A series of tubes: The continuous manufacture of a finished drug product starting from chemical intermediates is reported. The continuous pilot-scale plant used a novel route that incorporated many advantages of continuous-flow processes to produce active pharmaceutical ingredients and the drug product in one integrated system.
6 February 2014 in Organic Process Research & Development
The development and operation of the synthesis and workup steps of a fully integrated, continuous manufacturing plant for synthesizing aliskiren, a small molecule pharmaceutical, are presented. The plant started with advanced intermediates, two synthetic steps away from the final active pharmaceutical ingredient, and ended with finished tablets. The entire process was run on several occasions, with the data presented herein corresponding to a 240 h run at a nominal throughput of 41 g h–1 of aliskiren. The first reaction was performed solvent-free in a molten condition at a high temperature, achieving high yields (90%) and avoiding solid handling and a long residence time (due to higher concentrations compared to dilute conditions when run at lower temperatures in a solvent). The resulting stream was worked-up inline using liquid–liquid extraction with membrane-based separators that were scaled-up from microfluidic designs. The second reaction involved a Boc deprotection, using aqueous HCl that was rapidly quenched with aqueous NaOH using an inline pH measurement to control NaOH addition. The reaction maintained high yields (90–95%) under closed-loop control despite process disturbances.
15 November 2012 in Industrial & Engineering Chemistry Research
Continuous manufacturing offers potential opportunities for the improved manufacturing of pharmaceutical products. A key challenge is the development of an appropriate control strategy. The experimental application of an automated control strategy is presented for an end-to-end continuous pharmaceutical pilot plant. The process starts from an advanced intermediate compound and finishes with the tablet formation steps. The focus of the experimental results is on the design and performance of the control loops needed to produce a slurry of an active pharmaceutical ingredient and a solvent with specified material properties. The results demonstrate that automated control can successfully keep critical material attributes close to the desired set points for a sustained period of operation. This work aims to contribute to the development of future continuous pharmaceutical processes by providing a realistic case study of automated control of an integrated, continuous, pharmaceutical pilot plant.
This is an Open Access Article. It is published by Elsevier under the Creative Commons Attribution 4.0 Unported Licence (CC BY). Full details of this licence are available at: http://creativecommons.org/licenses/by/4.0/A series of poly[methacrylamide-co-(ethylene glycol dimethacrylate)] (poly(MAAM-co-EGDMA)) porous polymeric particles with high CO2-philicity, referred to as HCP-MAAM, were synthesised for CO2 capture. The polymers with a MAAM-to-EGDMA molar ratio from 0.3 to 0.9 were inherently nitrogen-enriched and exhibited a high affinity towards selective CO2 capture at low pressures. A techno-economic model based on a 580 MWel supercritical coal-fired power plant scenario was developed to evaluate the performance of the synthesised adsorbents. The presence and density of NH2 moieties within the polymer network were determined using Fourier transform infrared (FTIR) spectroscopy and x-ray photoelectron spectroscopy (XPS). The thermogravimetric analysis (TGA) showed that the polymers were thermally stable up to 242-259°C. The maximum CO2 adsorption capacity at 273 K was 1.56 mmol/g and the isosteric heat of adsorption was 28−35 kJ/mol. An increase in the density of amide groups within the polymer network resulted in a higher affinity towards CO2 at low pressure. At a CO2:N2 ratio of 15:85, CO2/N2 selectivity at 273 K was 52 at 1 bar and reached 104 at ultra-low CO2 partial pressure. The techno-economic analysis revealed that retrofitting a HCP-MAAM-based CO2 capture system led to a net energy penalty of 7.7–8.0%HHV points, which was noticeably lower than that reported for MEA or chilled ammonia scrubbing capture systems. The specific heat requirement was superior to the majority of conventional solvents such as MDEA-PZ and K2CO3. Importantly, the economic performance of the HCP-MAAM retrofit scenario was found to be competitive to chemical solvent scrubbing scenarios