Exosomes are extracellular vehicles (EVs) that encapsulate genomic and proteomic material from the cell of origin that can be used as biomarkers for non-invasive disease diagnostics in point of care settings. The efficient and accurate detection, quantification, and molecular profiling of exosomes are crucial for the accurate identification of disease biomarkers. Conventional isolation methods, while well-established, provide the co-purification of proteins and other types of EVs. Exosome purification, characterization, and OMICS analysis are performed separately, which increases the complexity, duration, and cost of the process. Due to these constraints, the point-of-care and personalized analysis of exosomes are limited in clinical settings. Lab-on-a-chip biosensing has enabled the integration of isolation and characterization processes in a single platform. The presented review discusses recent advancements in biosensing technology for the separation and detection of exosomes. Fluorescent, colorimetric, electrochemical, magnetic, and surface plasmon resonance technologies have been developed for the quantification of exosomes in biological fluids. Size-exclusion filtration, immunoaffinity, electroactive, and acoustic-fluid-based technologies were successfully applied for the on-chip isolation of exosomes. The advancement of biosensing technology for the detection of exosomes provides better sensitivity and a reduced signal-to-noise ratio. The key challenge for the integration of clinical settings remains the lack of capabilities for on-chip genomic and proteomic analysis.
10 August 2020 in Journal of Thermal Science and Engineering Applications
The design of highly-sensitive thermoelectric microfluidic sensors for the characterization of biochemical processes is an important area of engineering research. This study reports the fabrication of a biosensor with an integrated thermopile and three-dimensional numerical analysis of the critical design parameters that significantly increase the detection sensitivity of the platform. The paper discusses the impact of volumetric flow rate, channel height, material thermal properties, and heat sink on the magnitude of the thermoelectric signal. In the platform understudy, the heat generated by the enzymatic reaction between glucose oxidase-conjugated antibody and glucose is converted to an electric output by an antimony-bismuth thin-film thermopile with a theoretical Seebeck coefficient of 7.14µV mK-1. Since this experimental configuration has been implemented in a variety of biochemical analysis, particular emphasis in this work is maximizing the detection sensitivity of the device. Computational thermal modeling was performed to investigate the impact of channel height (50 µm, 100 µm, 150 µm, and 200 µm), the volumetric flow rate of the substrate (25µL min-1 and 50µL min-1), and the microdevice material (glass, PMMA, and PDMS) on the output of the thermoelectric sensor. Experimental data validated the model and provided an excellent correlation between the predicted and measured voltage output. Results show that fabricating the calorimeter out of materials with lower thermal diffusivity, reducing the channel height, and eliminating the heat sink at the reference junction of the thermopile increases the sensitivity of the platform by 783%.
This study reports 3D numerical analysis and experimental results to identify the optimal operating parameters of the microfluidic co-culture platform with an integrated pressure-controlled valve. This device is expected to be a valuable new tool in a wide range of studies, including basic research on intercellular communication and cell-to-cell interactions. A combination of
This study reports the design, fabrication, and a two-dimensional numerical analysis to identify the optimal operating parameters of a novel microfluidic co-culture platform with an integrated pressure-controlled valve. Replica molding using 3D printed PDMS molds were used for the fabrication of the individual components of the device. Alternation of the position of the PDMS hydraulic valve permits individual manipulation of the cellular microenvironment of the two adjacent cell culture chambers (27.5 mm × 35 mm × 10 mm). The mathematical model analyzes the deflection profile of the valve in the vertical direction as a function of several parameters: valve thicknesses, the pressure exerted by the fluid inside the pressure chamber, and PDMS elasticity determined by the ratio of the elastomer base and the curing reagent. The valve understudy requires a deflection of 0.5 mm to completely isolate the two cell chambers. The combination of the optimal design parameters is identified using numerical analysis. Mathematical simulations show that the deflection of the membrane is inversely proportional to the valve membrane thickness and directly proportional to the pressure exerted by the fluid on the valve.