Mohammad Reza Hairi Yazdi

Prof. Mohammad Reza Hairi Yazdi

Professor, School of Mechanical Engineering, University of Tehran
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2016 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
FTFarid Tajaddodianfar
Farid Tajaddodianfar
Mohammad Reza Hairi YazdiMohammad Reza Hairi Yazdi
Mohammad Reza Hairi Yazdi
HPHossein Nejat Pishkenari
Hossein Nejat Pishkenari

1 November 2020 in International Journal of Solids and Structures
Verified
Journal Article
Closed access
SSSoroush Sepehri
Soroush Sepehri
Hamid JafariHamid Jafari
Hamid Jafari
MMMahmoud Mosavi Mashhadi
Mahmoud Mosavi Mashhadi
Mohammad Reza Hairi YazdiMohammad Reza Hairi Yazdi
Mohammad Reza Hairi Yazdi
MFMir Masoud Seyyed Fakhrabadi
Mir Masoud Seyyed Fakhrabadi

1 June 2019 in Energy
Verified
Journal Article
Closed access
MEM.J. Esfandyari
M.J. Esfandyari
VEVahid Esfahanian
Vahid Esfahanian
Mohammad Reza Hairi YazdiMohammad Reza Hairi Yazdi
Mohammad Reza Hairi Yazdi
HNH. Nehzati
H. Nehzati
OSO. Shekoofa
O. Shekoofa

1 August 2018 in Applied Mathematical Modelling
Verified
Journal Article
Closed access
AVAmin Vahidi-Moghaddam
Amin Vahidi-Moghaddam
ARArman Rajaei
Arman Rajaei
RVRamin Vatankhah
Ramin Vatankhah
Mohammad Reza Hairi YazdiMohammad Reza Hairi Yazdi
Mohammad Reza Hairi Yazdi


11 May 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
MHMohammad Reza Haghjoo
Mohammad Reza Haghjoo
HLHosu Lee
Hosu Lee
MAMuhammad Raheel Afzal
Muhammad Raheel Afzal
AEAmre Eizad
Amre Eizad
JYJungwon Yoon
Jungwon Yoon
In this paper, a novel lower extremity gait rehabilitation device with a single actuator is presented. The proposed device, Mech-Walker, utilizes the single Degree of Freedom (DOF) 8-bar Jansen's mechanism. The mechanism is synthesized to generate the ankle trajectory of human gait, relative to the hip, in terms of both position and time. Two mechanisms, one for each leg, are applied reciprocally and are mechanically synchronized to guarantee symmetric gait. A custom designed seat-type weight support system mounted over a commercially available treadmill is also introduced. It not only supports the user and the mechanisms but also links the mechanism's base to the subject's hip. This vertically movable-base allows ground contact proprioception for the user which is crucial in gait training. As this is a non-anthropomorphic design interacting with the leg only at hip and ankle via seat and footrest respectively, it does not need to be aligned with the subject's joints, which facilitates the donning and doffing of the device. Adjustability of mechanism to different users has also been considered to provide an effective training tool. A prototype is manufactured, and pilot study with a healthy subject is conducted. Due to ease of control, cost-effectiveness and high intrinsic safety, the proposed system potentially offers a novel tool for gait training.