Lennart Jütte

Mr. Lennart Jütte

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2024 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
LJLennart Jütte
Lennart Jütte
SGSandra González-Villà
Sandra González-Villà
JQJosep Quintana
Josep Quintana
MSMartin Steven
Martin Steven
RGRafael Garcia
Rafael Garcia
Bernhard RothBernhard Roth
Bernhard Roth
Significance: The early detection and accurate monitoring of suspicious skin lesions are critical for effective dermatological diagnosis and treatment, particularly for reliable identification of the progression of nevi to melanoma. The traditional diagnostic framework, the ABCDE rule, provides a foundation for evaluating lesion characteristics by visual examination using dermoscopes. Simulations of skin lesion progression could improve the understanding of melanoma growth patterns.Aim: This study aims to enhance lesion analysis and understanding of lesion progression by providing a simulated potential progression of nevi into melanomas.Approach: The study generates a dataset of simulated lesion progressions, from nevi to simulated melanoma, based on a Cycle-Consistent Adversarial Network (Cycle-GAN) and frame interpolation. We apply an optical flow analysis to the generated dermoscopic image sequences, enabling the quantification of lesion transformation. In parallel, we evaluate changes in ABCDE rule metrics as example to assess the simulated evolution.Results: We present the first simulation of nevi progressing into simulated melanoma counterparts, consisting of 152 detailed steps. The ABCDE rule metrics correlate with the simulation in a natural manner. For the seven samples studied, the asymmetry metric increased by an average of 19%, the border gradient metric increased by an average of 63%, the convexity metric decreased by an average of 3%, the diameter increased by an average of 2%, and the color dispersion metric increased by an average of 45%. The diagnostic value of the ABCDE rule is enhanced through the addition of insights based on optical flow. The outward expansion of lesions, as captured by optical flow vectors, correlates strongly with the expected increase in diameter, confirming the simulation’s fidelity to known lesion growth patterns. The heatmap visualizations further illustrate the degree of change within lesions, offering an intuitive visual proxy for lesion evolution.Conclusion: The achieved simulations of potential lesion progressions could facilitate improved early detection and understanding of how lesions evolve. By combining the optical flow analysis with the established criteria of the ABCDE rule, this study presents a significant advancement in dermatoscopic diagnostics and patient education. Future research will focus on applying this integrated approach to real patient data, with the aim of enhancing the understanding of lesion progression and the personalization of dermatological care.

6 September 2024 in AI
Verified
Journal Article
Open access
PDF file
LJLennart Jütte
Lennart Jütte
NWNing Wang
Ning Wang
MSMartin Steven
Martin Steven
Bernhard RothBernhard Roth
Bernhard Roth
Digital technologies are making their mark in medicine, and especially also in art therapy, offering innovative therapeutic interventions for patients, including those with melanoma skin cancer. However, the integration of novel technologies, such as AI-generated art, brings along ethical, psychological, and technical challenges that are viewed differently among therapists. We aim to gauge art therapists’ views on the ethical, application, and challenge facets of utilizing AI-generated art from medical images in therapy. The focus is on assessing its applicability and limitations for melanoma patients. Art therapists were surveyed via a questionnaire focusing on their experience, digital tool familiarity, and views on AI in therapy, encompassing ethics, benefits, challenges, and applicability for melanoma. Art therapists have already implemented digital technologies and acknowledged potential therapeutic benefits of creating personalized artworks with generative artificial intelligence. Attention needs to be given to technological hurdles and the necessity for supplementary interventions. Views on the method’s adaptability varied, underscoring a need for tailored, patient-focused applications. Art therapists are welcoming AI-generated art as a promising creative therapeutic tool and acknowledge potential therapeutic benefits. There are ethical, technical, and psychological challenges that must be addressed for application in therapeutic sessions. Therapists should navigate AI integration with sensitivity, adhering to ethical norms around consent and privacy. Future studies should show the therapeutic benefit in practice with emphasis on equipping therapists to manage the technical complexities effectively. Furthermore, it is important to ensure that patients can influence the AI output, allowing for creative moments in the process.

21 October 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
LJLennart Jütte
Lennart Jütte
ZYZhiyao Yang
Zhiyao Yang
GSGaurav Sharma
Gaurav Sharma
Bernhard RothBernhard Roth
Bernhard Roth
Dermoscopy is the main tool for early detection of skin cancer. Non-contact dermoscopes often suffer from a small depth of field leading to images of skin topographies with regions that are not in focus. We aim to provide an easy-to-implement focus stacking-based approach to ensure all-in-focus images from a non-contact dermoscope. Further, we aim to extract additional information about the skin topography from the image stacks. The focus stacking procedure itself is implemented in a non-contact dermoscope with an electrically adjustable focus realized by using a tunable liquid lens. We show that all-in-focus imaging is possible for non-contact dermoscopy and deliver a method to extract topographical information for dermatologists from the acquired image stacks. Our finding indicate that the approach can be valuable for non-contact dermoscopic examination as well as for the early detection of skin diseases such as cancer as it possible to derive hyperfocus images and information on the skin topography. With this, we were able to develop a software for the acquisition of the raw image data and its processing into a high resolution hyperresolution dermoscopic image. In the next steps, we plan to apply the approach in the clinical environment for skin cancer diagnostics or imaging of inflammatory skin diseases.

11 December 2019 in Polymers
Verified
Journal Article
Open access
PDF file
DFDierk Fricke
Dierk Fricke
ABAlexander Becker
Alexander Becker
LJLennart Jütte
Lennart Jütte
MBMichael Bode
Michael Bode
DCDominik de Cassan
Dominik de Cassan
Bernhard RothBernhard Roth
Bernhard Roth
Electrospun fiber scaffolds are gaining in importance in the area of tissue engineering. They can be used, for example, to fabricate graded implants to mimic the tendon bone junction. For the grading of the tensile strength of the fiber scaffolds, the orientation of the fibers plays a major role. This is currently measured by hand in scanning electron microscope (SEM) images. In this work, a correlation between polarimetric information generated by measuring the Mueller matrix (MM) and the orientation of the fibers of electrospun fiber scaffolds is reported. For this, the MM of fiber scaffolds, which were manufactured with different production parameters, was measured and analyzed. These data were correlated with fiber orientation and mechanical properties, which were evaluated in an established manner. We found that by measurement of the MM the production parameters as well as the relative orientation of the fibers in space can be determined. Thus, the MM measurement is suitable as an alternative tool for non-contact, non-destructive determination of the production parameters and, thus, the degree of alignment of electrospun fiber scaffolds.

1 November 2024 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
LJLennart Jütte
Lennart Jütte
HPHarshkumar Patel
Harshkumar Patel
Bernhard RothBernhard Roth
Bernhard Roth
The early detection and diagnosis of melanoma, a skin cancer originating from melanocytes, remains a pivotal challenge in dermatology.1 Melanoma is treatable in its early stages but metastasizes to other parts of the body in later stages, making it one of the deadliest forms of skin cancer.2 The incidence of melanoma has been rising steadily over the past decades, becoming a significant public health concern globally.3 The gold standard for diagnosing melanoma is histopathology which is performed on an excised sample of the lesion. Dermoscopy, a non-invasive skin examination technique, is the established imaging tool in the early detection of melanoma, providing dermatologists with enhanced visualization of subsurface skin structures that are not visible to the naked eye. This technique significantly increases the accuracy of melanoma diagnoses by enabling the detailed observation of characteristic features of melanoma lesions.4 However, the presence of hair in dermoscopic images presents a considerable challenge, often obscuring critical details of the skin lesions and potentially leading to misdiagnosis or decreasing the confidence of dermatologists in their diagnosis.5

30 August 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
LJLennart Jütte
Lennart Jütte
GSGaurav Sharma
Gaurav Sharma
HPHarshkumar Patel
Harshkumar Patel
Bernhard RothBernhard Roth
Bernhard Roth
Imaging of the human skin with polarimetric techniques has gained importance in recent years, as the incidence of melanoma, which is the deadliest type of skin cancer, is rising throughout all skin types.1 Beyond the classical skin cancer screening done by a dermatologist with a dermoscope,2 new modalities are being implemented for the early detection of melanoma: polarimetric imaging devices such as Stokes3 or Mueller polarimeters4,5 and machine learning-based computer-aided diagnosis systems6 are among the recently reported approaches. Furthermore, the early detection of melanoma is increasingly profiting from automated registration and analysis.7 In addition, adaptive optics such as adjustable liquid lenses allow for the implementation of autofocus in imaging systems without moving parts.8 However, because the up to 36 images necessary for Mueller matrix (MM) determination9 are typically obtained in acquisition times of 20 to 30 s, depending on the type of the setup,10 unintended body movements of the patient can become a significant limitation. Patient motion can lead to misalignment of the polarimetric images.11 Further, it can induce motion blur, in particular because laser power levels have to be reduced due to laser safety and therefore relatively high exposure times are needed to acquire the MMs. In addition, the motion can add up in cases in which a summation process of the polarimetric data is needed to enhance the signal-to-noise ratio (SNR).11 For example, the registration of scanned polarimetric images for ophthalmology was investigated by Nourrit et al.11 The above-mentioned problems in the MM acquisition can be partly overcome by hardware upgrades, e.g., camera and lens upgrades. However, such upgrades typically rely on complex and costly components.12 Therefore, software solutions represent an alternative approach and promise improved results.