A two-switch, enhanced gain single-ended primary inductor converter (SEPIC) is proposed with key benefits of enhanced voltage gain, reduced voltage stress and better efficiency, as it is suitable for low voltage green energy applications. Further, reduced voltage stress between the intermediate capacitors is a notable attribute of this converter. The converter components are designed with proper design procedure and a steady-state analysis is performed to study its operation. A small-signal analysis of the proposed converter is also presented to examine the pole-zero positions. Also, this paper includes the performance comparison with other similar converters. Simulation and experimental results of the proposed converter with a rating of 100 W/50 kHz and input and output voltages of 20 V and 200 V, respectively are provided. Efficiency as well as power loss distribution are also investigated in this study.
1 August 2018 in Journal of The Institution of Engineers (India): Series B
A four‐leg distribution static compensator (FL‐DSTATCOM) has been employed for improving the quality of power in electric distribution system using field‐programmable gate array (FPGA). A predictive current control technique without any modulation scheme is utilised to generate switching pulses for FL‐DSTATCOM using a cost function defining the preferred system behaviour. This technique makes the supply current as balanced and sinusoidal by exactly tracking the reference current, compensating the reactive power, maintaining near unity power factor and nullifies the current flow in neutral conductor during steady and dynamic state conditions. Synchronous reference frame theory is effectively implemented for extracting the reactive and harmonic part of load current which are the primary components in the evaluation of reference currents. The predictive current control scheme implemented in FPGA has been deployed to evaluate the behaviour of the FL‐DSTATCOM under multifarious loading conditions.
24 May 2018 in Engineering Science and Technology, an International Journal
A field programmable gate array (FPGA) controlled four-leg distribution static compensator (FL-DSTATCOM) has been implemented to achieve harmonic alleviation, supply current balancing, compensation of reactive power and current flow in the neutral conductor of a 4-wire 3-phase electric distribution system with static, dynamic and combined loads. The unbalanced non-linear and linear static loads are considered for analyzing compensation behaviour of FL-DSTATCOM. The practicability of FL-DSTATCOM for compensating reactive power under dynamic condition is evaluated with slip ring induction machine having variable load current. Also, the performance of FL-DSTATCOM is examined with combined load, which is a combination of dynamic and unbalanced static loads. The reference current signals are produced by using synchronous reference frame theory. Hysteresis band current controller is utilized for generating switching pulse for IGBT switches present in the FL-DSTATCOM. Independent modules are developed for realizing all the tasks in FPGA with the feasibility to reconfigure the hardware for any other application with similar requirements. The experimental results demonstrate that the FPGA controlled FL-DSTATCOM is capable of making the supply current as balanced and sinusoidal, maintaining the power factor at point of common coupling near to unity and reducing the supply neutral current very close to zero.
A four-leg distribution static compensator (FL-DSTATCOM) has been investigated to achieve harmonic elimination, supply current balancing, compensation of reactive power and current in the neutral conductor of a three-phase, four-wire distribution system with various types of static, dynamic and combined loads. The capability of FL-DSTATCOM for compensating reactive power under dynamic condition is evaluated with induction machine having variable load torque. Also, the performance of FL-DSTATCOM is evaluated with combined load, which is a combination of dynamic and unbalanced static loads. The FL-DSTATCOM injects reactive and harmonics components of load current extracted using synchronous reference frame theory. With FL-DSTATCOM, the unbalanced, harmonic and reactive loads will appear to the main power supply as balanced, linear and unity power factor load. Hence, the main power supply would deliver only fundamental frequency positive sequence components of load current. The switching pulses are generated by employing hysteresis current controller. MATLAB/SIMULINK has been used for capability evaluation under multifarious loading conditions considering IEEE standard 519. The simulation results prove that the FL-DSTATCOM is capable of making the supply current as balanced and sinusoidal, maintaining the PF at point of common coupling near to unity and reducing the supply neutral current very close to zero.