Hugo Massé-Alarie

Dr. Hugo Massé-Alarie


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2019 in Pain Practice
Verified
Journal Article
Closed access
PDF file
STScott Tagliaferri
Scott Tagliaferri
CMClint T. Miller
Clint T. Miller
POPatrick Owen
Patrick Owen
UMUlrike H. Mitchell
Ulrike H. Mitchell
HBHelena Brisby
Helena Brisby
DBDaniel Belavy
Daniel Belavy

5 February 2012 in Experimental Brain Research
Verified
Journal Article
Closed access
PDF file
HMHugo Massé-Alarie
Hugo Massé-Alarie
VFVéronique H. Flamand
Véronique H. Flamand
HMHélène Moffet
Hélène Moffet
CSCyril Schneider
Cyril Schneider

26 December 2015 in Experimental Brain Research
Verified
Journal Article
Closed access
PDF file
HMHugo Massé-Alarie
Hugo Massé-Alarie
LBLouis-David Beaulieu
Louis-David Beaulieu
RPRichard Preuss
Richard Preuss
CSCyril Schneider
Cyril Schneider

1 March 2017 in Brain Stimulation
Verified
Journal Article
Closed access
LBLouis-David Beaulieu
Louis-David Beaulieu
VFVéronique H. Flamand
Véronique H. Flamand
HMHugo Massé-Alarie
Hugo Massé-Alarie
CSCyril Schneider
Cyril Schneider

12 January 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CMCatherine Mailloux
Catherine Mailloux
LBLouis-David Beaulieu
Louis-David Beaulieu
TWTimothy H. Wideman
Timothy H. Wideman
HMHugo Massé-Alarie
Hugo Massé-Alarie
Objective: To determine the absolute and relative intra-rater within-session test-retest reliability of pressure pain threshold (PPT) and mechanical temporal summation of pain (TSP) at the low back and the forearm in healthy participants and to test the influence of the number and sequence of measurements on reliability metrics. Methods: In 24 participants, three PPT and TSP measures were assessed at four sites (2 at the low back, 2 at the forearm) in two blocks of measurements separated by 20 minutes. The standard error of measurement, the minimal detectable change (MDC) and the intraclass correlation coefficient (ICC) were investigated for five different sequences of measurements (e.g. measurement 1, 1–2, 1-2-3). Results: The MDC for the group (MDCgr) for PPT ranged from 28.71 to 50.56 kPa across the sites tested, whereas MDCgr for TSP varied from 0.33 to 0.57 out of 10 (numeric scale). Almost all ICC showed an excellent relative reliability (between 0.80 and 0.97), except when only the first measurement was considered (moderate). Although minimal differences in absolute PPT reliability were present between the different sequences, in general, using only the first measurement increase measurement error. Three TSP measures reduced the measurement error. Discussion: We established that two measurements of PPT and three of TSP reduced the measurement error and demonstrated an excellent relative reliability. Our results could be used in future pain research to confirm the presence of true hypo/hyperalgesia for paradigms such as conditioned pain modulation or exercise-induced hypoalgesia, indicated by a change exceeding the measurement variability.

10 February 2021 in European journal of pain
Verified
Journal Article
Closed access
PDF file
ARAntoine Rohel
Antoine Rohel
JBJason Bouffard
Jason Bouffard
PPPhilippe Patricio
Philippe Patricio
NMNicolas Mavromatis
Nicolas Mavromatis
Maxime BillotMaxime Billot
Maxime Billot
HMHugo Massé-Alarie
Hugo Massé-Alarie