Celine Caillet

Ms. Celine Caillet

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2022 in BMJ Global Health
Verified
Journal Article
Open access
PDF file
GZGuillermo A Zabala
Guillermo A Zabala
KBKhonsavath Bellingham
Khonsavath Bellingham
VVVayouly Vidhamaly
Vayouly Vidhamaly
PBPhonepasith Boupha
Phonepasith Boupha
KBKem Boutsamay
Kem Boutsamay
CCCeline Caillet
Celine Caillet
Objectives Antimicrobial resistance (AMR) is a significant global health threat with substandard and falsified (SF) antibiotics being neglected contributing factors. With their relationships poorly understood, more research is needed in order to determine how interventions to reduce SF antibiotics should be ranked as priorities in national AMR action plans. We assessed the evidence available on the global prevalence of SF antibiotics, examined the quality of the evidence and discussed public health impact. Materials/Methods We searched PubMed, Embase, Google and Google Scholar for publications on antibiotic quality up to 31 December 2020. Publications reporting on the prevalence of SF antibiotics were evaluated for quantitative analysis and assessed using the Medicines Quality Assessment Reporting Guidelines. Results Of the 10 137 screened publications, 648 were relevant to antibiotic quality. One hundred and six (16.4%) surveys, published between 1992 and 2020 and conducted mainly in low-income and middle-income countries (LMICs) (89.9% (480/534) of the data points), qualified for quantitative analysis. The total number of samples tested for quality in prevalence surveys was 13 555, with a median (Q1–Q3) number of samples per survey of 47 (21–135). Of the 13 555 samples, 2357 (17.4%) failed at least one quality test and the median failure frequency (FF) per survey was 19.6% (7.6%–35.0%). Amoxicillin, sulfamethoxazole-trimethoprim and ciprofloxacin were the most surveyed antibiotics, with FF of 16.1% (355/2208), 26.2% (329/1255) and 10.4% (366/3511), respectively. We identified no SF survey data for antibiotics in the WHO ‘Reserve’ group. The mean Medicine Quality Assessment Reporting Guidelines score was 11 (95% CI 10.1 to 12.2) out of 26. Conclusions SF antibiotics are widely spread with higher prevalence in LMICs. The quality of the evidence is poor, and these data are not generalisable that 17.4% of global antibiotic supply is SF. However, the evidence we have suggests that interventions to enhance regulatory, purchasing and financial mechanisms to improve the global antibiotic supply are needed. PROSPERO registration number CRD42019124988.

29 August 2018 in BMJ Global Health
Verified
Journal Article
Open access
PDF file
SVSerena Vickers
Serena Vickers
MBMatthew Bernier
Matthew Bernier
Stephen Christopher ZambrzyckiStephen Christopher Zambrzycki
Stephen Christopher Zambrzycki
Facundo M. FernándezFacundo M. Fernández
Facundo M. Fernández
PNPaul Newton
Paul Newton
CCCeline Caillet
Celine Caillet
Background Poor quality medicines have devastating consequences. A plethora of innovative portable devices to screen for poor quality medicines has become available, leading to hope that they could empower medicine inspectors and enhance surveillance. However, information comparing these new technologies is woefully scarce. Methods We undertook a systematic review of Embase, PubMed, Web of Science and SciFinder databases up to 30 April 2018. Scientific studies evaluating the performances/abilities of portable devices to assess any aspect of the quality of pharmaceutical products were included. Results Forty-one devices, from small benchtop spectrometers to ‘lab-on-a-chip’ single-use devices, with prices ranging from US$20 000, were included. Only six devices had been field-tested (GPHF-Minilab, CD3/CD3+, TruScan RM, lateral flow dipstick immunoassay, CBEx and Speedy Breedy). The median (range) number of active pharmaceutical ingredients (APIs) assessed per device was only 2 (1–20). The majority of devices showed promise to distinguish genuine from falsified medicines. Devices with the potential to assay API (semi)-quantitatively required consumables and were destructive (GPHF-Minilab, PharmaChk, aPADs, lateral flow immunoassay dipsticks, paper-based microfluidic strip and capillary electrophoresis), except for spectroscopic devices. However, the 10 spectroscopic devices tested for their abilities to quantitate APIs required processing complex API-specific calibration models. Scientific evidence of the ability of the devices to accurately test liquid, capsule or topical formulations, or to distinguish between chiral molecules, was limited. There was no comment on cost-effectiveness and little information on where in the pharmaceutical supply chain these devices could be best deployed. Conclusion Although a diverse range of portable field detection devices for medicines quality screening is available, there is a vitally important lack of independent evaluation of the majority of devices, particularly in field settings. Intensive research is needed in order to inform national medicines regulatory authorities of the optimal choice of device(s) to combat poor quality medicines.

3 May 2016 in Expert Review of Anti-infective Therapy
Verified
Journal Article
Closed access
PNPaul Newton
Paul Newton
CCCeline Caillet
Celine Caillet
PGPhilippe J. Guerin
Philippe J. Guerin
Malaria remains a major public health problem for most of the world. The tragedy remains that many more malaria patients would survive if they had timely access to good quality, affordable and effi...

30 September 2021 in PLOS Neglected Tropical Diseases
Verified
Journal Article
Open access
PDF file
Stephen Christopher ZambrzyckiStephen Christopher Zambrzycki
Stephen Christopher Zambrzycki
CCCeline Caillet
Celine Caillet
SVSerena Vickers
Serena Vickers
MBMarcos Bouza
Marcos Bouza
DDDavid V. Donndelinger
David V. Donndelinger
Facundo M. FernándezFacundo M. Fernández
Facundo M. Fernández
Background: Post-market surveillance is a key regulatory function to prevent substandard and falsified (SF) medicines from being consumed by patients. Field deployable technologies offer the potential for rapid objective screening for SF medicines.Methods and findings: We evaluated twelve devices: three near infrared spectrometers (MicroPHAZIR RX, NIR-S-G1, Neospectra 2.5), two Raman spectrometers (Progeny, TruScan RM), one mid-infrared spectrometer (4500a), one disposable colorimetric assay (Paper Analytical Devices, PAD), one disposable immunoassay (Rapid Diagnostic Test, RDT), one portable liquid chromatograph (C-Vue), one microfluidic system (PharmaChk), one mass spectrometer (QDa), and one thin layer chromatography kit (GPHF-Minilab). Each device was tested with a series of field collected medicines (FCM) along with simulated medicines (SIM) formulated in a laboratory. The FCM and SIM ranged from samples with good quality active pharmaceutical ingredient (API) concentrations, reduced concentrations of API (80% and 50% of the API), no API, and the wrong API. All the devices had high sensitivities (91.5 to 100.0%) detecting medicines with no API or the wrong API. However, the sensitivities of each device towards samples with 50% and 80% API varied greatly, from 0% to 100%. The infrared and Raman spectrometers had variable sensitivities for detecting samples with 50% and 80% API (from 5.6% to 50.0%). The devices with the ability to quantitate API (C-Vue, PharmaChk, QDa) had sensitivities ranging from 91.7% to 100% to detect all poor quality samples. The specificity was lower for the quantitative C-Vue, PharmaChk, & QDa (50.0% to 91.7%) than for all the other devices in this study (95.5% to 100%).Conclusions: The twelve devices evaluated could detect medicines with the wrong or none of the APIs, consistent with falsified medicines, with high accuracy. However, API quantitation to detect formulations similar to those commonly found in substandards proved more difficult, requiring further technological innovation.

1 August 2022 in BMJ Global Health
Verified
Journal Article
Open access
PDF file
VVVayouly Vidhamaly
Vayouly Vidhamaly
KBKonnie Bellingham
Konnie Bellingham
PNPaul Newton
Paul Newton
CCCeline Caillet
Celine Caillet
Objective Substandard and falsified (SF) veterinary medicines affect animal health, agricultural production and food security and will influence antimicrobial resistance (AMR) in both animals and humans. Yet, our understanding of their extent and impact is poor. We assess the available public domain evidence on the epidemiology of SF veterinary medicines, to better understand their prevalence and distribution and their public health impact on animals and humans. Methods Searches were conducted in Embase, PubMed, MEDLINE, Global Health, Web of Science, CAB Abstracts, Scopus, Google Scholar, Google and websites with interest in veterinary medicines quality up to 28 February 2021. Identified articles in English and French were screened for eligibility. The Medicine Quality Assessment Reporting Guidelines were used to assess the quality of prevalence surveys. Results Three hundred and fourteen publications were included with a failure frequency (the percentage of samples that failed at least one quality test) of 6.5% (2335/35 733). The majority of samples were from post-marketing surveillance by medicines regulatory authorities of the Republic of Korea and China. A small proportion (3.5%) of samples, all anti-infectives, were from 20 prevalence surveys, with more than half (53.1%, 662/1246) collected in low-income and lower middle-income countries in Africa and Asia. The prevalence survey sample size ranged from 4 to 310 samples (median (Q1–Q3): 50 (27–80)); 55.0% of surveys used convenience outlet sampling methods. In 20 prevalence surveys more than half of the samples (52.0%, 648/1246) failed at least one quality test. The most common defects reported were out-of-specification active pharmaceutical ingredient(s) (API) content, failure of uniformity of units and disintegration tests. Almost half of samples (49.7%, 239/481) that failed API content tests contained at least one of the stated APIs below pharmacopoeial limits. Fifty-two samples (4.2% of all samples) contained one or more incorrect API. One hundred and twenty-three publications described incidents (recalls/seizures/case reports) of SF veterinary medicines in 29 countries. Conclusion The data suggest that SF veterinary products are likely to be a serious animal and public health problem that has received limited attention. However, few studies of SF veterinary medicines are available and are geographically restricted. Lower API content and disintegration/dissolution than recommended by pharmacopoeial standards risks treatment failure, animal suffering and contribute to AMR. Our findings highlight the need of more research, with robust methodology, to better inform policy and implement measures to assure the quality of veterinary medicines within supply chains. The mechanism and impact of SF veterinary products on animal and human health, agricultural production, their economy and AMR need more transdisciplinary research.

24 September 2019 in BMJ Global Health
Verified
Journal Article
Open access
PDF file
KSKartika Saraswati
Kartika Saraswati
CSChanvilay Sichanh
Chanvilay Sichanh
PNPaul Newton
Paul Newton
CCCeline Caillet
Celine Caillet
Background The global prevalence of diabetes mellitus is increasing alarmingly. However, the quality of vital medicines and medical products used to treat and monitor diabetes remains uncertain but of potential great public health significance. Here, we review the available evidence on the quality of antidiabetic medicines and supplies for self-monitoring of blood glucose (SMBG) and discuss their potential impact for the patients and society. Methods Searches were conducted in PubMed, Embase, Google Scholar, Google and relevant websites in English and French. The Medicine Quality Assessment Reporting Guideline (MEDQUARG) was used to assess the quality of medicine quality surveys. Results 52 publications on the quality of antidiabetic medicines, including 5 medicine quality prevalence surveys and 20 equivalence studies, were analysed. The prevalence surveys and equivalence studies included 674 samples of which 73 (10.8%) were of poor quality. The median (Q1–Q3) concordance with MEDQUARG items was 30.8% (19.2%–42.3%). No prevalence surveys on SMBG supplies’ quality were found, but 29 publications, including falsified products and incorrect results due to strip degradation or contamination, were identified. Conclusion There is little accessible evidence on the quality of antidiabetic medicines and SMBG supplies. Surveys were poorly designed and reported, making data aggregation and interpretation problematic. Despite these caveats, these results suggest that there are important issues with the quality of medical products for diabetes that need focused monitoring. There is an urgent need to achieve consensus protocols for designing, conducting and reporting medical product quality surveys. PROSPERO registration number CRD42016039841.