Dante A. Elias

Dr. Dante A. Elias

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2023 in Robotics
Verified
Journal Article
Open access
PDF file
Victoria E. AbarcaVictoria E. Abarca
Victoria E. Abarca
DEDante A. Elias
Dante A. Elias
This review article presents an in-depth examination of research and development in the fields of rehabilitation, assistive technologies, and humanoid robots. It focuses on parallel robots designed for human body joints with three degrees of freedom, specifically the neck, shoulder, wrist, hip, and ankle. A systematic search was conducted across multiple databases, including Scopus, Web of Science, PubMed, IEEE Xplore, ScienceDirect, the Directory of Open Access Journals, and the ASME Journal. This systematic review offers an updated overview of advancements in the field from 2012 to 2023. After applying exclusion criteria, 93 papers were selected for in-depth review. This cohort included 13 articles focusing on the neck joint, 19 on the shoulder joint, 22 on the wrist joint, 9 on the hip joint, and 30 on the ankle joint. The article discusses the timeline and advancements of parallel robots, covering technology readiness levels (TRLs), design, the number of degrees of freedom, kinematics structure, workspace assessment, functional capabilities, performance evaluation methods, and material selection for the development of parallel robotics. It also examines critical technological challenges and future prospects in rehabilitation, assistance, and humanoid robots.

19 March 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
Diego SeguraDiego Segura
Diego Segura
EREnzo Romero
Enzo Romero
Victoria E. AbarcaVictoria E. Abarca
Victoria E. Abarca
DEDante A. Elias
Dante A. Elias
This review article aims to provide an updated and comprehensive overview of the latest trends in adult upper limb prostheses, specifically targeting various amputation levels such as transradial, transmetacarpal, transcarpal, and transhumeral. A systematic search was conducted across multiple databases, including IEEE Xplore, MDPI, Scopus, Frontiers, and Espacenet, covering from 2018 to 2023. After applying exclusion criteria, 49 scientific articles (33 patents and 16 commercial prostheses) were meticulously selected for review. The article offers an in-depth analysis of several critical aspects of upper limb prostheses. It discusses the evolution and current state of input control mechanisms, the number of degrees of freedom, and the variety of grips available in prostheses, all tailored according to the level of amputation. Additionally, the review delves into the selection of materials used in developing these prostheses and examines the progression of technology readiness levels. A significant focus is also placed on the evolution of prosthesis weight over the years for different amputation levels. Moreover, the review identifies and explores critical technological challenges and prospects in upper limb prostheses. Finally, the article culminates with a conclusion that encapsulates the key findings and insights on the advancements and ongoing developments in this field.

21 November 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
Omar A. Gonzales-HuisaOmar A. Gonzales-Huisa
Omar A. Gonzales-Huisa
GOGonzalo Oshiro
Gonzalo Oshiro
Victoria E. AbarcaVictoria E. Abarca
Victoria E. Abarca
JEJorge G. Chavez Echajaya
Jorge G. Chavez Echajaya
DEDante A. Elias
Dante A. Elias
Despite recent advancements in prosthetic technology, lower-limb amputees often remain limited to passive prostheses, which leads to an asymmetric gait and increased energy expenditure. Developing active prostheses with effective control systems is important to improve mobility for these individuals. This study presents a machine-learning-based approach to classify five distinct locomotion tasks: ground-level walking (GWL), ramp ascent (RPA), ramp descent (RPD), stairs ascent (SSA), and stairs descent (SSD). The dataset comprises fused electromyographic (EMG) and inertial measurement unit (IMU) signals from twenty non-amputated and five transtibial amputated participants. EMG sensors were strategically positioned on the thigh muscles, while IMU sensors were placed on various leg segments. The performance of two classification algorithms, support vector machine (SVM) and long short-term memory (LSTM), were evaluated on segmented data. The results indicate that SVM models outperform LSTM models in accuracy, precision, and F1 score in the individual evaluation of amputee and non-amputee datasets for 80–20 and 50–50 data distributions. In the 80–20 distribution, an accuracy of 95.46% and 95.35% was obtained with SVM for non-amputees and amputees, respectively. An accuracy of 93.33% and 93.30% was obtained for non-amputees and amputees by using LSTM, respectively. LSTM models show more robustness and inter-population generalizability than SVM models when applying domain-adaptation techniques. Furthermore, the average classification latency for SVM and LSTM models was 19.84 ms and 37.07 ms, respectively, within acceptable limits for real-time applications. This study contributes to the field by comprehensively comparing SVM and LSTM classifiers for locomotion tasks, laying the foundation for the future development of real-time control systems for active transtibial prostheses.

20 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
BCBryan Joel Rivera Calagua
Bryan Joel Rivera Calagua
Consuelo Corazón Cano GallardoConsuelo Corazón Cano Gallardo
Consuelo Corazón Cano Gallardo
ILIsrael Luis
Israel Luis
DEDante A. Elias
Dante A. Elias
Wearable technology has been developed in recent years to monitor biomechanical variables in less restricted environments and in a more affordable way than optical motion capture systems. This paper proposes the development of a 3D printed knee wearable goniometer that uses a Hall-effect sensor to measure the knee flexion angle, which works with a mobile app that shows the angle in real-time as well as the activity the user is performing (standing, sitting, or walking). Detection of the activity is done through an algorithm that uses the knee angle and angular speeds as inputs. The measurements of the wearable are compared with a commercial goniometer, and, with the Aktos-t system, a commercial motion capture system based on inertial sensors, at three speeds of gait (4.0 km/h, 4.5 km/h, and 5.0 km/h) in nine participants. Specifically, the four differences between maximum and minimum peaks in the gait cycle, starting with heel-strike, were compared by using the mean absolute error, which was between 2.46 and 12.49 on average. In addition, the algorithm was able to predict the three activities during online testing in one participant and detected on average 94.66% of the gait cycles performed by the participants during offline testing.

22 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ACAlonso A. Cifuentes-Cuadros
Alonso A. Cifuentes-Cuadros
EREnzo Romero
Enzo Romero
SCSebastian Caballa
Sebastian Caballa
DVDaniela Vega-Centeno
Daniela Vega-Centeno
DEDante A. Elias
Dante A. Elias
Globally, 2.5% of upper limb amputations are transhumeral, and both mechanical and electronic prosthetics are being developed for individuals with this condition. Mechanics often require compensatory movements that can lead to awkward gestures. Electronic types are mainly controlled by superficial electromyography (sEMG). However, in proximal amputations, the residual limb is utilized less frequently in daily activities. Muscle shortening increases with time and results in weakened sEMG readings. Therefore, sEMG-controlled models exhibit a low success rate in executing gestures. The LIBRA NeuroLimb prosthesis is introduced to address this problem. It features three active and four passive degrees of freedom (DOF), offers up to 8 h of operation, and employs a hybrid control system that combines sEMG and electroencephalography (EEG) signal classification. The sEMG and EEG classification models achieve up to 99% and 76% accuracy, respectively, enabling precise real-time control. The prosthesis can perform a grip within as little as 0.3 s, exerting up to 21.26 N of pinch force. Training and validation sessions were conducted with two volunteers. Assessed with the “AM-ULA” test, scores of 222 and 144 demonstrated the prosthesis’s potential to improve the user’s ability to perform daily activities. Future work will prioritize enhancing the mechanical strength, increasing active DOF, and refining real-world usability.

23 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ABAntonio Padilha Lanari Bo
Antonio Padilha Lanari Bo
LCLeslie Casas
Leslie Casas
Gonzalo Cucho-PadinGonzalo Cucho-Padin
Gonzalo Cucho-Padin
MHMitsuhiro Hayashibe
Mitsuhiro Hayashibe
DEDante A. Elias
Dante A. Elias
Among end-effector robots for lower limb rehabilitation, systems based on Stewart–Gough platforms enable independent movement of each foot in six degrees of freedom. Nevertheless, control strategies described in recent literature have not been able to fully explore the potential of such a mechatronic system. In this work, we propose two novel approaches for controlling a gait simulator based on Stewart–Gough platforms. The first strategy provides the therapist direct control of each platform using movement data measured by wearable sensors. The following scheme is designed to improve the level of engagement of the patient by enabling a limited degree of control based on trunk inclination. Both strategies are designed to facilitate future studies in tele-rehabilitation settings. Experimental results have illustrated the feasibility of both control interfaces, either in terms of system performance or user subjective evaluation. Technical capacity to deploy in tele-rehabilitation was also verified in this work.