The assessment of oxygen saturation in arterial blood by pulse oximetry (SpO2) is based on the different light absorption spectra for oxygenated and deoxygenated hemoglobin and the analysis of photoplethysmographic (PPG) signals acquired at two wavelengths. Commercial pulse oximeters use two wavelengths in the red and infrared regions which have different pathlengths and the relationship between the PPG-derived parameters and oxygen saturation in arterial blood is determined by means of an empirical calibration. This calibration results in an inherent error, and pulse oximetry thus has an error of about 4%, which is too high for some clinical problems. We present calibration-free pulse oximetry for measurement of SpO2, based on PPG pulses of two nearby wavelengths in the infrared. By neglecting the difference between the path-lengths of the two nearby wavelengths, SpO2 can be derived from the PPG parameters with no need for calibration. In the current study we used three laser diodes of wavelengths 780, 785 and 808 nm, with narrow spectral line-width. SaO2 was calculated by using each pair of PPG signals selected from the three wavelengths. In measurements on healthy subjects, SpO2 values, obtained by the 780–808 nm wavelength pair were found to be in the normal range. The measurement of SpO2 by two nearby wavelengths in the infrared with narrow line-width enables the assessment of SpO2 without calibration.
This paper presents a KGW Raman laser with an external-cavity configuration at the 2 µm region. The Raman laser is pumped by an actively Q-switched Tm:YLF laser, especially designed for this purpose emitting at 1880 nm. Due to the KGW bi-axial properties, the Raman laser is able to lase separately at two different output lines, 2197 nm and 2263 nm. The output energies and pulse durations that were achieved for these two lines are 0.15 mJ/pulse at 21 ns and 0.4 mJ/pulse at 5.4 ns, respectively. To the best of our knowledge, this is the first time that the KGW crystal, which is well known for its wide use in shorter wavelengths, is demonstrated in a Raman laser in the 2 µm region. According to the achieved results and due to the KGW properties, it appears to be a suitable crystal for energy scaling and efficient Raman conversion in this spectral range. An estimation of the Raman gain coefficient for this wavelength is provided as well.
We present an all-passive efficient KGW Raman laser with an external-cavity configuration in the 2 mu m spectral regime. The Raman laser was pumped by a passively Q-switched Tm:YAP laser emitting at 1935 nm. Due to the bi-axial properties of the KGW crystal, the laser exhibits stimulated Raman emission at two separate spectral lines: 2272 nm and 2343 nm. The output energies achieved at these two lines are 340 mu J/pulse and 450 mu J/pulse, accordingly. The seed to Raman laser conversion efficiencies achieved of 19.2% and 23.5%, respectively, are comparable to actively Q-switched laser arrangements. To the best of our knowledge, this is the first time an efficient Raman laser in the 2 mu m regime is demonstrated in a completely passive configuration. (C) 2020 Optical Society of America
A pulsed high energy and narrow bandwidth tunable Tm:YLF laser at the milli-Joule level is demonstrated. The spectral bandwidth was narrowed down to 0.15 nm FWHM, while 33 nm of tunability range between 1873 nm and 1906 nm was achieved using a pair of YAG Etalons. The laser was actively Q-switched using an acousto-optic modulator and mJ level pulse energy was measured along the whole tuning range at a repetition rate of 1 kHz. Up to 1.97 mJ of energy per pulse was achieved at a pulse duration of 37 ns at a wavelength of 1879 nm, corresponding to a peak-power of 53.2 kW and at a slope efficiency of 36 %. The combination of both high energy pulsed lasing and spectral tunability, while maintaining narrow bandwidth across the whole tunability range, enhances the laser abilities, which could enable new applications in the sensing, medical and material processing fields.
An electro-optic active -switched Tm:YLF laser (1880 nm) employing a novel, to the best of our knowledge, switching scheme is presented. The switching is done by a potassium lithium tantalate niobate (KLTN) crystal operated slightly above the ferroelectric phase transition, cut in a trapezoidal shape for reducing acousto-optic oscillations. The novel switching scheme exploits the emission cross section difference between the and polarizations in the Tm:YLF and overcomes the residual oscillation effects even at high repetition rates. The laser exhibited stable operation yielding pulses of 0.81 mJ and pulse duration of 30 ns at 5 kHz, and pulses of 1.25 mJ and pulse duration of 19 ns at 500 Hz.
This paper presents a gain-switched Ho:YAG laser at 2090 nm, pumped by a passively Q switched Tm:YLF. A pulse duration of 3.35 ns is achieved with a pulse energy of 0.7 mJ at 1.3-kHz repetition rate, corresponding to 209-kW peak power. The pump energy is 2.8 mJ, corresponding to 25% conversion efficiency with 37% slope efficiency. This laser performance with its compact design can be implemented in applications that require short pulse durations that have not been addressed to date. (c) 2022 Optica Publishing Group