Victor Yang

Dr. Victor Yang


Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2008 in Optics Letters
Verified
Journal Article
Closed access
PDF file
AMAdrian Mariampillai
Adrian Mariampillai
BSBeau A. Standish
Beau A. Standish
EMEduardo H. Moriyama
Eduardo H. Moriyama
MKMamta Khurana
Mamta Khurana
NMNigel R. Munce
Nigel R. Munce
VYVictor Yang
Victor Yang
We report on imaging of microcirculation by calculating the speckle variance of optical coherence tomography (OCT) structural images acquired using a Fourier domain mode-locked swept-wavelength laser. The algorithm calculates interframe speckle variance in two-dimensional and three-dimensional OCT data sets and shows little dependence to the Doppler angle ranging from 75° to 90°. We demonstrate in vivo detection of blood flow in vessels as small as 25 μm in diameter in a dorsal skinfold window chamber model with direct comparison with intravital fluorescence confocal microscopy. This technique can visualize vessel-size-dependent vascular shutdown and transient vascular occlusion during Visudyne photodynamic therapy and may provide opportunities for studying therapeutic effects of antivascular treatments without on exogenous contrast agent.

1 January 2019 in The Lancet Neurology
Verified
Journal Article
Closed access
DDDominique Deplanque
Dominique Deplanque
CMCharles B L M Majoie
Charles B L M Majoie
BMBijoy K Menon
Bijoy K Menon
YNYassi Nawaf
Yassi Nawaf
GSGagan Sharma
Gagan Sharma
JCJames Cunningham
James Cunningham

30 May 2008 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
HCHazel A. Collins
Hazel A. Collins
MKMamta Khurana
Mamta Khurana
EMEduardo H. Moriyama
Eduardo H. Moriyama
AMAdrian Mariampillai
Adrian Mariampillai
EDEmma Dahlstedt
Emma Dahlstedt
HAHarry L. Anderson
Harry L. Anderson

1 October 2018 in The Lancet Neurology
Verified
Journal Article
Closed access
ARAránzazu Román-San-Miguel
Aránzazu Román-San-Miguel
BMBijoy K Menon
Bijoy K Menon
JBJordi Blasco
Jordi Blasco
MHMaría Hernández-Pérez
María Hernández-Pérez
ADAntoni Dávalos
Antoni Dávalos
JCJames Cunningham
James Cunningham

1 January 2018 in The Lancet Neurology
Verified
Journal Article
Open access
BCBruce C V Campbell
Bruce C V Campbell
MGMayank Goyal
Mayank Goyal
BMBijoy K Menon
Bijoy K Menon
DDDiederik W J Dippel
Diederik W J Dippel
ADAndrew M Demchuk
Andrew M Demchuk
JCJames Cunningham
James Cunningham
General anaesthesia (GA) during endovascular thrombectomy has been associated with worse patient outcomes in observational studies compared with patients treated without GA. We assessed functional outcome in ischaemic stroke patients with large vessel anterior circulation occlusion undergoing endovascular thrombectomy under GA, versus thrombectomy not under GA (with or without sedation) versus standard care (ie, no thrombectomy), stratified by the use of GA versus standard care. For this meta-analysis, patient-level data were pooled from all patients included in randomised trials in PuMed published between Jan 1, 2010, and May 31, 2017, that compared endovascular thrombectomy predominantly done with stent retrievers with standard care in anterior circulation ischaemic stroke patients (HERMES Collaboration). The primary outcome was functional outcome assessed by ordinal analysis of the modified Rankin scale (mRS) at 90 days in the GA and non-GA subgroups of patients treated with endovascular therapy versus those patients treated with standard care, adjusted for baseline prognostic variables. To account for between-trial variance we used mixed-effects modelling with a random effect for trials incorporated in all models. Bias was assessed using the Cochrane method. The meta-analysis was prospectively designed, but not registered. Seven trials were identified by our search; of 1764 patients included in these trials, 871 were allocated to endovascular thrombectomy and 893 were assigned standard care. After exclusion of 74 patients (72 did not undergo the procedure and two had missing data on anaesthetic strategy), 236 (30%) of 797 patients who had endovascular procedures were treated under GA. At baseline, patients receiving GA were younger and had a shorter delay between stroke onset and randomisation but they had similar pre-treatment clinical severity compared with patients who did not have GA. Endovascular thrombectomy improved functional outcome at 3 months both in patients who had GA (adjusted common odds ratio (cOR) 1·52, 95% CI 1·09-2·11, p=0·014) and in those who did not have GA (adjusted cOR 2·33, 95% CI 1·75-3·10, p<0·0001) versus standard care. However, outcomes were significantly better for patients who did not receive GA versus those who received GA (covariate-adjusted cOR 1·53, 95% CI 1·14-2·04, p=0·0044). The risk of bias and variability between studies was assessed to be low. Worse outcomes after endovascular thrombectomy were associated with GA, after adjustment for baseline prognostic variables. These data support avoidance of GA whenever possible. The procedure did, however, remain effective versus standard care in patients treated under GA, indicating that treatment should not be withheld in those who require anaesthesia for medical reasons. Medtronic.

15 April 2010 in Optics Letters
Verified
Journal Article
Closed access
PDF file
AMAdrian Mariampillai
Adrian Mariampillai
MLMichael K. K. Leung
Michael K. K. Leung
MJMark Jarvi
Mark Jarvi
BSBeau A. Standish
Beau A. Standish
KLKenneth Lee
Kenneth Lee
VYVictor Yang
Victor Yang
We optimize speckle variance optical coherence tomography (svOCT) imaging of microvasculature in high and low bulk tissue motion scenarios. To achieve a significant level of image contrast, frame rates must be optimized such that tissue displacement between frames is less than the beam radius. We demonstrate that higher accuracy estimates of speckle variance can enhance the detection of capillaries. These findings are illustrated in vivo by imaging the dorsal window chamber model (low bulk motion). We also show svOCT imaging of the nonstabilized finger (high bulk motion), using optimized imaging parameters, demonstrating better vessel detection than Doppler OCT.