Kristen Rak

Prof. Kristen Rak

Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2023 in npj Parkinson's Disease
Verified
Journal Article
Open access
PDF file
AKA. Kuzkina
A. Kuzkina
JRJ. Rößle
J. Rößle
ASA. Seger
A. Seger
CPC. Panzer
C. Panzer
AKA. Kohl
A. Kohl
KDK. Doppler
K. Doppler
Seed amplification assays (SAA) are becoming commonly used in synucleinopathies to detect α-synuclein aggregates. Studies in Parkinson’s disease (PD) and isolated REM-sleep behavior disorder (iRBD) have shown a considerably lower sensitivity in the olfactory epithelium than in CSF or skin. To get an insight into α-synuclein (α-syn) distribution within the nervous system and reasons for low sensitivity, we compared SAA assessment of nasal brushings and skin biopsies in PD (n = 27) and iRBD patients (n = 18) and unaffected controls (n = 30). α-syn misfolding was overall found less commonly in the olfactory epithelium than in the skin, which could be partially explained by the nasal brushing matrix exerting an inhibitory effect on aggregation. Importantly, the α-syn distribution was not uniform: there was a higher deposition of misfolded α-syn across all sampled tissues in the iRBD cohort compared to PD (supporting the notion of RBD as a marker of a more malignant subtype of synucleinopathy) and in a subgroup of PD patients, misfolded α-syn was detectable only in the olfactory epithelium, suggestive of the recently proposed brain-first PD subtype. Assaying α-syn of diverse origins, such as olfactory (part of the central nervous system) and skin (peripheral nervous system), could increase diagnostic accuracy and allow better stratification of patients.

1 September 2017 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Closed access
JVJohannes Völker
Johannes Völker
CVChristine Völker
Christine Völker
PSPhilipp Schendzielorz
Philipp Schendzielorz
SSSebastian P. Schraven
Sebastian P. Schraven
ARAndreas Radeloff
Andreas Radeloff
KRKristen Rak
Kristen Rak

Verified
Journal Article
Open access
PDF file
AKAnja Kurz
Anja Kurz
DHDavid P. Herrmann
David P. Herrmann
RHRudolf Hagen
Rudolf Hagen
KRKristen Rak
Kristen Rak
Fitting cochlear implant (CI) users can be challenging. Anatomy-based fitting (ABF) maps may have the potential to lead to better objective and subjective outcomes than conventional clinically based fitting (CBF) methods. ABF maps were created via information derived from exact electrode contact positions, which were determined via post-operative high-resolution flat panel volume computer tomography and clinical fitting software. The outcome measures were speech understanding in quiet and noise and self-perceived sound quality with the CBF map and with the ABF map. Participants were 10 experienced bilateral CI users. The ABF map provided better speech understanding in quiet and noisy environments compared to the CBF map. Additionally, two approaches of reducing the frequency-to-place mismatch revealed that participants are more likely to accept the ABF map if their electrode array is inserted deep enough to stimulate the apical region of their cochlea. This suggests an Angular Insertion Depth of the most apical contact of around 720°–620°. Participants had better speech understanding in quiet and noise with the ABF map. The maps’ self-perceived sound quality was similar. ABF mapping may be an effective tool for compensating the frequency-to-place mismatch in experienced bilateral CI users.

26 January 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
JTJohannes Taeger
Johannes Taeger
SBStefanie Bischoff
Stefanie Bischoff
RHRudolf Hagen
Rudolf Hagen
KRKristen Rak
Kristen Rak
Background: For the classification of facial paresis, various systems of description and evaluation in the form of clinician-graded or software-based scoring systems are available. They serve the purpose of scientific and clinical assessment of the spontaneous course of the disease or monitoring therapeutic interventions. Nevertheless, none have been able to achieve universal acceptance in everyday clinical practice. Hence, a quick and precise tool for assessing the functional status of the facial nerve would be desirable. In this context, the possibilities that the TrueDepth camera of recent iPhone models offer have sparked our interest. Objective: This paper describes the utilization of the iPhone’s TrueDepth camera via a specially developed app prototype for quick, objective, and reproducible quantification of facial asymmetries. Methods: After conceptual and user interface design, a native app prototype for iOS was programmed that accesses and processes the data of the TrueDepth camera. Using a special algorithm, a new index for the grading of unilateral facial paresis ranging from 0% to 100% was developed. The algorithm was adapted to the well-established Stennert index by weighting the individual facial regions based on functional and cosmetic aspects. Test measurements with healthy subjects using the app were performed in order to prove the reliability of the system. Results: After the development process, the app prototype had no runtime or buildtime errors and also worked under suboptimal conditions such as different measurement angles, so it met our criteria for a safe and reliable app. The newly defined index expresses the result of the measurements as a generally understandable percentage value for each half of the face. The measurements that correctly rated the facial expressions of healthy individuals as symmetrical in all cases were reproducible and showed no statistically significant intertest variability. Conclusions: Based on the experience with the app prototype assessing healthy subjects, the use of the TrueDepth camera should have considerable potential for app-based grading of facial movement disorders. The app and its algorithm, which is based on theoretical considerations, should be evaluated in a prospective clinical study and correlated with common facial scores.

14 December 2020 in Otology & Neurotology
Verified
Journal Article
Closed access
PSPhilipp Schendzielorz
Philipp Schendzielorz
LILukas Ilgen
Lukas Ilgen
TMTassilo Mueller-Graff
Tassilo Mueller-Graff
LNLaurent Noyalet
Laurent Noyalet
JVJohannes Völker
Johannes Völker
KRKristen Rak
Kristen Rak
Hypothesis: Flat-panel volume computed tomography (fpVCT) and secondary reconstruction allow for more accurate measurements of two-turn length (2TL), cochlear duct length (CDL), and angular length (AL). Background: Cochlear geometry is a controversially debated topic. In the meantime, there are many different studies partly reporting highly divergent values. Our aim is to discuss the differences and to propose a radiological possibility to improve cochlear measurements using 3D-curved multiplanar reconstruction and fpVCT. Methods: Performing different image modalities and settings, we tried to find a clinically usable option that allows for a high degree of accuracy. Therefore, we tested them against reference values of high-definition micro-computed tomography. Results: Comparison of 99 μm slice thickness secondary reconstruction of fpVCT and reference showed no significant differences for 2TL and CDL (p ≥ 0.05). Accordingly, ICC (intraclass correlation) values were excellent (ICC ≥ 0.75; lower limit of confidence interval [CI] ≥ 0.75; Cronbach's alpha [α] ≥ 0.9). Evaluating AL, there was a significant difference (difference: −17.27°; p = 0.002). The lower limit of the CI of the ICC was unacceptable (ICC = 0.944; lower limit of CI = 0.248; α = 0.990). Regarding the Bland-Altman plots, there were no clinically unacceptable errors, but a systematic underestimation of AL. Conclusion: Secondary reconstruction is a suitable tool for producing reliable data that allow the accurate measurement of 2TL and CDL. The option of generating these reconstructions from raw data limits the need for higher radiation doses. Nevertheless, there is an underestimation of AL using secondary reconstructions.

1 December 2019 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Closed access
DEDésirée Ehrmann-Müller
Désirée Ehrmann-Müller
MCMario Cebulla
Mario Cebulla
KRKristen Rak
Kristen Rak
MSMatthias Scheich
Matthias Scheich
DBDaniela Back
Daniela Back
WSWafaa Shehata-Dieler
Wafaa Shehata-Dieler