Max Dullaart

Mr. Max Dullaart

UMC Utrecht
+1
orcid

Research Focus & Metrics

Representative Publications

View All Publications
24 October 2021 in Brain Sciences
Verified
Journal Article
Open access
PDF file
KAKelly K. S. Assouly
Kelly K. S. Assouly
MDMax J. Dullaart
Max J. Dullaart
RSRobert J. Stokroos
Robert J. Stokroos
BDBas van Dijk
Bas van Dijk
ISInge Stegeman
Inge Stegeman
ASAdriana L Smit
Adriana L Smit
Several electrical stimulation patterns of the auditory nerve have been described for tinnitus relief, but there is no consensus on the most effective stimulation pattern. Therefore, we aim to systematically review the literature on the effect of intra- and extracochlear electrical stimulation patterns as a treatment option for patients with tinnitus. Only studies on intra- and extracochlear electrical stimulation for patients with tinnitus were included if the stimulation used did not concern standardized CI stimulation patterns to primarily rehabilitate hearing loss as intervention. A total of 34 studies met the inclusion criteria, with 10 studies (89 patients) on intracochlear electrical stimulation and 25 studies on extracochlear electrical stimulation (1109 patients). There was a high to medium risk of bias in 22 studies, especially due to lack of a non-exposed group and poor selection of the exposed group. All included studies showed subjective tinnitus improvement during or after electrical stimulation, using different stimulation patterns. Due to methodological limitations and low reporting quality of the included studies, the potential of intra- and extracochlear stimulation has not been fully explored. To draw conclusions on which stimulation patterns should be optimized for tinnitus relief, a deeper understanding of the mechanisms involved in tinnitus suppression is needed.

12 July 2023 in Laryngoscope Investigative Otolaryngology
Verified
Journal Article
Open access
EBEsther E. Blijleven
Esther E. Blijleven
DFDenise Fuchten
Denise Fuchten
MDMax J. Dullaart
Max J. Dullaart
RSRobert J. Stokroos
Robert J. Stokroos
HTHenricus G. X. M. Thomeer
Henricus G. X. M. Thomeer
Inge WegnerInge Wegner
Inge Wegner
Objective: What are the electrogustometer's (EGM) validity, reliability, and diagnostic accuracy in assessing taste sensation in adults compared to other taste tests?Data Sources: PubMed Medline, Elseviers's Embase, and the six databases of Cochrane Library.Methods: We conducted a systematic search on December 20, 2022, consisting of synonyms for EGM. We considered randomized controlled trials and observational studies with original data for inclusion if they included adults who underwent electrogustometry. Articles were excluded if no analysis regarding validity, reliability, or diagnostic accuracy had been performed or if these analyses could not be performed with the published data.Results: Nineteen articles discussing 18 studies were included for data extraction. The included studies carry a high risk of bias. Overall, the association between a variety of reference taste tests and EGM was moderate or weak with correlation coefficients ranging from −0.51 to 0.40 with one outlier of −0.74 found in one study correlating EGM and taste solutions. Test–retest reliability was good with reported correlation coefficients between 0.78 and 1.0. The sensitivity, specificity, PPV, and NPV of EGM in identifying abnormal taste function varied widely between the four studies on diagnostic accuracy.Conclusion: The included studies in this review lack the required standards regarding study design to draw firm conclusions about the validity, reliability, and diagnostic accuracy of the EGM. Future research is needed to assess these measurement properties. Based on the reported results, we would not recommend using the EGM as a screening test for taste disturbance in clinical practice.Level of Evidence: NA.

8 October 2025 in Head & Neck
Verified
Journal Article
Open access
MDMax J. Dullaart
Max J. Dullaart
SVSebastiaan R. de Vreugd
Sebastiaan R. de Vreugd
MLMaartje Leemans
Maartje Leemans
RSRob van Son
Rob van Son
AMArjan Malekzadeh
Arjan Malekzadeh
RDRichard Dirven
Richard Dirven
Background: The percentage of daily automatic speaking valve use (AU) in laryngectomized patients has remained at ~25% since their invention. To increase this percentage, understanding the performance of existent devices is essential. Therefore, we reviewed studies reporting AU, fixation device lifetime (FDL), compliance, and voice and speech assessment outcomes (VSAOs). Methods: Studies published until 23 April 2025 were included. Quality assessment was performed using RoB2, ROBINS‐I, and JBI tools. Results: Twenty studies were included, which were of poor methodological quality. AU and FDL were 3–13.25 h/day and 0.17–24 h/day. Baseline daily ASV compliance rate was 25%, increasing short‐term but decreasing long‐term. Reasons for non‐compliance were inadequate fixation, skin problems, and voicing being too tiresome. There were no significant differences across ASVs in VSAOs. Conclusion: No single ASV or fixation device outperformed others. Personalized approaches, tailored to ASV experience, tracheostoma anatomy, and patient needs, may increase AU, FDL, and long‐term compliance.

3 December 2025 in European Radiology Experimental
Verified
Journal Article
Open access
MDMax Johannes Dullaart
Max Johannes Dullaart
MAMaarten Jan Antony van Alphen
Maarten Jan Antony van Alphen
ASAnnelieke Boudina Schoen
Annelieke Boudina Schoen
MBMargje Bertine Buitenhuis
Margje Bertine Buitenhuis
LBLoes Margaretha Marie Braun
Loes Margaretha Marie Braun
RDRichard Dirven
Richard Dirven
Background: To increase the number of patients who can speak hands-free after total laryngectomy, we aim to assess the viability of the manubrium sterni bone (MSB) for bone implantation. Materials and methods: This retrospective cross-sectional study was conducted at the Department of Head and Neck Surgery of the Netherlands Cancer Institute in Amsterdam, the Netherlands, after approval by its Institutional Review Board. We included CT scans of 25 males and 24 females aged 53 to 88 years, and measured MSB morphometry and density, soft tissue thickness (STT), and bone surface slope, and classified the MSB. Heat maps were created to identify potential implant locations. Results: Median MSB height was 50.7 [95% confidence interval 49.4–53.4] mm, and mean thickness ranged from 8.7 [8.3–9.2] to 13.1 [12.7–13.6] mm. Mean width ranged from 53.2 [51.1–55.4] to 57.1 [55.3–59.1] mm. Significantly greater values of thickness and width were found in males. Body height had a significant positive effect on thickness and width measured at the thickest level. Median STT was 14.4 [12.7–17.4] mm, on which BMI had a significant positive effect. The trapezoid was the most common shape. Mean densities were 325 and 60 HU for cortical and cancellous bone, respectively, and cancellous density was significantly higher in males. As such, the MSB is most similar to the posterior maxilla with regard to implantation. Conclusion: In theory, the MSB is able to support a combination of three to four 6-mm implants, or of one 6-mm to 8-mm and two 10-mm implants, placed in a linear, triangular or diamond-shaped arrangement. Relevance statement: This study addresses knowledge gaps regarding the possibility of fixation methods of hands-free speaking valves offering greater stability than conventional methods. Radiological assessment of CT scans of the manubrium sterni bone demonstrates its potential as an implantation site, although a thorough preimplantation workup of individual anatomy is imperative. Key Points: This is the first study that analyzes the manubrium sterni bone three-dimensionally and assesses its potential as a bone implantation site. We found that it has low cortical and cancellous bone density, which makes it most similar to the posterior maxilla. The Manubrium sterni bone is suitable for implantation, although a preimplantation assessment of individual anatomy is imperative. Graphical