Hazal Kutlucan

Dr. Hazal Kutlucan

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in Life
Verified
Journal Article
Open access
PDF file
HKHazal Kutlucan
Hazal Kutlucan
RKRecep Onur Karabacak
Recep Onur Karabacak
SBStefanie De Buyser
Stefanie De Buyser
AEAhmet Erdem
Ahmet Erdem
NBNuray Bozkurt
Nuray Bozkurt
DWDirk Wildemeersch
Dirk Wildemeersch
The primary objective of this study was to assess the novel fixation method of a frameless copper-releasing intrauterine device inserted following placental delivery during cesarean section and analyze its impact in reducing device displacement and expulsion during and after uterine involution. We hypothesized that the dual-anchoring technique could reduce the risk of intrauterine device displacement and expulsion during and after the uterine involution. The study was conducted at the Gazi University Medicine Faculty Hospital in Ankara, Turkey. Twenty-one pregnant women were enrolled. Insertion was performed following placental removal. To confirm the proper placement and good retention of the device, the distance between the fundal serosa (S) and device anchor knot (A) was measured (S–A) during follow-ups, by ultrasound. There were significant differences in the S–A, as observed by ultrasound at discharge and at 6 weeks post-delivery, which is consistent with the tissue contractions associated with uterine involution. Notwithstanding the uterine involution, no device displacements or expulsions occurred, which indicated a good retention of the frameless device. This innovative retention method of the frameless intrauterine device ensures a well-tolerated, long-term contraception, allowing for immediate contraception and proper pregnancy spacing for cesarean scar healing, and overcomes the issue of expulsion encountered with conventional intrauterine systems.

1 January 2024 in TURKISH JOURNAL OF MEDICAL SCIENCES
Verified
Journal Article
Open access
PDF file
EDErhan Demi̇rDağ
Erhan Demi̇rDağ
HKHazal Kutlucan
Hazal Kutlucan
ATAnıl Doğukan Tutal
Anıl Doğukan Tutal
BKBi̇lGe Çalişkan Keski̇nSoy
Bi̇lGe Çalişkan Keski̇nSoy
GKGülşah Karakuyu
Gülşah Karakuyu
RKRecep Karabacak
Recep Karabacak
Background/aim: Cesarean section(CS) is a widely performed operation worldwide. Data about uterine closure is lacking. We aimed to evaluate scar niches and compare the single and double-layer uterine closure after six months following CS.Materials-Methods: A prospective, randomized trial assessed 56 women undergoing single or double-layer uterine closure. None of the patients had previous uterine surgery. The CSs were elective cases. Transvaginal ultrasound was performed six months after CS to assess uterine scar by measuring the width, depth, and length of scar niche and residual myometrial thickness. An experienced sonographer was blinded to the uterine closure technique and the ultrasounds were conducted as unaware of the technique in the postoperative follow-ups. Results: Twenty-eight cases were allocated to each single-layer closure (Group 1) and double-layer closure arm (Group 2). Demographic and clinical characteristics of patients, the width, depth, diameter of the niche, and residual myometrial thickness were similar among groups. There was no difference in uterine scar volume under incision between the two groups. The duration of surgery was about five minutes longer (p=0.048), and hemoglobin loss was about 0.5 g/dl less (p=0.039) in the double-layer group compared to the single-layer. Postmenstrual spotting rates were also similar among groups. Group 1 had two, and Group 2 had one spontaneous pregnancy within six months after CS.Conclusion: The single and double-layer closure techniques do not produce any different impacts on cesarean scar niche features after six months of delivery. In addition, ultrasound might be an important non-invasive diagnostic tool to understand CS scar remodeling.

21 December 2022 in Journal of Diagnostic Medical Sonography
Verified
Journal Article
Open access
HKHazal Kutlucan
Hazal Kutlucan
GIGizem Işık
Gizem Işık
MAMünire Funda Cevher Akdulum
Münire Funda Cevher Akdulum
EDErhan Demirdağ
Erhan Demirdağ
ÖEÖzlem Erdem
Özlem Erdem
NBNuray Bozkurt
Nuray Bozkurt
Objective: The principal objective was to compare the diagnostic accuracy of two-dimensional transvaginal ultrasonography (2D TVUS), three-dimensional transvaginal ultrasonography (3D TVUS), and hysteroscopy with histopathology in patients with abnormal uterine bleeding. Materials and Methods: Fifty patients were included and underwent the three imaging methods. The negative predictive value, positive predictive value, sensitivity, and specificity of the methods were calculated. Determination of endometrial pathology and endometrial polyps by measuring the endometrial thickness, volume, and uterine area was examined. Results: The complaint of menorrhagia was reported by 72.0% of participants. Histopathologically, 70.0% of the patients had endometrial polyps and leiomyoma being monitored. An endometrial polyp was detected in 58.0% of the patients by 2D TVUS, 80.0% by 3D TVUS, and 68.0% by hysteroscopy. While 2D TVUS demonstrated 65.71% accuracy in the detection of an endometrial polyp, 3D TVUS had an 80.0% accuracy, and hysteroscopy had a 77.77% accuracy. An endometrial polyp was detected when the uterine area was ≥237 mm2. If the endometrial thickness was over 10.5 mm, it was found to be related to an endometrial polyp. According to the volume measurements by 3D TVUS, the detection of an endometrial polyp was made with 96.4% sensitivity, provided that the pathology volume was ≥0.082 cm3. Conclusion: In this cohort of patients, 3D TVUS achieved a high sensitivity to detect abnormalities and could be considered as an initial diagnostic modality, prior to the surgery, and may rival invasive procedures, such as hysteroscopy.

8 June 2020 in Journal of the Turkish-German Gynecological Association
Verified
Journal Article
Closed access
HKHazal Kutlucan
Hazal Kutlucan
RKRecep Onur Karabacak
Recep Onur Karabacak
DWDirk Wildemeersch
Dirk Wildemeersch
Family planning is a system for attaining the desired number of children and enabling a desired spacing between pregnancies. Family planning can be achieved through both the use of contraceptive methods and the treatment of infertility. A woman's ability to limit her pregnancy has a significant effect on her health.While family planning reduces the rate of unintented pregnancies, it also reduces the number of unsafe abortions. Contraception is an important component of family planning and reproductive health. Among various contraceptive methods, intrauterine devices (IUDs) are very popular because of some of the features of IUDs including being affordable, simplicity of insertion, long duration of action and reversibility. Modern, frameless, copper IUDs contain more copper and their copper content is contained in the solid tubular sleeves rather than in the wire which increases efficacy and lifespan. Immediate postpartum intrauterine device insertion (IPPI) during cesarean section can be considered in women who desire long acting, reversible contraception. Fertility returns instantly after removal of the device and pregnancy rate is not affected. IPPI is a very attractive method, especially for women who have undergone cesarean and require an interval of contraception before getting pregnant again. However, IPPI needs more clinical attention due to many aspects. The advantages remain including the prevention of unintended short interval pregnancies and, by providing an optimal timeframe for post-cesarean uterine recover, can reduce the incidence of the next cesarean delivery. With the publication of international IPPI studies, it will take a place in the range of globally available contraceptive methods, which in this author's opinion, it deserves.