Chung Hwang

Prof. Chung Hwang

Professor
orcid

Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
SKSoo-Yeon Kim
Soo-Yeon Kim
Yooseok ShinYooseok Shin
Yooseok Shin
HJHwi-Dong Jung
Hwi-Dong Jung
CHChung Hwang
Chung Hwang
HBHyoung-Seon Baik
Hyoung-Seon Baik
JCJung Yul Cha
Jung Yul Cha

1 March 2008 in The Angle Orthodontist
Verified
Journal Article
Closed access
SLSeon-A. Lim
Seon-A. Lim
JCJung Yul Cha
Jung Yul Cha
CHChung Hwang
Chung Hwang
Objective: To determine the variation in the insertion torque of orthodontic miniscrews according to the screw length, diameter, and shape. Materials and Methods: The maximum insertion torque (MIT) was measured using a torque tester at a constant speed of 3 rotations per minute. Cylindrical and taper type of miniscrews (Biomaterials Korea Inc, Seoul, Korea) with different lengths, diameters, and pitches were tested. Results: The results showed that the insertion torque significantly increased with increasing screw length (P < .01). In particular, there was a significant increase in torque with increasing screw length and diameter (P < .01). An analysis of the serial insertion torque of miniscrews revealed the cylindrical type screw to have much higher insertion torque at the incomplete screw thread, while the taper type screw showed a much higher insertion torque at the final inclination part of the screw thread. The insertion torque was affected by the outer diameter, length, and shape in that order. Conclusions: An increase in screw diameter can efficiently reinforce the initial stability of the miniscrew, but the proximity of the root at the implanted site should be considered.

1 October 2001 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
CHChung Hwang
Chung Hwang
JSJi-Soo Shin
Ji-Soo Shin
JCJung Yul Cha
Jung Yul Cha

1 January 2010 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
JCJung Yul Cha
Jung Yul Cha
JKJae-Kyoung Kil
Jae-Kyoung Kil
TYTae-Min Yoon
Tae-Min Yoon
CHChung Hwang
Chung Hwang

1 January 2017 in The Korean Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
YKYun-Jin Koo
Yun-Jin Koo
Sung-Hwan ChoiSung-Hwan Choi
Sung-Hwan Choi
BKByeong-Tak Keum
Byeong-Tak Keum
HYHyung-Seog Yu
Hyung-Seog Yu
CHChung Hwang
Chung Hwang
KLKee-Joon Lee
Kee-Joon Lee
Koo YJ, et al. Korean J Orthod. 2017 May;47(3):167-175. https://doi.org/10.4041/kjod.2017.47.3.167

1 November 2007 in The Angle Orthodontist
Verified
Journal Article
Closed access
YSYoung-Youn Song
Young-Youn Song
JCJung Yul Cha
Jung Yul Cha
CHChung Hwang
Chung Hwang
Objective: To evaluate the effect of cortical bone thickness on the maximum insertion and removal torque of different types of self-drilling mini-screws and to determine if torque depends on the screw design. Materials and Methods: Three different types of self-drilling mini-screws (cylindrical type [Cl], taper type [Ta], taper type [Tb]) were inserted with the use of a driving torque tester at a constant speed of 3 rotations per minute. Experimental bone blocks with different cortical bone thicknesses were used as specimens. Results: Differences in the cortical bone thickness had little effect on the maximum insertion and removal torque in Cl. However, with Ta and Tb, the maximum insertion torque increased as the cortical bone thickness increased. The maximum insertion torque of Tb was highest in all situations, followed by Ta and Tb, in that order. Cl showed less torque loss in all cortical bone thicknesses and a longer removal time compared to Ta or Tb. There were significant relationships between cortical bone thickness, maximum insertion and removal torque, and implantation time in each type of self-drilling mini-screw. Conclusion: Since different screw designs showed different insertion torques with increases in cortical bone thickness, the suitable screw design should be selected according to the cortical thickness at the implant site.