Introduction: To develop and evaluate a multi-omics machine-learning model that integrates clinical variables, dose-volume histogram (DVH) metrics, radiomics, and dosiomics from both the rectum and rectal wall regions of interest (ROIs) to improve prediction of acute radiation proctitis (ARP) in cervical cancer patients receiving radiotherapy. Methods: In this single-center retrospective cohort, 107 cervical cancer patients were randomly split into a training set (n = 85) and a testing set (n = 22) in an 8:2 ratio. Radiomic were extracted from planning CT, and dosiomic features from 3-D RT-dose distributions, for both rectum and rectal wall ROIs. Features were z-score standardized; redundant features were filtered by Pearson correlation, followed by least absolute shrinkage and selection operator (LASSO) for selection. Support Vector Machine (SVM) and Multilayer Perceptron (MLP) classifiers were trained using stratified five-fold cross-validation within the training set. Model performance was assessed on the held-out test set using receiver operating characteristic (ROC) analysis; clinical utility was evaluated with decision-curve analysis (DCA). The primary endpoint was Common Terminology Criteria for Adverse Events (CTCAE,version 5.0) grade ≥2 ARP. Results: Multi-omics fusion outperformed single-modality models across ROIs and classifiers. The rectal-wall multi-omics SVM achieved the best discrimination with AUC 0.867 (95% Confidence Interval [CI]:0.709-1.000) in the test set; performance for the whole-rectum region of interest (ROI) was lower (AUC 0.714). DVH-only models showed limited discrimination, and no DVH feature was retained after penalized selection in the multi-omics pipeline. DCA demonstrated the greatest net clinical benefit for the rectal-wall multi-omics model across threshold probabilities 0.20–0.50. Conclusion: A rectal-wall, region-specific multi-omics approach integrating clinical, radiomic, and dose-based descriptors improves prediction of radiotherapy-induced ARP compared with single-modality and whole-rectum analyses. These findings highlight the importance of ROI selection and multi-omics integration for precision toxicity assessment and support future external validation and prospective evaluation.
The atomic-scale defects such as (deuterium, helium)-vacancy clusters in nuclear energy materials are one of the causes for the deterioration of the macroscopic properties of materials. Unfortunately, they cannot be observed by transmission electron microscopy (TEM) before they grow to the nanometer scale. Positron annihilation spectroscopy (PAS) has been proven to be sensitive to open-volume defects, and could characterize the evolution of the size and concentration of the vacancy-like nanoclusters. We have investigated the effects of He-D interaction on the formation of nanoscale cavities in Fe9Cr alloys by PAS and TEM. The results show that small-sized bubbles are formed in the specimen irradiated with 5 × 1016 He+/cm2, and the subsequent implanted D-ions contribute to the growth of these helium bubbles. The most likely reason is that helium bubbles previously formed in the sample captured deuterium injected later, causing bubbles to grow. In the lower dose He-irradiated samples, a large number of small dislocations and vacancies are generated and form helium-vacancy clusters with the helium atoms.