Chia-Yu Chen

Dr. Chia-Yu Chen

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

24 October 2022 in Journal of Periodontology
Verified
Journal Article
Open access
GAGustavo Avila-Ortiz
Gustavo Avila-Ortiz
JAJeanne Ambruster
Jeanne Ambruster
SBShayan Barootchi
Shayan Barootchi
LCLeandro Chambrone
Leandro Chambrone
CCChia-Yu Chen
Chia-Yu Chen
BMBrian L. Mealey
Brian L. Mealey
A biologic is a therapeutic agent with biological activity that is administered to achieve an enhanced regenerative or reparative effect. The use of biologics has progressively become a core component of contemporary periodontal practice. However, some questions remain about their safety, indications, and effectiveness in specific clinical scenarios. Given their availability for routine clinical use and the existing amount of related evidence, the goal of this American Academy of Periodontology (AAP) best evidence consensus (BEC) was to provide a state‐of‐the‐art, evidence‐based perspective on the therapeutic application of autologous blood‐derived products (ABPs), enamel matrix derivative (EMD), recombinant human platelet‐derived growth factor BB (rhPDGF‐BB), and recombinant human bone morphogenetic protein 2 (rhBMP‐2). A panel of experts with extensive knowledge on the science and clinical application of biologics was convened. Three systematic reviews covering the areas of periodontal plastic surgery, treatment of infrabony defects, and alveolar ridge preservation/reconstruction and implant site development were conducted a priori and provided the foundation for the deliberations. The expert panel debated the merits of published data and exchanged experiential information to formulate evidence‐based consensus statements and recommendations for clinical practice and future research. Based on an analysis of the current evidence and expert opinion, the panel concluded that the appropriate use of biologics in periodontal practice is generally safe and provides added benefits to conventional treatment approaches. However, therapeutic benefits and risks range based on the specific biologics used as well as patient‐related local and systemic factors. Given the limited evidence available for some indications (e.g., gingival augmentation therapy, alveolar ridge preservation/reconstruction, and implant site development), future clinical studies that can expand the knowledge base on the clinical use of biologics in periodontal practice are warranted.

4 November 2020 in Prosthesis
Verified
Journal Article
Open access
PDF file
KSKelly Suralik
Kelly Suralik
JSJie Sun
Jie Sun
CCChia-Yu Chen
Chia-Yu Chen
SLSang Lee
Sang Lee
There has been an increase in utilizing 3D printers in dental restorations. The purpose of the study is to compare mechanical properties of 3D-printed prostheses to those of self-cured and/or computer-aided design-computer-aided manufacturing (CAD-CAM) restorations. A metal master typodont was prepared for the mandibular left sextant with implant analogs embedded at the first premolar and first molar positions with a missing second premolar. Three-unit provisional fixed dental prosthesis (FDP) was designed utilizing the 3Shape tooth library and forty-five uniform specimens were fabricated with different materials: self-cured poly(methyl methacrylate) (PMMA) (N = 15), milled PMMA CAD-CAM blocks (N = 15) and 3D-printed resin (N = 15). All specimens were tested using an Instron machine at a crosshead speed of 0.5 mm/min by an axial load on the occlusal surface of the second premolar pontic site. Statistical analysis was completed with Shapiro-Wilk, ANOVA and Tukey post-hoc tests. Mean fracture force was 300.61 N, 294.64 N and 408.49 N for self-cured PMMA, milled PMMA and 3D-printed resin, respectively. Mean force at FDP fracture of 3D-printed resin was significantly greater than the mean fracture force of either self-cured (p = 0.016, 95% CI [17.86, 197.91]) or milled (p = 0.010, 95% CI [23.83, 203.88]) PMMA.

9 January 2024 in Journal of Periodontology
Verified
Journal Article
Open access
KMKathleen Chloe Mascardo
Kathleen Chloe Mascardo
JTJustin Tomack
Justin Tomack
CCChia-Yu Chen
Chia-Yu Chen
LMLeonardo Mancini
Leonardo Mancini
DKDavid M. Kim
David M. Kim
LTLorenzo Tavelli
Lorenzo Tavelli
Background: To evaluate the risk indicators associated with midfacial gingival recessions (GR) in the natural dentition esthetic regions.Methods: Cone‐beam computed tomography (CBCT) results of thirty‐seven subjects presenting with 268 eligible teeth were included in the cross‐sectional study. Clinical measurements included presence/absence of midfacial GR; the depth of the midfacial, mesial, and distal gingival recession; the recession type (RT); keratinized tissue width (KT); and attached gingiva width (AG). Questionnaires were utilized to capture patient‐reported esthetics and dental hypersensitivity for each study tooth. Buccal bone dehiscence (cBBD) and buccal bone thickness (cBBT) were measured on the CBCT scans. High‐frequency ultrasonography was performed to assess gingival thickness (GT) and buccal bone dehiscence (uBBD). Intraoral optical scanning was obtained to quantify the buccolingual position of each study site (3D profile analysis). Multilevel logistic regression analyses with generalized estimation equations were performed to assess the factors associated with the conditions of interest.Results: The presence of midfacial GR was significantly associated with the history of periodontal treatment for pocket reduction (OR 7.99, p = 0.006), KT (OR 0.62, p < 0.001), cBBD (OR 2.30, p = 0.015), GT 1.5 mm from the gingival margin (OR 0.18, p = 0.04) and 3D profile 1 mm from the gingival margin (OR 1.04, p = 0.001). The depth of midfacial GR was significantly correlated to previous history of periodontal treatment (OR 0.96, p = 0.001), KT (OR −0.18, p < 0.001), presence of bone fenestration (OR 0.24, p = 0.044), and cBBD (OR 0.43, p < 0.001). The depth of midfacial GR was also the only factor associated with patient‐reported esthetics (OR −3.38, p = 0.022), while KT (OR 0.77, p = 0.018) and AG (OR 0.82, p = 0.047) were significantly correlated with patient‐reported dental hypersensitivity.Conclusions: Several risk indicators of midfacial and interproximal GR in the esthetic region were identified. The use of imaging technologies allowed for detection of parameters associated with the conditions of interest, and, therefore, their incorporation in future clinical studies is advocated. Ultrasonography could be preferred over CBCT for a noninvasive assessment of periodontal phenotype.

11 October 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
MNMyron Nevins
Myron Nevins
CCChia-Yu Chen
Chia-Yu Chen
SPStephano Parma-Benfenati
Stephano Parma-Benfenati
DKDavid M. Kim
David M. Kim
Recent technological advancements led to the development of various plasma-based technologies for post-packaging modifications. The purpose of the present preclinical in vivo study was to assess the safety and efficacy of a novel chairside nonthermal gas plasma treatment for enhancing osseointegration of titanium implants. Six male mixed foxhounds underwent extraction of mandibular premolars and first molars, and the sockets healed for 42 days. Canine mandibles were randomized to receive either plasma-treated (test) or non-plasma-treated (control) dental implants. A total of 36 implants were placed in six animals, and they were sacrificed at 2 weeks (two animals), 4 weeks (two animals), and 6 weeks (two animals) after the implant surgery. When the radiographic analysis was performed, the changes in bone level were not statistically significant between the two groups at 2 weeks and 4 weeks. The difference became significant at 6 weeks (p = 0.016), indicating more bone loss from baseline to 6 weeks for the control group. The bone-to-implant contact (BIC) appeared to be higher for the test groups at all time points, and the BIC was significantly higher for the test group at 4 weeks (p = 0.046). In conclusion, this study underscored the potential of nonthermal plasma treatment in enhancing implant osseointegration.

4 April 2022 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
KHKailing Ho
Kailing Ho
SBShaima Bahammam
Shaima Bahammam
CCChia-Yu Chen
Chia-Yu Chen
YHYasushi Hojo
Yasushi Hojo
DKDavid Kim
David Kim
SNShigemi Nagai
Shigemi Nagai
Background: This study aimed to collect data regarding patient perception and knowledge of dental implants. It was conducted with the hope that the data would provide dental professionals and policymakers with a better understanding of ways to promote implant therapy. Methods: An anonymous online survey with 10 questions was distributed through 12 dental offices in Tokyo and provincial cities in Japan to assess patient perception and knowledge of dental implants. Harvard Medical School’s IRB approved this study. Results: We collected data from 1172 patients (59% female, 41% male). The most common perceptions of implant therapy were that it was “expensive,” “advanced,” and “scary”. Patients’ implant knowledge came primarily from magazines or books, while professional dental societies/associations were the least sought out source of information. Patients believed that the purpose of dental implants was to avoid dentures and improve chewing function. Their primary concerns about dental implants were the cost and longevity. Approximately 12% of patients with dental implants and 61% of patients without implants did not know that bone grafts may be required and that sedation during surgery was an option. For patients who experienced sedation during the procedure, 60% of them want it for future surgeries. Patients also had limited knowledge of bone-graft materials and the effects of CBCT radiation; 75% of the patients expressed concerns over the safety of graft materials and radiation exposure. For patients with a history of dental implant therapy, 80% of them would recommend dental implants to their family and friends. Conclusions: Overall, patients’ experiences with dental implant therapy were positive, but there was a lack of patient education regarding dental implants and their associated procedures. Dental professionals need to take the initiative to improve patient education.