Igor Savukov

Dr. Igor Savukov

Los Alamos National Laboratory, Los Alamos, NM 87545, USA
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2008 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
VZVadim S. Zotev
Vadim S. Zotev
AMAndrei N. Matlashov
Andrei N. Matlashov
PVPetr L. Volegov
Petr L. Volegov
ISIgor Savukov
Igor Savukov
MEMichelle A. Espy
Michelle A. Espy
RKRobert H. Kraus
Robert H. Kraus

8 April 2019 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
YKYoung Jin Kim
Young Jin Kim
ISIgor Savukov
Igor Savukov
SNShaun Newman
Shaun Newman
We have constructed a low-cost, portable, high-sensitivity 16-channel optically pumped magnetometer (OPM), operating in the spin-exchange relaxation-free regime, and demonstrated its applications in magnetocardiography (MCG). The decrease in the cost of sensors by an order of magnitude is achieved by the 16-channel operation realized in a single module using a single large flat pancake rubidium vapor cell, broad pump and probe laser beams, and a 16-channel photodiode array. The OPM is also based on a fiber-coupled nearly parallel-beam configuration to facilitate multichannel design and make the system portable. For human MCG experiments, the 16-channel OPM which includes optical components is placed inside a wooden enclosure for laser safety. The enclosure is set on a nonmagnetic table inside a magnetically shielded room, while the lasers and electronics are placed outside the shielding room, to avoid magnetic noise. We show that the 16-channel OPM enables simultaneous imaging of human cardiac activity on a large area of the chest in a single scan. The multichannel capability will accelerate clinical MCG imaging to reduce the procedure time and patient fatigue.

1 August 2009 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
ISIgor Savukov
Igor Savukov
VZV.S. Zotev
V.S. Zotev
PVP.L. Volegov
P.L. Volegov
MEM.A. Espy
M.A. Espy
AMA.N. Matlashov
A.N. Matlashov
RKR.H. Kraus
R.H. Kraus

2 February 2017 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
ISIgor Savukov
Igor Savukov
YKY J Kim
Y J Kim
VSV Shah
V Shah
MBM G Boshier
M G Boshier

22 April 2016 in Scientific Reports
Verified
Journal Article
Open access
YKYoung Jin Kim
Young Jin Kim
ISIgor Savukov
Igor Savukov
Optically pumped magnetometers (OPMs) based on lasers and alkali-metal vapor cells are currently the most sensitive non-cryogenic magnetic field sensors. Many applications in neuroscience and other fields require high-resolution, high-sensitivity magnetic microscopic measurements. In order to meet this demand we combined a cm-size spin-exchange relaxation-free (SERF) OPM and flux guides (FGs) to realize an ultra-sensitive FG-OPM magnetic microscope. The FGs serve to transmit the target magnetic flux to the OPM thus improving both the resolution and sensitivity to small magnetic objects. We investigated the performance of the FG-OPM device using experimental and numerical methods, and demonstrated that an optimized device can achieve a unique combination of high resolution (80 μm) and high sensitivity (8.1 pT/). In addition, we also performed numerical calculations of the magnetic field distribution in the FGs to estimate the magnetic noise originating from the domain fluctuations in the material of the FGs. We anticipate many applications of the FG-OPM device such as the detection of micro-biological magnetic fields; the detection of magnetic nano-particles; and non-destructive testing. From our theoretical estimate, an FG-OPM could detect the magnetic field of a single neuron, which would be an important milestone in neuroscience.

22 July 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
ISIgor Savukov
Igor Savukov
TKT. Karaulanov
T. Karaulanov
Magnetic resonance imaging (MRI) is conventionally performed in very high fields, and this leads to some restrictions in applications. To remove such restrictions, the ultra-low field MRI approach has been proposed. Because of the loss of sensitivity, the detection methods based on superconducting quantum interference devices (SQUIDs) in a shielded room were used. Atomic magnetometers have similar sensitivity as SQUIDs and can also be used for MRI, but there are some technical difficulties to overcome. We demonstrate that MRI of the human brain can be obtained with an atomic magnetometer with in-plane resolution of 3 mm in 13 min.