The electro-hydrostatic actuator (EHA) has a high energy density and a compact structure so it is widely used in all/more electric aircraft. To gain energy-saving capability, the hydraulic lock can be applied in the EHA system, which can overcome the change of load after the position control is complete, reducing the motor’s need to work continuously. Due to the use of a hydraulic lock in the EHA system, there is a more significant position output delay compared with the EHA system. The delay would lead to a dynamic response error. Therefore, an electro-hydrostatic actuator with a bidirectional hydraulic lock (BHL-EHA) model is established that can reflect the position output delay and it can be used to analyze its influence factors. According to the analysis, the factors affecting the delay are pump speed, external load, hydraulic lock cracking pressure, friction load, pump displacement, fluid volume of the system, and effective bulk modulus; thus, an equation that can be used to calculate the delay is proposed. At the same time, the experimental system of the BHL-EHA system is established, and the parameters of the experimental facility are completely consistent with the simulation model. Finally, a delay compensation control method is proposed, and the control time parameter is calculated based on the equation proposed above. The results of the simulation and the experiment show that the method can compensate for the delay caused by the hydraulic lock. Combined with a feedforward control, the method can dismiss the dynamic response error of 0.6 Hz sinusoidal tracking characteristics.
The main data source for the verification of surge detection methods still rely on test rigs of the compressor or the whole engine, which makes the development of models of the whole engine surge process an urgent need to replace the high-cost and high-risk surge test. In this paper, a novel real-time surge model based on the surge mechanism is proposed. Firstly, the turboshaft engine component level model (CLM) and the classic surge dynamic model, Moore-Greitzer (MG) model is established. Then the stability of the MG model is analyzed and the compressor characteristics in the classical MG model are extended to establish the extended MG model. Finally, this paper considers the coupling relationship of the compressor’s rotor speed, mass flow and pressure between CLM and the extended MG model to establish the real-time model of the turboshaft engine with surge process. The simulation results show that this model can realize the whole surge process of the turboshaft engine under multiple operating states. The change characteristics of the rotor speed, compressor outlet pressure, mass flow, exhaust gas temperature and other parameters are consistent with the test data, which means that the model proposed can be further applied to the research of surge detection and anti-surge control.
This paper presents a fault-tolerant control scheme for the sensor fault in the acceleration process of the variable cycle engine. Firstly, an adaptive equilibrium manifold model with multiple inputs and multiple outputs is established. Combined with the Kalman filter bank, sensor fault diagnosis is carried out to realize the diagnosis and signal reconstruction of the engine in the case of a single sensor and double sensor faults. On this basis, isolation and group isolation are used to diagnose sensor faults and reconstruct signal in speed closed-loop control. Then, the control plan of the acceleration process is optimized based on the target shooting method, aiming to simulate the variation of various variables in the engine acceleration process more accurately, so as to verify the feasibility of the sensor fault-tolerant control scheme. Finally, a hardware-in-loop simulation platform is built based on the idea of distributed control, and the fault-tolerant control scheme of the sensor proposed previously is verified based on this platform. The results show that the proposed scheme can accurately diagnose the sensor faults and reconstruct the signal within 0.2 s, and the actual speed can rise from 67.87% to 99.9% in 4 s, ensuring the safe and rapid completion of the acceleration process.
Today, the more electric aircraft (MEA) concept is gaining tremendous popularity. As a key component of the MEA, a more electric auxiliary power unit (MEAPU) integrated model with high accuracy and real-time performance is essential when conducting cooperative control and hardware-in-the-loop (HIL) test research. This paper proposes a novel MEAPU integrated model consisting of a MEAPU component-level-model (CLM) and a starter-generator (SG) model. Firstly, a MEAPU CLM was built and a continuous scaling method for the component characteristic map in the CLM is proposed to improve the model’s accuracy. Then, a double winding induction starter-generator (DWISG) model based on the electromagnetic theory, which is quite time consuming, was simplified using the pulse width modulation (PWM) rectifier linearization method. Finally, considering the coupling relationship between the MEAPU CLM and DWISG, an accurate real-time MEAPU integrated model was built and its simulation results were analyzed. Compared with the test results, the error of the proposed model was less than 0.5%; meanwhile its single-step simulation time was less than 20 ms, which can meet the demands of cooperative control and HIL test research. Furthermore, the continuous scaling method and PWM rectifier linearization method were found to be effective for modeling other MEAPUs and more electric engines (MEE).