Abbas-Ali Zamani

Dr. Abbas-Ali Zamani


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2021 in Journal of Vibration and Control
Verified
Journal Article
Closed access
PDF file
AZAbbas-Ali Zamani
Abbas-Ali Zamani
SESadegh Etedali
Sadegh Etedali
The application of the fractional-order PID (FOPID) controller is recently becoming a topic of research interest for vibration control of structures. Some researchers have successfully implemented the FOPID controller in a single-input single-output (SISO) control structural system subjected to earthquake excitations. However, there is a lack of research that focuses on its application in multi-input multi-output (MIMO) control systems to implement it in seismic-excited structures. In this case, the cross-coupling of the process channels in the MIMO control structural system may result in a complex design process of controllers so that each loop is independently designed. From an operational point of view, the time delay and saturation limit of the actuators are other challenges that significantly affect the performance and robustness of the controller so that ignoring them in the design process may lead to unrealistic results. According to the challenges, the present study proposed an optimal fractional-order PID control design approach for structural control systems subjected to earthquake excitation. Gases Brownian motion optimization (GBMO) algorithm is utilized for optimal tuning of the controller parameters. Considering six real earthquakes and seven performance indices, the performance of the proposed controller, implemented on a ten-story building equipped with an active tendon system (ATS), is compared with those provided by the classical PID controller. Simulation results indicate that the proposed FOPID controller is more efficient than the PID in both terms of seismic performance and robustness against time-delay effects. The proposed FOPID controller can maintain suitable seismic performance in small time delays, while a significant performance loss is observed for the PID controller.

9 August 2023 in Journal of the Franklin Institute
Verified
Journal Article
Closed access
SESadegh Etedali
Sadegh Etedali
AZAbbas-Ali Zamani
Abbas-Ali Zamani
MAMorteza Akbari
Morteza Akbari
MSMohammad Seifi
Mohammad Seifi


12 May 2021 in Engineering with Computers
Verified
Journal Article
Closed access
PDF file
AZAbbas-Ali Zamani
Abbas-Ali Zamani
SESadegh Etedali
Sadegh Etedali

18 May 2022 in Smart Materials and Structures
Verified
Journal Article
Closed access
SESadegh Etedali
Sadegh Etedali
AZAbbas-Ali Zamani
Abbas-Ali Zamani
Semi-active control of base-isolated structures using magneto-rheological (MR) dampers is well studied in recent years. However, there is a study gap for sensitivity and reliability analyses assessment of the structure in the literature. Besides, the reliability analysis of the structures based on the importance of the building from a user perspective categorized into three groups including very high, high, and medium is an interesting topic that is considered in this study. Extension of the study for the case of uncontrolled base-isolated structures and controlled ones in both passive-off and passive-on modes of the MR dampers and tuning the command voltage of the MR dampers by a multi-objective modified clipped optimal (MOMCO) controller are also addressed in this paper in different seismic hazard regions with different peak ground accelerations. The Monte Carlo simulation-based Sobol’s indices and importance sampling (IS) method are applied for the sensitivity and reliability analyses. Studies are conducted on an eight-story nonlinear base-isolated structure. The sensitivity analyses show the main seismic responses are more influenced by the changing uncertainties of the stochastic ground acceleration; the mass, and stiffness of the structural model; and the yield force of the isolation system. MR dampers can significantly reduce the failure probabilities of the structures in different seismic hazard regions. By increasing seismic hazard, an increment is observed in failure probability. Enhancing the importance of the building from medium to very-high status leads to an increase in the failure probabilities of the structure in all cases. However, the performance of three control cases in reducing the failure probabilities of the structure is often increased. The MOMCO controller and passive-on mode represent fewer failure probabilities than the uncontrolled and passive-off mode in different seismic hazard regions and groups. However, the MOMCO gives the best performance in the reduction of failure probabilities.

26 August 2025 in Structures
Verified
Journal Article
Closed access
MSMohammad Shahi
Mohammad Shahi
MSMohammad Reza Sohrabi
Mohammad Reza Sohrabi
SESadegh Etedali
Sadegh Etedali
AZAbbas-Ali Zamani
Abbas-Ali Zamani