Mustapha Errouha

Dr. Mustapha Errouha

Laboratory of Plasma and Energy Conversion (LAPLACE), University of Toulouse, 31000 Toulouse, France
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2018 in Energy Science & Engineering
Verified
Journal Article
Open access
PDF file
OZOthmane Zamzoum
Othmane Zamzoum
YMYouness EL MOURABIT
Youness EL MOURABIT
Mustapha ErrouhaMustapha Errouha
Mustapha Errouha
ADAziz Derouich
Aziz Derouich
AGAbdelaziz El Ghzizal
Abdelaziz El Ghzizal
The main objective of this study is to improve the energy quality extracted by variable speed wind turbine based on doubly fed induction generator. First, the dynamic modeling of different parts of the system is presented. The electrical machine is modeled in PARK reference frame. Thereafter, the control technique is detailed. Indirect field‐oriented control with fuzzy logic controllers (FLC) is used to control the rotor currents and consequently the real and reactive powers of the stator generator. Then, the design of FLC is detailed by tuning its most significant parameters, which are scaling factor rules base and membership functions. Finally, a simulation using the MATLAB/SIMULINK environment is carried out to prove the validation of the control strategy using a 2 MW wind turbine. The results show a satisfactory performance in terms of rapidity, stability, and precision under variable wind speed conditions.

18 August 2020 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
Mustapha ErrouhaMustapha Errouha
Mustapha Errouha
ADAziz Derouich
Aziz Derouich
Najib El OuanjliNajib El Ouanjli
Najib El Ouanjli
Saad MotahhirSaad Motahhir
Saad Motahhir
This work is aimed at achieving a simple and reduced-cost configuration of photovoltaic (PV) water pumping system (PVWPS) using an induction motor with high efficiency. The proposed PV system is composed of two stages of converters which the first one ensures the maximum power point by controlling the duty ratio of boost converter using variable step size incremental conductance (VSS INC) technique. Fuzzy logic control based on direct torque control is proposed to serve the purpose of operating an induction motor. Moreover, the combining of these proposed control strategies has been never discussed. The proposed control scheme is modeled and simulated in detail under MATLAB/Simulink software to evaluate its performance under fast variations of irradiance and daily climatic profile. The obtained simulation results using the suggested control strategies are compared to those using the most used method in the literature (variable step size perturb and observe (VSS P&O) algorithm). The simulation results indicate that the proposed PVWPS performed best in terms of the time of response; pumped water, flux ripples, and the stator currents are reduced.

18 March 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Mustapha ErrouhaMustapha Errouha
Mustapha Errouha
QCQuentin Combe
Quentin Combe
SMSaad Motahhir
Saad Motahhir
SAS. S. Askar
S. S. Askar
MAMohamed Abouhawwash
Mohamed Abouhawwash
In recent years, the improvement of photovoltaic water pumping system (PVWPS) efficiency takes the considerable interest of researchers due to its operating based on cleaner electrical energy production. In this paper, a new approach based on fuzzy logic controller incorporating loss minimization technique applied to the induction machine (IM) is developed for PVWPS applications. The proposed control selects the optimal flux magnitude by minimization of the IM losses. Moreover, Variable step size perturb and observe method is introduced. The suitability of the proposed control is approved by reducing the absorbed current; therefore, the motor losses are minimized and the efficiency is improved. The proposed control strategy is compared with the method without losses minimization. The comparison results illustrate the effectiveness of the proposed method based on losses minimization regarding the electrical speed, absorbed current, flow water and developed flux. A processor-in-the-loop (PIL) test is effectuated as an experimental test of the proposed method. It consists in implementing the generated C code on the STM32F4 discovery board. The obtained results from the embedded board are similar to numerical simulation results.

19 February 2020 in Technology and Economics of Smart Grids and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
Mustapha ErrouhaMustapha Errouha
Mustapha Errouha
ADAziz Derouich
Aziz Derouich
Saad MotahhirSaad Motahhir
Saad Motahhir
OZOthmane Zamzoum
Othmane Zamzoum

31 July 2024 in Irrigation Science
Verified
Journal Article
Closed access
PDF file
Mustapha ErrouhaMustapha Errouha
Mustapha Errouha
QCQuentin Combe
Quentin Combe
NONajib El Ouanjli
Najib El Ouanjli
SMSaad Motahhir
Saad Motahhir

1 December 2019 in Bulletin of Electrical Engineering and Informatics
Verified
Journal Article
Open access
PDF file
Mustapha ErrouhaMustapha Errouha
Mustapha Errouha
ADAziz Derouich
Aziz Derouich
In this papier, a low-cost solar photovoltaic water pumping system based on an induction motor without the use of chemical energy storage is presented. In literature, we can find several Maximum Power Point Tracking Algorithms, the choice of the algorithm is according to the nature of application. In this article, Variable Step Size Incremental Conductance MPPT method has been developed since it is fast and has less oscillations. The studied photovoltaic pumping system contains a centrifugal pump which is driven by a three-phase asynchronous motor. To control the water flow, the field-oriented control has been implemented. The control system is applied on two cities with different climatic conditions to evaluate their performance. The photovoltaic pumping system is developed using the MATLAB/Simulink software to discuss the results obtained. Consequently, the proposed MPPT based on the incremental conductance variable step shows good performances in terms of efficiency and tracking speed.