James Wilton-Ely

Dr. James Wilton-Ely

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2008 in Inorganic Chemistry
Verified
Journal Article
Closed access
JWJames Wilton-Ely
James Wilton-Ely
DSDina Solanki
Dina Solanki
EKEdward R. Knight
Edward R. Knight
KHKatherine B. Holt
Katherine B. Holt
ATAmber L. Thompson
Amber L. Thompson
Graeme HogarthGraeme Hogarth
Graeme Hogarth

19 July 2020 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
PDF file
JRJonathan A. Robson
Jonathan A. Robson
MKMarkéta Kubánková
Markéta Kubánková
TBTamzin Bond
Tamzin Bond
RHRian A. Hendley
Rian A. Hendley
AWAndrew J. P. White
Andrew J. P. White
JWJames Wilton-Ely
James Wilton-Ely
A new family of robust, non‐toxic, water‐compatible ruthenium(II) vinyl probes allows the rapid, selective and sensitive detection of endogenous carbon monoxide (CO) in live mammalian cells under normoxic and hypoxic conditions. Uniquely, these probes incorporate a viscosity‐sensitive BODIPY fluorophore that allows the measurement of microscopic viscosity in live cells via fluorescence lifetime imaging microscopy (FLIM) while also monitoring CO levels. This is the first example of a probe that can simultaneously detect CO alongside small viscosity changes in organelles of live cells.

28 November 2017 in Journal of the American Chemical Society
Verified
Journal Article
Open access
CTCristina de la Torre
Cristina de la Torre
ATAnita Toscani
Anita Toscani
CMCristina Marín-Hernández
Cristina Marín-Hernández
JRJonathan A. Robson
Jonathan A. Robson
MTM. Carmen Terencio
M. Carmen Terencio
FSFélix Sancenón
Félix Sancenón
A two-photon fluorescent probe based on a ruthenium(II) vinyl complex is capable of selectively detecting carbon monoxide in cells and ex vivo using mice with a subcutaneous air pouch as a model for inflammation. This probe combines highly selective and sensitive ex vivo detection of endogenous CO in a realistic model with facile, inexpensive synthesis, and displays many advantages over the widely used palladium-based systems.

23 March 2016 in Chemical Communications
Verified
Journal Article
Open access
PDF file
CMCristina Marín-Hernández
Cristina Marín-Hernández
ATAnita Toscani
Anita Toscani
FSFélix Sancenón
Félix Sancenón
JWJames Wilton-Ely
James Wilton-Ely
RMRamón Martínez-Máñez
Ramón Martínez-Máñez
An overview of the design of chromo-fluorogenic probes for the detection of carbon monoxide and their application to CO sensing in air, solution and in cells.

2 March 2014 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Open access
SESanan Eminov
Sanan Eminov
JWJames Wilton-Ely
James Wilton-Ely
Jason HallettJason Hallett
Jason Hallett
The room-temperature ionic liquid, [C4C1im][HSO4], provides a multi-faceted medium in which to convert fructose to the versatile chemical building block, 5-hydroxymethylfurfural (HMF). A range of metal salts have been investigated in order to establish some of the properties required for the optimization of this process. This has led to almost quantitative conversion of fructose to 5-HMF in a system that is both selective for the desired product, less energy intensive, and more environmentally benign than the commercial process.

4 August 2014 in Journal of the American Chemical Society
Verified
Journal Article
Open access
MMMaría E. Moragues
María E. Moragues
ATAnita Toscani
Anita Toscani
FSFélix Sancenón
Félix Sancenón
RMRamón Martínez-Máñez
Ramón Martínez-Máñez
AWAndrew J. P. White
Andrew J. P. White
JWJames Wilton-Ely
James Wilton-Ely
The chromo-fluorogenic detection of carbon monoxide in air has been achieved using a simple, inexpensive system based on ruthenium(II). This probe shows exceptional sensitivity and selectivity in its sensing behavior in the solid state. A color response visible to the naked eye is observed at 5 ppb of CO, and a remarkably clear color change occurs from orange to yellow at the onset of toxic CO concentrations (100 ppm) in air. Even greater sensitivity (1 ppb) can be achieved through a substantial increase in turn-on emission fluorescence in the presence of carbon monoxide, both in air and in solution. No response is observed with other gases including water vapor. Immobilization of the probe on a cellulose strip allows the system to be applied in its current form in a simple optoelectronic device to give a numerical reading and/or alarm.