Background and Aim: Pan-enteric capsule endoscopy [PCE] is a highly sensitive but time-consuming tool for detecting pathology. Artificial intelligence [AI] algorithms might offer a possibility to assist in the review and reduce the analysis time of PCE. This study examines the agreement between PCE assessments aided by AI technology and standard evaluations, in patients suspected of Crohn’s disease [CD]. Method: PCEs from a prospective, blinded, multicentre study, including patients suspected of CD, were processed by the deep learning solution AXARO® [Augmented Endoscopy, Paris, France]. Based on the image output, two observers classified the patient’s PCE as normal or suggestive of CD, ulcerative colitis, or cancer. The primary outcome was per-patient sensitivities and specificities for detecting CD and inflammatory bowel disease [IBD]. Complete reading of PCE served as the reference standard. Results: A total of 131 patients’ PCEs were analysed, with a median recording time of 303 min. The AXARO® framework reduced output to a median of 470 images [2.1%] per patient, and the pooled median review time was 3.2 min per patient. For detecting CD, the observers had a sensitivity of 96% and 92% and a specificity of 93% and 90%, respectively. For the detection of IBD, both observers had a sensitivity of 97% and had a specificity of 91% and 90%, respectively. The negative predictive value was 95% for CD and 97% for IBD. Conclusions: Using the AXARO® framework reduced the initial review time substantially while maintaining high diagnostic accuracy—suggesting its use as a rapid tool to rule out IBD in PCEs of patients suspected of Crohn’s disease.
Background Cleanliness scores in small-bowel capsule endoscopy (SBCE) have poor reproducibility. The aim of this study was to evaluate a neural network-based algorithm for automated assessment of small-bowel cleanliness during capsule endoscopy. Methods 600 normal third-generation SBCE still frames were categorized as “adequate” or “inadequate” in terms of cleanliness by three expert readers, according to a 10-point scale, and served as a training database. Then, 156 third-generation SBCE recordings were categorized in a consensual manner as “adequate” or “inadequate” in terms of cleanliness; this testing database was split into two independent 78-video subsets for the tuning and evaluation of the algorithm, respectively. Results Using a threshold of 79 % “adequate” still frames per video to achieve the best performance, the algorithm yielded a sensitivity of 90.3 %, specificity of 83.3 %, and accuracy of 89.7 %. The reproducibility was perfect. The mean calculation time per video was 3 (standard deviation 1) minutes. Conclusion This neural network-based algorithm allowing automatic assessment of small-bowel cleanliness during capsule endoscopy was highly sensitive and paves the way for automated, standardized SBCE reports.
Artificial intelligence (AI) has shown promising results in digestive endoscopy, especially in capsule endoscopy (CE). However, some physicians still have some difficulties and fear the advent of this technology. We aimed to evaluate the perceptions and current sentiments toward the use of AI in CE. An online survey questionnaire was sent to an audience of gastroenterologists. In addition, several European national leaders of the International CApsule endoscopy REsearch (I CARE) Group were asked to disseminate an online survey among their national communities of CE readers (CER). The survey included 32 questions regarding general information, perceptions of AI, and its use in daily life, medicine, endoscopy, and CE. Among 380 European gastroenterologists who answered this survey, 333 (88%) were CERs. The mean average time length of experience in CE reading was 9.9 years (0.5–22). A majority of CERs agreed that AI would positively impact CE, shorten CE reading time, and help standardize reporting in CE and characterize lesions seen in CE. Nevertheless, in the foreseeable future, a majority of CERs disagreed with the complete replacement all CE reading by AI. Most CERs believed in the high potential of AI for becoming a valuable tool for automated diagnosis and for shortening the reading time. Currently, the perception is that AI will not replace CE reading.
(1) Background: Villous atrophy is an indication for small bowel capsule endoscopy (SBCE). However, SBCE findings are not described uniformly and atrophic features are sometimes not recognized; (2) Methods: The Delphi technique was employed to reach agreement among a panel of SBCE experts. The nomenclature and definitions of SBCE lesions suggesting the presence of atrophy were decided in a core group of 10 experts. Four images of each lesion were chosen from a large SBCE database and agreement on the correspondence between the picture and the definition was evaluated using the Delphi method in a broadened group of 36 experts. All images corresponded to histologically proven mucosal atrophy; (3) Results: Four types of atrophic lesions were identified: mosaicism, scalloping, folds reduction, and granular mucosa. The core group succeeded in reaching agreement on the nomenclature and the descriptions of these items. Consensus in matching the agreed definitions for the proposed set of images was met for mosaicism (88.9% in the first round), scalloping (97.2% in the first round), and folds reduction (94.4% in the first round), but granular mucosa failed to achieve consensus (75.0% in the third round); (4) Conclusions: Consensus among SBCE experts on atrophic lesions was met for the first time. Mosaicism, scalloping, and folds reduction are the most reliable signs, while the description of granular mucosa remains uncertain.
31 October 2022 in Therapeutic Advances in Gastroenterology
Background: Artificial intelligence (AI) is rapidly infiltrating multiple areas in medicine, with gastrointestinal endoscopy paving the way in both research and clinical applications. Multiple challenges associated with the incorporation of AI in endoscopy are being addressed in recent consensus documents. Objectives: In the current paper, we aimed to map future challenges and areas of research for the incorporation of AI in capsule endoscopy (CE) practice. Design: Modified three-round Delphi consensus online survey. Methods: The study design was based on a modified three-round Delphi consensus online survey distributed to a group of CE and AI experts. Round one aimed to map out key research statements and challenges for the implementation of AI in CE. All queries addressing the same questions were merged into a single issue. The second round aimed to rank all generated questions during round one and to identify the top-ranked statements with the highest total score. Finally, the third round aimed to redistribute and rescore the top-ranked statements. Results: Twenty-one (16 gastroenterologists and 5 data scientists) experts participated in the survey. In the first round, 48 statements divided into seven themes were generated. After scoring all statements and rescoring the top 12, the question of AI use for identification and grading of small bowel pathologies was scored the highest (mean score 9.15), correlation of AI and human expert reading-second (9.05), and real-life feasibility-third (9.0). Conclusion: In summary, our current study points out a roadmap for future challenges and research areas on our way to fully incorporating AI in CE reading.
Background: Bubbles often mask the mucosa during capsule endoscopy (CE). Clinical scores assessing the cleanliness and the amount of bubbles in the small bowel (SB) are poorly reproducible unlike machine learning (ML) solutions. We aimed to measure the amount of bubbles with ML algorithms in SB CE recordings, and compare two polyethylene glycol (PEG)-based preparations, with and without simethicone, in patients with obscure gastro-intestinal bleeding (OGIB). Patients & Methods: All consecutive outpatients with OGIB from a tertiary care center received a PEG-based preparation, without or with simethicone, in two different periods. The primary outcome was a difference in the proportions (%) of frames with abundant bubbles (>10%) along the full-length video sequences between the two periods. SB CE recordings were analyzed by a validated computed algorithm based on a grey-level of co-occurrence matrix (GLCM), to assess the abundance of bubbles in each frame. Results: In total, 105 third generation SB CE recordings were analyzed (48 without simethicone and 57 with simethicone-added preparations). A significant association was shown between the use of a simethicone-added preparation and a lower abundance of bubbles along the SB (p = 0.04). A significantly lower proportion of “abundant in bubbles” frames was observed in the fourth quartile (30.5% vs. 20.6%, p = 0.02). There was no significant impact of the use of simethicone in terms of diagnostic yield, SB transit time and completion rate. Conclusion: An accurate and reproducible computed algorithm demonstrated significant decrease in the abundance of bubbles along SB CE recordings, with a marked effect in the last quartile, in patients for whom simethicone had been added in PEG-based preparations, compared to those without simethicone.