Purpose Given the potential confounding effect of fat on apparent diffusion coefficient (ADC) in the liver, we have assessed diffusion tensor imaging in liver fibrosis with minimal effect of fat on ADC and fractional anisotropy (FA). Methods Thirty-six mice were used, among which 20 mice were CCl4 treated for fibrosis induction. Diffusion tensor imaging was performed at 9.4T using a spin-echo diffusion tensor imaging sequence with six gradient directions. Hepatic fat fraction obtained by MR spectroscopy was used as hepatic fat content. Fibrosis scores were obtained from histopathology. Results The hepatic fat fractions of the two animal groups were below 5.5% and not different (5.3 ± 1.5 vs. 4.6 ± 1.1%; P = 0.115). Fibrosis scores were higher in CCl4-treated mice (0.0 ± 0.0 vs. 2.1 ± 0.7; P < 0.001). Nonetheless, there was no difference in ADC between the two groups (0.711 ± 0.068 × 10−3 vs. 0.718 ± 0.095 × 10−3 mm2 s−1; P = 0.911). The treated group had a lower FA than control (0.552 ± 0.050 vs. 0.586 ± 0.013; P = 0.023). ADC was not correlated with hepatic fat fraction and fibrosis. FA was correlated with hepatic fat fraction (r = 0.418, P = 0.011) and fibrosis (r = −0.411, P = 0.012). Conclusion FA may be more sensitive to mild-to-moderate liver fibrosis than ADC. In addition to ADC, FA may also be sensitive to hepatic fat content, and therefore need careful interpretation in liver fibrosis with concomitant fatty liver. Magn Reson Med 73:1602–1608, 2015.
A multiple quantum filter strategy is presented for spectrally discriminating metabolites with strongly coupled spins from those whose spins are either uncoupled or weakly coupled. The strategy also includes a means for selectively suppressing the background multiplets of metabolites that also have strongly coupled spins. As a demonstration of its efficacy at 3.0 T, the strategy is shown to enhance by a factor of ∼5 the signal‐to‐background ratio of the myo‐inositol band at 3.6 ppm relative to that in response to a PRESS sequence with the same sequence timings. This is done by eliminating the uncoupled resonance of glycine and the weakly coupled multiplets of glutamate and glutamine, and by selectively suppressing the strongly coupled taurine multiplet 3‐fold. The macromolecular background was effectively removed through its transverse decay over 105 ms. The associated cost of gaining the signal to background enhancement is a drop in signal yield by a factor of 0.75 relative to PRESS at the same timings. The myo‐inositol signal to noise ratio was nevertheless maintained by the filter at ∼12. Magn Reson Med 51:263–272, 2004.