The clearance of mucus through coughing is a complex, multiphase process, which is affected principally by mucus viscosity and airflow velocity; however, it is also critically affected by the thickness of the two layers of mucus—the serous and gel layers—and oscillation level. The present study examines the effects of the latter parameters more closely. To do so, the mucus clearance process is simulated with a transient 3D volume of fluid (VOF) multiphase model in ANSYS Fluent. The model includes mucus’ bilayer properties and a wide range of boundary conditions were tested. The model was analysed in both a straight tube and a realistic trachea. Ultimately, the model was able to both capture air-mucus interface wave evolution and predict the overall behaviour of the clearance process. The results were consistent with experimental clearance data and numerical airflow simulations, which indicates our methodology is appropriate for future studies. Ultimately, the mere presence of the serous layer was found to increase mucus clearance by more than 15 percent. An oscillating flow enhanced clearance by up to 5 percent. Interestingly, interface wave steepness was found to be inversely correlated with mucus thickness, but directly with mucus velocity, which suggests it will be an interesting parameter for further study.
1 July 2021 in Computer Methods and Programs in Biomedicine
Purpose: There are still many challenges for modelling a thrombus migration process in aneurysms. The main novelty of the present research lies in the modelling of aneurysm clot migration process in a realistic cerebral aneurysm, and the analysis of forces suffered by clots inside an aneurysm, through transient FSI simulations. Methods: The blood flow has been modelled using a Womersley velocity profile, and following the Carreau viscosity model. Hyperelastic Ogden model has been used for clot and isotropic linear elastic model for the artery walls. The FSI coupled model was implemented in ANSYS® software. The hemodynamic forces suffered by the clot have been quantified using eight different clot sizes and positions inside a real aneurysm. Results: The obtained results have shown that it is almost impossible for clots adjacent to aneurysm walls, to leave the aneurysm. Nevertheless, in clots positioned in the centre of the aneurysm, there is a real risk of clot migration. The risk of migration of a typical post-coiling intervention clot in an aneurysm, in contact with the wall and occupying a significant percentage of its volume is very low in the case studied, even in the presence of abnormally intense events, associated with sneezes or impacts. Conclusions: The proposed methodology allows evaluating the clot migration risk, vital for evaluating the progress after endovascular interventions, it is a step forward in the personalized medicine, patient follow-up, and helping the medical team deciding the optimal treatment. Graphical
9 August 2024 in International Journal of Heat and Mass Transfer