Philippine garlic (Allium sativum L.) is arguably known to pack flavor and aroma in smaller bulbs compared to imported varieties saturating the local market. In this study, ethanolic extracts of Philippine garlic cultivars were profiled using ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF). gamma -Glu dipeptides, oligosaccharides and lipids were determined in Philippine garlic cultivars through bioinformatics analysis in GNPS Molecular Networking Platform and fragmentation analysis. Multivariate statistical analysis using XCMS Online showed the abundance of gamma -Glu allyl cysteine in Batanes-sourced garlic while gamma -Glu propenyl cysteine, gamma -Glu methyl cysteine, and alliin are enriched in the Ilocos cultivar. Principal component analysis showed that the gamma -Glu dipeptides found in local garlic influenced their distinct separation across PC1 from imported varieties. This presence of high levels of gamma -Glu dipeptides and probiotic oligosaccharides may potentially contribute to the superior flavor and nutritional benefits of Philippine garlic.
Underutilized biowaste materials are investigated for their potential as sustainable textile colorants through an approach based on mass spectrometry, bioinformatics, and chemometrics. In this study, colorful decoctions were prepared from the outer bark of Eucalyptus deglupta and fruit peels of Syzygium samarangense, Syzygium malaccense, Diospyros discolor, and Dillenia philippinensis. Textile dyeing was performed along with liquid chromatography–mass spectrometry (LC–MS)-based untargeted metabolomics to determine the small molecules responsible for the observed colors. Global Natural Products Social Molecular Networking (GNPS) guided the annotation of black-producing proanthocyanidins in D. philippinensis and E. deglupta through complexation with FeSO4 mordant. Flavonoids from the yellow-colored D. philippinensis extracts were found to be similar to those in Terminalia catappa, a known traditional dye source. A higher intensity of epicatechin in E. deglupta produced a red-brown color in the presence of Cu2+. Furthermore, Syzygium fruit peels have poor wash-fastness in cotton fibers, but bioactive chalcone unique to S. samarangense samples may be a potential nutritional food colorant. Unsupervised PCA and supervised OPLS-DA chemometrics distinguished chemical features that affect dyeing properties beyond the observed color. These findings, along with growing data on natural dyes, could guide future research on sustainable colorants.
Philippine garlic ( Allium sativum L. ) is arguably known to pack flavor and aroma in smaller bulbs compared to imported varieties saturating the local market. In this study, ethanolic extracts of Philippine garlic cultivars were profiled using ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF). γ-Glu dipeptides, oligosaccharides and lipids were determined in Philippine garlic cultivars through bioinformatics analysis in GNPS Molecular Networking Platform and fragmentation analysis. Multivariate statistical analysis using XCMS Online showed the abundance of γ-Glu allyl cysteine in Batanes-sourced garlic while γ-Glu propenyl cysteine, γ-Glu methyl cysteine, and alliin are enriched in the Ilocos cultivar. Principal component analysis showed that the γ-Glu dipeptides found in local garlic influenced their distinct separation across PC1 from imported varieties. This presence of high levels of γ-Glu dipeptides and probiotic oligosaccharides may potentially contribute to the superior flavor and nutritional benefits of Philippine garlic.
21 April 2026 in Analytical and Bioanalytical Chemistry
Lipidomics provides detailed insight into lipid metabolism and cellular function, but conventional workflows typically rely on bulk samples that mask cellular heterogeneity. Advances in analytical chemistry are enabling lipid analysis from extremely limited material, driving the development of miniaturized chromatography-mass spectrometry (LC-MS) workflows for low-input and single-cell studies. This review summarizes recent progress in miniaturized chromatography-based lipidomics. Reducing chromatographic scale improves ionization efficiency, sensitivity, and separation performance while minimizing sample consumption. We discuss key enabling technologies, such as low-flow electrospray interfaces and the integration of ion mobility (IM) spectrometry as an orthogonal separation dimension for lipid identification. Methodological considerations for low-input lipidomics are also addressed, particularly sample preparation and quantitative challenges at picogram-scale analyte levels. Finally, we highlight future directions in automation, microfluidics, and multidimensional separations. Together, these developments position miniaturized chromatography as a critical platform for advancing single-cell lipidomics and high-resolution studies of lipid metabolism.
Lipidomics provides critical insights into disease mechanisms, biomarker discovery, and precision medicine, but conventional LC-MS workflows often require large sample volumes, limiting their application in minimally invasive studies. Here, we establish a nanoflow liquid chromatography (nanoLC) platform coupled with trapped ion mobility spectrometry and time-of-flight mass spectrometry (TIMS-TOF) for comprehensive lipid profiling from as little as 1 μL of plasma. Two commonly employed single-phase extraction protocols (MeOH:MTBE and IPA:H₂O) were scaled to microsample volumes using NIST® SRM® 1950 plasma, and the influence of mobile phase buffer concentration (10, 5, and 2 mM NH₄HCO₂) on lipid coverage and chromatographic performance was systematically evaluated. Multivariate analysis revealed solvent- and buffer-dependent shifts in lipid distributions, while manual annotation and verification based on ion mobility ensured precise lipid identification, even from small volumes. The optimized nanoLC-TIMS-TOF workflow achieved broad lipid class coverage, enhanced detection of low-abundance species, and improved separation of structurally similar lipids using only 1 μL of starting material. Compared to high-flow LC-MS approaches, similar lipid coverage was achieved at lower buffer concentrations, though ammonium adduct formation introduced distinct lipid-specific biases. These results demonstrate the robustness and scalability of nanoLC-TIMS-MS lipidomics for sample-limited applications.