Maulana Yusup Rosadi

Dr. Maulana Yusup Rosadi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
YWYanxia Wu
Yanxia Wu
HDHaixia Du
Haixia Du
FLFusheng Li
Fusheng Li
HSHaoning Su
Haoning Su
Sartaj Ahmad BhatSartaj Ahmad Bhat
Sartaj Ahmad Bhat
HWHuifang Wu
Huifang Wu
Drinking water treatment sludge (DWTS) is a waste by-product from water treatment plants where aluminum and iron salts are the most commonly used coagulants. DWTS was reused to investigate the effects of DWTS on the digestion liquid quality and microorganism activity of excess activated sludge (EAS). DWTS with four suspended solid (SS) concentrations (0%, 2%, 5% and 10%) was added to EAS which was sampled during aerobic and anaerobic digestion processes, then batch tests were carried out which followed the coagulation-flocculation process. It was found that DWTS can improve total dissolved nitrogen (TDN) and dissolved phosphorus (DP) removal efficiencies for anaerobic EAS. The highest removal efficiency of TDN (29.97%) as well as DP (55.38%) was observed when DWTS dosage was SS = 10%. The release of dissolved organic matter (DOM) by DWTS could increase dissolved organic carbon (DOC) concentration and lead to the accumulation of non-biodegradable humic acid-like substance in aerobic and anaerobic digestion liquid. The dehydrogenase activity (DHA) values of anaerobic EAS were higher than aerobic EAS. DWTS could reduce DHA for both EAS. These results indicate that potential risk of release of DOM should be considered when reusing DWTS in future research.


6 December 2021 in Water
Verified
Journal Article
Open access
PDF file
HHHudori Hudori
Hudori Hudori
MRMaulana Yusup Rosadi
Maulana Yusup Rosadi
TYToshiro Yamada
Toshiro Yamada
Sartaj Ahmad BhatSartaj Ahmad Bhat
Sartaj Ahmad Bhat
FLFusheng Li
Fusheng Li
The recycling process is applied in many water treatment plants (WTPs), although this process can lead to adverse effects. The effect of the recycling process on the characteristics of dissolved organic matter was evaluated based on a fluorescence excitation-emission matrix using the peak-picking technique and self-organizing map (SOM). In this study, an evaluation of two WTPs, one with and one without a recycling system, was carried out. Both WTPs show moderate efficiency during the coagulation–flocculation process in removing DOC, fulvic acid-like, humic acid-like, and tryptophan-like substances. The recycling process causes increased values of fulvic acid-like, humic acid-like, and tryptophan-like substances and specific ultraviolet absorbance (SUVA) after the filtration process of about 31.0%, 35.7%, 22.2%, and 6%, respectively. Meanwhile, the WTP without recycling showed a reduction in the level of fulvic acid-like, humic acid-like, and tryptophan-like substances and SUVA by 23.3%, 52.9%, 27.8%, and 21.1%, respectively. Moreover, SOM analysis based on the peak-picking technique can determine differences in sample clusters due to the recycling process.


20 November 2022 in Water
Verified
Journal Article
Open access
PDF file
RDReni Desmiarti
Reni Desmiarti
MRMaulana Yusup Rosadi
Maulana Yusup Rosadi
AHAriadi Hazmi
Ariadi Hazmi
MRMuhammad Miftahur Rahman
Muhammad Miftahur Rahman
NNNofri Naldi
Nofri Naldi
JFJoni Aldilla Fajri
Joni Aldilla Fajri
In this study, the performance of dielectric barrier discharge (DBD) with the aerated condition at discharge voltages of 15, 20, and 25 kV on the production of biogas; CH4, H2, CO, and CO2 and the removal of COD and BOD from POME were investigated. The experimental results showed that the aerated condition with a rate of 2.5 L/min at a high voltage (25 kV) produced CH4, CO, and CO2 that was 9.4, 21.5, and 19.6 times higher than the non-aerated one, respectively. The maximum cumulative volume of CH4, H2, CO, and CO2 was 95.4 ± 8.92, 0.94 ± 0.71, 3.06 ± 0.73, and 2.45 ± 0.35 mL/mg COD, respectively, under the aerated condition at 25 kV and the experimental data fit well with the polynomial regression (R2 > 95) for the initial biogas production. The decrease in COD and BOD was greatly affected by the high discharge voltage under the aerated condition, resulting in a high removal rate. These findings suggest that good performance was observed when the DBD was integrated with the aerated condition under the optimum discharge voltage. The study can give information on the optimum condition in a laboratory scale to produce CH4, H2, CO, and CO2, as well as the reduction of organic pollutants from POME.

5 January 2022 in Water
Verified
Journal Article
Open access
PDF file
AHAriadi Hazmi
Ariadi Hazmi
MRMaulana Yusup Rosadi
Maulana Yusup Rosadi
RDReni Desmiarti
Reni Desmiarti
FLFusheng Li
Fusheng Li
Rainwater is a potential source of drinking water, but has various components of dissolved organic matter (DOM). DOM is a reservoir of potential hazards in drinking water. Therefore, a new method is required to purify rainwater as a drinking water source in terms of DOM aspects. A radio-frequency (RF) treatment system is introduced here to purify source water with a small possibility of contamination. RF is generated by applying a frequency of 1.5 MHz through a glass reactor with a diameter of 2 mm which is wrapped by a 2 mm copper wire. The results demonstrate that UV260 value and dissolved organic carbon (DOC) are reduced during RF treatment. DOC was reduced by a lower amount compared to UV260, suggesting the partial transformation of bio-refractory DOM. A fluorescence excitation-emission matrix showed that humic-like substances in rainwater were reduced faster than protein-like ones, indicating that humic-like substances are susceptible to reduction by RF treatment. The results offer information on the use of RF treatment in a rainwater purification process for the production of drinking water.