pedro CoboPedro Cobo
Pedro Cobo
JPJaime Pfretzschner
Jaime Pfretzschner
MARIA CUESTA RUIZMARIA CUESTA RUIZ
MARIA CUESTA RUIZ
DADavid K. Anthony
David K. Anthony
A theoretical and experimental study of a proposed hybrid passive–active plane-wave system to provide broadband acoustic absorption is presented. The passive absorber consists of a microperforated panel (MPP), used in place of conventional fibrous materials, in front of an air layer. The active system uses an active transducer (a loudspeaker), an error sensor (a microphone), and an adaptive controller. MPPs are thinner than fibrous materials and provide a better solution in hygienic environments. For two such systems, the dependence of performance on MPP parameters is studied for two control strategies: impedance matching and pressure release. The first condition is found to be better for cases where the acoustic impedance of the system approaches that of air. Otherwise, the pressure-release condition is better, and a wideband solution is the implementation of the active control system up to a frequency where the natural band of the passive system provides higher absorption. Therefore, the use of a low-pass filter in the error signal is implemented to afford hybrid passive–active wideband absorption. The control effort of active system is also considered. Experimental verification shows good agreement with theory, and an average absorption coefficient of 0.82 in the frequency bandwidth 100 to 1600 Hz was achieved.

1 November 2006 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
NSN. Sellen
N. Sellen
MARIA CUESTA RUIZMARIA CUESTA RUIZ
MARIA CUESTA RUIZ
MGM.-A. Galland
M.-A. Galland

1 January 2006 in Applied Acoustics
Verified
Journal Article
Closed access
JPJaime Pfretzschner
Jaime Pfretzschner
Pedro CoboPedro Cobo
Pedro Cobo
FSFrancisco Simón
Francisco Simón
MARIA CUESTA RUIZMARIA CUESTA RUIZ
MARIA CUESTA RUIZ
AFAlejandro Fernández
Alejandro Fernández

26 December 2022 in Audiology Research
Verified
Journal Article
Open access
PDF file
MLMarta Fernández Ledesma
Marta Fernández Ledesma
MARIA CUESTA RUIZMARIA CUESTA RUIZ
MARIA CUESTA RUIZ
RSRicardo Sanz-Fernández
Ricardo Sanz-Fernández
Pedro CoboPedro Cobo
Pedro Cobo
Background: Tinnitus is an audiological disorder for which there are no objective measuring tools. Thus, many self-report questionnaires have been proposed to assess its severity. These questionnaires have been judged for their capacity to assess the tinnitus severity at baseline, their sensitivity to treatment-related changes (responsiveness), and their resolution. Methods: The most widely used questionnaires for clinical and research studies are the Tinnitus Handicap Inventory (THI) and the Tinnitus Functional Index (TFI). While both questionnaires have been recognized as good evaluators of the baseline tinnitus severity, the latter is considered to be more responsive to changes following treatments. Objectives: The aim of this work is to provide a preliminary comparison of the performance of both questionnaires in the initial and final tinnitus severity assessment of a cohort of patients undergoing a four-month Enriched Acoustic Environment (EAE) therapy. Results: The EAE therapy provided a 30 and 26 point reduction in THI and TFI, respectively. A good correlation is obtained between the THI and TFI questionnaires at baseline and after the treatment. Conclusion: At baseline, the THI provided a higher score than the TFI for a higher degree of tinnitus but a lower score for lower tinnitus severity. Both THI and TFI were good questionnaires for baseline assessment and for treatment-related changes. The THI provided a slightly higher score drop than the TFI following the treatment, although the TFI had better resolution.

6 January 2022 in Brain Sciences
Verified
Journal Article
Open access
PDF file
MARIA CUESTA RUIZMARIA CUESTA RUIZ
MARIA CUESTA RUIZ
CGChristiam Garzón
Christiam Garzón
Pedro CoboPedro Cobo
Pedro Cobo
Background: Tinnitus is a rather heterogeneous chronic condition/disorder which is difficult to treat. Some tinnitus treatments combine sound therapy with counselling. The main goal of this study is to report the efficacy of a customized sound therapy combined with counselling on a cohort of 83 tinnitus patients. Methods: 119 tinnitus subjects, recruited between January 2018 and June 2021, were subjected to a treatment consisting of a combination of an initial counselling session and four-month sound therapy. The sound stimulus was a personalized broadband noise colored by the audiometry of the subjects. These stimuli were given to the patients in mp3 format to be heard 1 h per day over 4 months. The tinnitus severity of the patients was evaluated monthly through the validated Spanish version of the Tinnitus Handicap Inventory. Results: Of the patients, 30% (36 of 119) withdrew from the treatment before finishing, and 96% (80 of 83) of the subjects completing the therapy attained some relief after 4 months. The overall average THI decrease of these 80 participants was 23. However, when the THI was analyzed by severity scales, it was found that patients with initial mild, moderate, severe and catastrophic handicap had an average THI decrease of 14, 20, 31 and 42 points, respectively. Thus, the average THI decrease depended on the baseline severity scale of patients. Conclusions: Consequently, the proposed treatment was demonstrated to be effective in providing clinically relevant relief in tinnitus distress patients in just 4 months.

16 May 2007 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
Pedro CoboPedro Cobo
Pedro Cobo
MARIA CUESTA RUIZMARIA CUESTA RUIZ
MARIA CUESTA RUIZ
Although hybrid passive-active absorption in impedance tubes has been widely analyzed, its study in more realistic conditions remains to be accomplished. This letter describes the practical measurement of the passive-active absorption coefficient in a free field. The passive absorber consists of a microperforated panel backed by an air cavity and a wooden panel. A multichannel active system controls the sound pressure in a reduced cell behind the absorber. Measured absorption coefficients between 200 and 400Hz account for 0.2–0.4 and 0.72–0.75, in the passive and active cases, respectively, and above 500Hz both are comparable.