Gaelle Deley

Dr. Gaelle Deley

INSERM UMR1093-CAPS, UFR des Sciences du Sport, Université de Bourgogne Franche-Comté, F-21000 Dijon, France
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Nicolas BabaultNicolas Babault
Nicolas Babault
CPChristos Paizis
Christos Paizis
Gaelle DeleyGaelle Deley
Gaelle Deley
LGLaetitia Guérin-Deremaux
Laetitia Guérin-Deremaux
MSMarie-Hélène Saniez
Marie-Hélène Saniez
FAFrançois A Allaert
François A Allaert
The effects of protein supplementation on muscle thickness and strength seem largely dependent on its composition. The current study aimed at comparing the impact of an oral supplementation with vegetable Pea protein (NUTRALYS®) vs. Whey protein and Placebo on biceps brachii muscle thickness and strength after a 12-week resistance training program. One hundred and sixty one males, aged 18 to 35 years were enrolled in the study and underwent 12 weeks of resistance training on upper limb muscles. According to randomization, they were included in the Pea protein (n = 53), Whey protein (n = 54) or Placebo (n = 54) group. All had to take 25 g of the proteins or placebo twice a day during the 12-week training period. Tests were performed on biceps muscles at inclusion (D0), mid (D42) and post training (D84). Muscle thickness was evaluated using ultrasonography, and strength was measured on an isokinetic dynamometer. Results showed a significant time effect for biceps brachii muscle thickness (P < 0.0001). Thickness increased from 24.9 ± 3.8 mm to 26.9 ± 4.1 mm and 27.3 ± 4.4 mm at D0, D42 and D84, respectively, with only a trend toward significant differences between groups (P = 0.09). Performing a sensitivity study on the weakest participants (with regards to strength at inclusion), thickness increases were significantly different between groups (+20.2 ± 12.3%, +15.6 ± 13.5% and +8.6 ± 7.3% for Pea, Whey and Placebo, respectively; P < 0.05). Increases in thickness were significantly greater in the Pea group as compared to Placebo whereas there was no difference between Whey and the two other conditions. Muscle strength also increased with time with no statistical difference between groups. In addition to an appropriate training, the supplementation with pea protein promoted a greater increase of muscle thickness as compared to Placebo and especially for people starting or returning to a muscular strengthening. Since no difference was obtained between the two protein groups, vegetable pea proteins could be used as an alternative to Whey-based dietary products. The present trial has been registered at ClinicalTrials.gov ( NCT02128516 ).

1 August 2004 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Closed access
NPNicolas Place
Nicolas Place
RLRomuald Lepers
Romuald Lepers
Gaelle DeleyGaelle Deley
Gaelle Deley
GMGuillaume Millet
Guillaume Millet
This study investigated the time course of contractile and neural alterations of knee extensor (KE) muscles during a long-duration running exercise. Nine well-trained triathletes and endurance runners sustained 55% of their maximal aerobic velocity (MAV) on a motorized treadmill for a period of 5 h. Maximal voluntary contraction (MVC), maximal voluntary activation level (%VA), and electrically evoked contractions (single and tetanic stimulations) of KE muscles were evaluated before, after each hour of exercise during short (10 min) interruptions, and at the end of the 5-h period. Oxygen uptake was also measured at regular intervals during the exercise. Reductions of MVC and %VA were significant after the 4th hour of exercise and reached -28% (P < 0.001) and -16% (P < 0.01) respectively at the end of the exercise. The reduction in MVC was highly correlated with the decline of %VA (r = 0.98, P < 0.001). M-wave was also altered after the fourth hour of exercise (P < 0.05) in both vastus lateralis and rectus femoris muscles. Peak twitch was potentiated at the end of the exercise (+18%, P = 0.01); 20- and 80-Hz maximal tetanic forces were not altered by the exercise. Oxygen uptake increased linearly during the running period (+18% at 5 h, P < 0.001). These findings suggest that KE maximal voluntary force generating capability is depressed in the final stages of a 5-h running exercise. Central activation failure and alterations in muscle action potential transmission were important mechanisms contributing to the impairment of the neuromuscular function during prolonged running.

1 November 2004 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
VMVincent Martin
Vincent Martin
GMGuillaume Millet
Guillaume Millet
AMA. Martin
A. Martin
Gaelle DeleyGaelle Deley
Gaelle Deley
GLG. Lattier
G. Lattier
The aim of this study was to compare the use of transcutaneous vs. motor nerve stimulation in the evaluation of low-frequency fatigue. Nine female and eleven male subjects, all physically active, performed a 30-min downhill run on a motorized treadmill. Knee extensor muscle contractile characteristics were measured before, immediately after (Post), and 30 min after the fatiguing exercise (Post30) by using single twitches and 0.5-s tetani at 20 Hz (P20) and 80 Hz (P80). The P20-to-P80 ratio was calculated. Electrical stimulations were randomly applied either maximally to the femoral nerve or via large surface electrodes (ES) at an intensity sufficient to evoke 50% of maximal voluntary contraction (MVC) during a 80-Hz tetanus. Voluntary activation level was also determined during isometric MVC by the twitch-interpolation technique. Knee extensor MVC and voluntary activation level decreased at all points in time postexercise (P < 0.001). P20 and P80 displayed significant time × gender × stimulation method interactions (P < 0.05 and P < 0.001, respectively). Both stimulation methods detected significant torque reductions at Post and Post30. Overall, ES tended to detect a greater impairment at Post in male and a lesser one in female subjects at both Post and Post30. Interestingly, the P20-P80 ratio relative decrease did not differ between the two methods of stimulation. The low-to-high frequency ratio only demonstrated a significant time effect (P < 0.001). It can be concluded that low-frequency fatigue due to eccentric exercise appears to be accurately assessable by ES.

17 August 2011 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
Nicolas BabaultNicolas Babault
Nicolas Babault
CCCarole Cometti
Carole Cometti
NMNicola A. Maffiuletti
Nicola A. Maffiuletti
Gaelle DeleyGaelle Deley
Gaelle Deley

1 August 2007 in Aging Clinical and Experimental Research
Verified
Journal Article
Closed access
PDF file
Gaelle DeleyGaelle Deley
Gaelle Deley
GKGaëlle Kervio
Gaëlle Kervio
JHJacques Van Hoecke
Jacques Van Hoecke
BVBénédicte Verges
Bénédicte Verges
BGBruno Grassi
Bruno Grassi
JCJean-Marie Casillas
Jean-Marie Casillas

10 September 2014 in Sports Medicine
Verified
Journal Article
Closed access
PDF file
Gaelle DeleyGaelle Deley
Gaelle Deley
JDJérémy Denuziller
Jérémy Denuziller
Nicolas BabaultNicolas Babault
Nicolas Babault