A new family of robust, non‐toxic, water‐compatible ruthenium(II) vinyl probes allows the rapid, selective and sensitive detection of endogenous carbon monoxide (CO) in live mammalian cells under normoxic and hypoxic conditions. Uniquely, these probes incorporate a viscosity‐sensitive BODIPY fluorophore that allows the measurement of microscopic viscosity in live cells via fluorescence lifetime imaging microscopy (FLIM) while also monitoring CO levels. This is the first example of a probe that can simultaneously detect CO alongside small viscosity changes in organelles of live cells.
28 November 2017 in Journal of the American Chemical Society
A two-photon fluorescent probe based on a ruthenium(II) vinyl complex is capable of selectively detecting carbon monoxide in cells and ex vivo using mice with a subcutaneous air pouch as a model for inflammation. This probe combines highly selective and sensitive ex vivo detection of endogenous CO in a realistic model with facile, inexpensive synthesis, and displays many advantages over the widely used palladium-based systems.
An overview of the design of chromo-fluorogenic probes for the detection of carbon monoxide and their application to CO sensing in air, solution and in cells.
2 March 2014 in ACS Sustainable Chemistry & Engineering
The room-temperature ionic liquid, [C4C1im][HSO4], provides a multi-faceted medium in which to convert fructose to the versatile chemical building block, 5-hydroxymethylfurfural (HMF). A range of metal salts have been investigated in order to establish some of the properties required for the optimization of this process. This has led to almost quantitative conversion of fructose to 5-HMF in a system that is both selective for the desired product, less energy intensive, and more environmentally benign than the commercial process.
4 August 2014 in Journal of the American Chemical Society
The chromo-fluorogenic detection of carbon monoxide in air has been achieved using a simple, inexpensive system based on ruthenium(II). This probe shows exceptional sensitivity and selectivity in its sensing behavior in the solid state. A color response visible to the naked eye is observed at 5 ppb of CO, and a remarkably clear color change occurs from orange to yellow at the onset of toxic CO concentrations (100 ppm) in air. Even greater sensitivity (1 ppb) can be achieved through a substantial increase in turn-on emission fluorescence in the presence of carbon monoxide, both in air and in solution. No response is observed with other gases including water vapor. Immobilization of the probe on a cellulose strip allows the system to be applied in its current form in a simple optoelectronic device to give a numerical reading and/or alarm.