The performance of absolute atom gravimeters used on moving platforms, such as vehicles, ships and aircrafts, is strongly affected by the vibration noise. To suppress its influence, we introduce a vibration compensation method, in which a classical accelerometer is used to measure the vibration noise. The measurement results obtained by the accelerometer show the vibration noise in the vehicle can be 2 orders of magnitude greater than that in the lab during daytime, and can induce an interferometric phase fluctuation with a standard deviation of 16.70π. With the compensation method, our vehicle-mounted atom gravimeter can work normally under harsh conditions. Comparing the Allan standard deviations before and after the vibration noise correction, we find a suppression factor of 22.74 can be achieved in static condition with a half interrogation time of T = 20 ms, resulting in a sensitivity of 1.35 mGal/Hz1/2, and a standard deviation of 0.5 mGal with an average time of 10 s. We also demonstrate the first test of an atom gravimeter in a moving vehicle, in which a suppression factor of 50.85 and a sensitivity of 60.88 mGal/Hz1/2 were realized with T = 5 ms.
A low-cost distributed temperature sensing system based on Rayleigh scattering in irradiated optical fibers was first proposed. The prototype was developed with a conventional optical time domain reflectometer and a Ge/P co-doped irradiated fiber of 100 m. Three thermal tests were conducted in the range of -40 °C ~ 60 °C. Experimental results indicate that the prototype can achieve a temperature resolution of 0.05 °C with a spatial resolution of 16.3 m at an average time of 52 s. Furthermore, the temperature resolution of the sensing system was analyzed theoretically with simulations. The simulation results show that a temperature resolution of 0.007 °C with a spatial resolution of 5 m is obtained mainly by adjusting the transmission wavelength and increasing the light source power.
21 December 2012 in Journal of Lightwave Technology
In order to explain the contradictory results on the temperature dependence of the radiation-induced attenuation (RIA) in optical fiber, the temperature dependence of color center absorption was proposed as a complementary explanation. The temperature tests were conducted on the four prototype optical fibers after irradiation. During the temperature tests the RIA in the fibers at the near infrared (NIR) wavelengths was measured continuously. The temperature dependence of color center absorption was verified. The competition between the thermally color center annealing and the temperature-dependent absorption of color center was observed. The test results show that the temperature dependent absorption of the color center at NIR wavelengths is an important factor influencing the temperature dependence of RIA besides the thermally driven color center generation, conversion and annealing process.
This paper shows a new way for measuring temperature in interferometric fiber-optic gyroscopes based on the temperature dependence of the integrated optical circuit. No component irrelevant to rotation sensing is involved. Calibration and temperature tests were conducted. The demonstrated repeatability and resolution are better than 0.5 °C. The hysteresis error is less than 1.76% full scale. The proposed method is reliable, radiation-resistant, and simple to be implemented, which would make it suitable for space application.