Existing studies show sensor faults/error could double building energy consumption and carbon emissions compared with the baseline. Those studies assume that the sensor error is fixed or constant. However, sensor faults are incipient in real conditions and there were extremely limited studies investigating the incipient sensor fault impacts systematically. This study filled in this research gap by studying time-developing sensor fault impacts to rule-based controls on a 10-zone office building. The control sequences for variable air volume boxes (VAV) with an air handling unit (AHU) system were selected based on ASHRAE Guideline 36-2018: High-Performance Sequences of Operation for HVAC Systems. Large-scale simulations on cloud were conducted (3600 cases) through stochastic approach. Results show (1) The site energy differences could go −3.3% lower or 18.1% higher, compared with baseline. (2) The heating energy differences could go −66.5% lower or 314.4% higher, compared with baseline. (3) The cooling energy differences could go −11.5% lower or 65.0% higher, compared with baseline. (4) The fan energy differences could go 0.15% lower or 6.9% higher, compared with baseline.
While it is well-known that cool roofs can efficiently reduce cooling demand in buildings, their overall energy performance in mixed and cold climates has been a topic of debate. This paper presents a comprehensive simulation study to evaluate the combined impact of roof reflectivity, insulation level, and construction type (adhered vs attached) on annual energy demand and energy costs in the United States, for different buildings and climate zones. EnergyPlus was used to model three building types (retail, office, and school buildings) for the 16 most climate-representative locations in the US using typical reflectivity and insulation values. The results show that (i) roof reflectivity is equally important to roof insulation in warm climates; (ii) for low-rise offices and schools, the benefits of reflective roofs vs dark-colored roofs are clear for all US climatic zones, with higher savings in warm climates; (iii) for big-box-retail buildings, reflective roofs perform better except for cold climate zones 7–8; (iv) dark-colored, mechanically attached roofs achieve slightly better performance than reflective roofs in mixed and cold climates. Decision makers should consider building type, climatic conditions, roof insulation levels, and durability performance, along with roof reflectivity, when assessing the overall potential benefits of cool roofs.
1 November 2025 in Journal of Physics: Conference Series
Occupant-centric building operations have incorporated occupants into the sensing and control loops of building and HVAC systems, which has shown significant potential to improve building performance. Meanwhile, there has been increasing interest in occupant thermostat override behaviours due to their complexity and impacts on building energy performance and indoor environmental quality. This simulation-based study aims to investigate the importance of considering thermostat override behaviour in the development of optimal HVAC controllers. One controller was developed in an environment without the occupant thermostat override behaviour model, whereas the other controller was developed in an environment that involves the occupant model. The comparison of the two controllers suggests that failing to consider thermostat override behaviour can lead to lower thermal satisfaction and cost savings of a controller than expected. Therefore, it is necessary to account for thermostat override behaviour to develop a reliable optimal controller.