Nikunj Bhagat

Mr. Nikunj Bhagat


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2016 in Frontiers in Neuroscience
Verified
Journal Article
Open access
NBNikunj Bhagat
Nikunj Bhagat
AVAnusha Venkatakrishnan
Anusha Venkatakrishnan
BABerdakh Abibullaev
Berdakh Abibullaev
EAEdward J. Artz
Edward J. Artz
NYNuray Yozbatiran
Nuray Yozbatiran
Jose L Contreras-VidalJose L Contreras-Vidal
Jose L Contreras-Vidal
This study demonstrates the feasibility of detecting motor intent from brain activity of chronic stroke patients using an asynchronous electroencephalography (EEG)-based brain machine interface (BMI). Intent was inferred from movement related cortical potentials (MRCPs) measured over an optimized set of EEG electrodes. Successful intent detection triggered the motion of an upper-limb exoskeleton (MAHI Exo-II), to guide movement and to encourage active user participation by providing instantaneous sensory feedback. Several BMI design features were optimized to increase system performance in the presence of single-trial variability of MRCPs in the injured brain: 1) an adaptive time window was used for extracting features during BMI calibration; 2) training data from two consecutive days were pooled for BMI calibration to increase robustness to handle the day-to-day variations typical of EEG, and 3) BMI predictions were gated by residual electromyography (EMG) activity from the impaired arm, to reduce the number of false positives. This patient-specific BMI calibration approach can accommodate a broad spectrum of stroke patients with diverse motor capabilities. Following BMI optimization on day 3, testing of the closed-loop BMI-MAHI exoskeleton, on 4th and 5th days of the study, showed consistent BMI performance with overall mean true positive rate (TPR) = 62.7 +/- 21.4 % on day 4 and 67.1 +/- 14.6 % on day 5. The overall false positive rate (FPR) across subjects was 27.74 +/- 37.46 % on day 4 and 27.5 +/- 35.64 % on day 5; however for two subjects who had residual motor function and could benefit from the EMG-gated BMI, the mean FPR was quite low (< 10 %). On average, motor intent was detected -367 +/- 328 ms before movement onset during closed-loop operation. These findings provide evidence that closed-loop EEG-based BMI for stroke patients can be designed and optimized to perform well across multiple days without system recalibration.

1 January 2020 in NeuroImage: Clinical
Verified
Journal Article
Open access
NBNikunj Bhagat
Nikunj Bhagat
NYNuray Yozbatiran
Nuray Yozbatiran
JSJennifer L. Sullivan
Jennifer L. Sullivan
RPRuta Paranjape
Ruta Paranjape
CLColin Losey
Colin Losey
JCJose L. Contreras-Vidal
Jose L. Contreras-Vidal
• Motor intention based arm training targets activity-dependent neuroplasticity. • 80% of stroke participants recovered clinically relevant functional movements. • Ipsi-lesional, delta-band EEG activity was highly correlated with motor recovery. • Results suggest higher activation of ipsi-lesional hemisphere post-intervention.

1 August 2014 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
NBNikunj Bhagat
Nikunj Bhagat
JFJames French
James French
AVAnusha Venkatakrishnan
Anusha Venkatakrishnan
NYNuray Yozbatiran
Nuray Yozbatiran
GFGerard E Francisco
Gerard E Francisco
Jose L Contreras-VidalJose L Contreras-Vidal
Jose L Contreras-Vidal
Stroke can be a source of significant upper extremity dysfunction and affect the quality of life (QoL) in survivors. In this context, novel rehabilitation approaches employing robotic rehabilitation devices combined with brain-machine interfaces can greatly help in expediting functional recovery in these individuals by actively engaging the user during therapy. However, optimal training conditions and parameters for these novel therapeutic systems are still unknown. Here, we present preliminary findings demonstrating successful movement intent detection from scalp electroencephalography (EEG) during robotic rehabilitation using the MAHI Exo-II in an individual with hemiparesis following stroke. These findings have strong clinical implications for the development of closed-loop brain-machine interfaces to robotic rehabilitation systems.

12 February 2021 in IEEE Open Journal of Engineering in Medicine and Biology
Verified
Journal Article
Open access
APAndrew Y. Paek
Andrew Y. Paek
JBJustin A. Brantley
Justin A. Brantley
ARAkshay Sujatha Ravindran
Akshay Sujatha Ravindran
KNKevin Nathan
Kevin Nathan
YHYongtian He
Yongtian He
Jose L Contreras-VidalJose L Contreras-Vidal
Jose L Contreras-Vidal
The control and manipulation of various types of end effectors such as powered exoskeletons, prostheses, and ‘neural’ cursors by brain-machine interface (BMI) systems has been the target of many research projects. A seamless “plug and play” interface between any BMI and end effector is desired, wherein similar user's intent cause similar end effectors to behave identically. This report is based on the outcomes of an IEEE Standards Association Industry Connections working group on End Effectors for Brain-Machine Interfacing that convened to identify and address gaps in the existing standards for BMI-based solutions with a focus on the end-effector component. A roadmap towards standardization of end effectors for BMI systems is discussed by identifying current device standards that are applicable for end effectors. While current standards address basic electrical and mechanical safety, and to some extent, performance requirements, several gaps exist pertaining to unified terminologies, data communication protocols, patient safety and risk mitigation.

1 May 2019
Verified
Conference Paper
Closed access
AMAriana Mirian
Ariana Mirian
NBNikunj Bhagat
Nikunj Bhagat
CSCaitlin Sadowski
Caitlin Sadowski
AFAdrienne Porter Felt
Adrienne Porter Felt
SSStefan Savage
Stefan Savage
GVGeoffrey M. Voelker
Geoffrey M. Voelker
Deprecation – signaling that a function is becoming obsolete in the near future – is necessary for the web ecosystem. However, an unsuccessful deprecation can lead to pain for both developers and end-users. In this paper, we analyze web feature deprecations with the goal of improving Chrome's deprecation process by balancing the need for deprecation and minimizing user pain. We produce a taxonomy of reasons why developers want to deprecate web features and a deprecation methodology for deciding when it is safe to deprecate a web feature. We also discuss the challenges faced during the deprecation process.

9 November 2020 in medRxiv
Verified
Preprint
Open access
PDF file
SCSantosh Chandrasekaran
Santosh Chandrasekaran
SBStephan Bickel
Stephan Bickel
JHJose L Herrero
Jose L Herrero
JKJoo-Won Kim
Joo-Won Kim
NMNoah Markowitz
Noah Markowitz
AMAshesh D Mehta
Ashesh D Mehta
Paralysis and neuropathy, affecting millions of people worldwide, can be accompanied by a significant loss of somatosensation. With tactile sensation being central to achieving dexterous movement, brain-computer interface (BCI) researchers have explored the use of intracortical electrical stimulation to restore sensation to the hand. However, current approaches have been restricted to stimulating the gyral areas of the brain while functional imaging suggests that the representation of fingertips lie predominantly in the sulcal regions. Here we show, for the first time, highly focal percepts can be evoked in the fingertips of the hand through electrical stimulation of the sulcal areas of the brain. To this end, we mapped and compared sensations elicited in the hand by stimulating both gyral and sulcal areas of the human primary somatosensory cortex (S1). Two participants with intractable epilepsy were implanted with stereoelectroencephalography (SEEG) and high-density electrocorticography (HD-ECoG) electrodes in S1 guided by high-resolution functional imaging. Using myelin content and cortical thickness maps developed by the Human Connectome Project, we elucidated the specific sub-regions of S1 where focal percepts were evoked. Within-participant comparisons showed that sulcal stimulation using SEEG electrodes evoked percepts that are significantly more focal, with 80% less area of spread (p=0.02) and localized to the fingertips more often than in gyral stimulation via HD-ECoG electrodes. Finally, sulcal locations exhibiting repeated modulation patterns of high-frequency neural activity during mechanical tactile stimulation of the hand showed the same somatotopic correspondence as sulcal stimulation. These findings show that minimally-invasive sulcal stimulation could lead to a clinically viable approach to restoring sensation in those living with sensory impairment. Significance Intracortical or cortical surface stimulation of the primary somatosensory cortex (S1) offers the promise of restoring somatotopically-relevant sensation in people with sensory impairment. However, evoking percepts in the fingertips has been challenging as their representation has been shown to be predominantly located within sulcal regions of S1 – inaccessible by these stimulation approaches. We evoked highly focal percepts in the fingertips of the hand by stimulating the sulcal regions of S1 in people with intractable epilepsy using stereoelectroencephalography (SEEG) depth electrodes. Sensory percepts in the fingertips were more focal and more frequently evoked by SEEG electrodes than by high-density electrocorticography (HD-ECoG) grids evidenced by within-participant comparisons. Our results suggest that fingertip representations are more readily targeted within the sulcal regions. SEEG electrodes potentially offer a clinically viable approach to access the sulcal regions for sensory neuroprostheses that can aid dexterous motor control.