Broadband seismometers, ground-based Global Navigation Satellite Systems (GNSS), and magnetometers that were located within an epicentral distance of approximately 150 km consistently observed the novel anomalous behaviors of the common-mode ground vibrations approximately 5–10 days before the M6.6 Meinong earthquake in Taiwan. The common-mode ground vibrations with amplitudes near 0.1 m at frequencies ranging from 8 × 10−5 to 2 × 10−4 Hz were generated near the region close to the epicenter of the impending earthquake. The common-mode vibrations were consistently observed in seismic and GNSS data associated with five other earthquakes in four distinct areas. The results reveal that the common-mode vibrations could be a typical behavior before earthquakes. The causal mechanism of common-mode vibrations can be attributed to crustal resonance excitations before fault dislocations occur. Potential relationships with other pre-earthquake anomalies suggest that the common-mode vibrations could be ground motion before earthquakes, which was investigated for a significant length of time.
Rock temperature reflects the adjustment in crustal stress, and the fluctuation of ionospheric electron concentration is closely related to short-term disturbances of the stress field. Their coupling may reveal short-term effects before strong earthquakes. This study explores the rock temperature changes and mechanical-electrical coupling in the lithosphere–ionosphere before the Jiashi Ms6.4 earthquake on 19 January 2020. The observed data were detrended by general polynomial piecewise fitting; three observation points within 150 km of the epicenter were found to show significant temperature fluctuations in the 15 days before the earthquake. The peak occurred synchronously five days before the earthquake, and the variation range was approximately 10−3 orders of magnitude. Five days before the earthquake, the electromagnetic satellite Zhangheng-1 synchronously observed an anomalous electron concentration in orbit near the epicenter, with a maximum value of 2.01 × 1010 m−3. The loading/unloading response ratio (LURR) was calculated using small earthquakes within 100 km of the epicenter; it showed that the large changes in rock temperature and the ionosphere occurred at high LURR, indicating high-stress accumulation in the region. Various anomalies appeared simultaneously and may indicate fault rupture, which may be caused by an acoustic-gravity wave, indicating a synchronous coupling between the lithosphere atmosphere and the ionosphere.
The coseismic geothermal changes of ground temperature observed at observatories near the epicenter of the 2020 Jiashi Ms = 6.4 earthquake in China, provide a unique opportunity to study heat generation and conduction in rock. Here, evolutions of rock temperature at the Xikeer, Jiashizongchang, and Gedaliang observatories, which are located at epicentral distances of 1.4, 27.42, and 50 km respectively, were analyzed. Significant coseismic geothermal changes of 0.0432 °C were observed at the Xikeer observatory at the depth of 33.38 m, at which clear diurnal variations can be observed. Smaller changes of ~0.0001 °C were observed at the depths of 12.3 and 22.8 m at the Xikeer observatory and 22.3 m at the Jiashizongchang observatory. The stress transfer induced by the coseismic rupture induced a rise in local ground temperature, but the magnitude of the change was relatively small. The larger amplitude change at the Xikeer observatory was caused by fluid infiltration. We note that diurnal variation has been recorded at the Gedaliang observatory, but the coseismic response is no longer in existence. The temperature increases at the hypocentral area were higher than expected in the ground due to the coseismic stress transfer, but the change attenuated rapidly with distance.
Hydraulic properties of fault zones are important to understanding the pore pressure development and fault stability. In this work, we examined the relationship between water level changes caused by the 2008 Wenchuan Mw 7.9 earthquake and faults using four wells with the same lithology around the Three Gorges Dam, China. Two of the wells penetrating the fault damage zones recorded sustained water level changes, while the other two wells that are not penetrating any fault damage zones recorded transient water level changes. The phase shift and tidal factor calculated from water level, a proxy of permeability and storage coefficient, revealed that both the permeability and storage coefficient changed in the two wells penetrating the fault damage zones, while the other two wells not penetrating the fault damage zone did not show any change in permeability and storage coefficient. Thus, we tentatively suggest that faults may play an important controlling role on earthquake-induced hydrologic changes because the detrital or clogging components in the fractures may be more easily removed by seismic waves.
On the Longmen Shan thrust belt (LMS) on the eastern margin of Tibet Plateau, the Mw7.9 Wenchuan earthquake occurred in 2008. As for the dynamic cause of the Wenchuan earthquake, many scholars have studied the rheological difference and terrain elevation difference on both sides of the fault. However, previous studies have simplified the LMS as a single listric-reverse fault. In fact, the LMS is composed of four faults with different dip angles in the shallow part, and the faults are Wenchuan-Maoxian fault (WMF), Yingxiu-Beichuan fault (YBF), Guanxian-Jiangyou fault (GJF) and Range Front Thrust (RFT) from west to east. However, the control of the branching structure of these faults on the distribution and accumulation of stress and strain during the seismogenic of the Wenchuan earthquake has not been discussed. In this paper, four viscoelastic finite element models with different fault numbers and combination structures are built to analyze the effect of fault branching structures on the stress distribution and accumulation during the seismogenic of Wenchuan earthquake, and we use geodetic data such as GPS and precise leveling data to constrain our models. At the same time, we also study the influence of the existence of the detachment layer, which is formed by the low-resistivity and low-velocity layer, between the upper and lower crust of the Bayan Har block and the change of its frontal edge position on the stress accumulation and distribution. The results show that the combinations of YBF and GJF is most conducive to the concentration of equivalent stress below the intersection of the two faults, and the accumulated stress on GJF is shallower than that on YBF, which means that more stress is transferred to the surface along GJF; and the existence of a detachment layer can effectively promote the accumulation of stress at the bottom of YBF and GJF, and the closer the frontal edge position of the detachment layer is to the LMS fault, the more favorable the stress accumulation is. Based on the magnitude of stress accumulation at the bottom of the intersection of YBF and GJF, we speculate that the frontal edge position of the detachment layer may cross YBF and expand eastward.