In the past, fiber-reinforced polymer (FRP) composites have been extensively used to modify the structural response of masonry brick walls. The promising advantages of FRP composites are easy application, lightweight, and very high tensile strength. However, FRP composites are very expensive, and their availability is an issue, especially in developing countries. The use of bricks is widespread in developing countries due to their low price and easy availability. Recent earthquakes and research results have demonstrated the vulnerability of existing masonry structures. In this study, we aimed to investigate the use of low-cost and readily available strengthening materials, i.e., cement-sand mortar and wire mesh, to enhance the flexural capacity of cement-clay interlocking brick (CCIB) masonry walls. The proposed strengthening materials were applied in different configurations and thicknesses. The experimental results indicated that using CS mortar and wire mesh is promising to enhance the flexural capacity of CCIB masonry walls. The flexural capacity and energy absorption capacity of the CCIB masonry wall (strengthened with 20 mm thick CS mortar and three layers of wire mesh) were 87% and 46% higher than the reference CCIB masonry wall. The results of this study can be used to improve the performance of masonry structures against earthquakes in the developing regions.
4 March 2025 in Case Studies in Construction Materials
Cement–clay Interlocking Hollow Brick Masonry (CCIHBM) walls are characterized by poor mechanical properties of bricks and mortar. Their performance is observed to be unsatisfactory under both gravity and seismic loads. There is an urgent need to develop sustainable, environmentally friendly, and low-cost strengthening materials to alter the structural behaviour of brick masonry walls in terms of strength and ductility. The results of an experimental investigation conducted on the diagonal compressive response of CCIHBM walls are presented in this study. In this experimental study, a total of six CCIHBM walls were constructed using cement–clay interlocking hollow bricks. One was tested as a control or reference wall, whereas the remaining walls were strengthened using cement mortar. In some walls, the cement mortar was also combined with the wire mesh. The research parameters included the type of Ordinary Portland Cement (OPC) (Type 1 and Type 2), thickness of cement mortar (10 mm and 20 mm), and layers of wire mesh (one and three layers). The experimental results indicate that control or unstrengthened CCIHBM walls failed in a very brittle manner at a very low ultimate load and deformation. The control CCIHBM wall, i.e., W-CON, failed at an ultimate load of 247 kN, and corresponding deflection was 1.8 mm. The strength and ductility of cement mortar and wire mesh-strengthened walls were found to be higher than the reference CCIHBM wall. For example, the ultimate load and deformation of cement-mortar-strengthened wall were found to be 143% and 233% higher than the control wall, respectively. Additionally, the ultimate failure modes of cement mortar and wire mesh strengthened were observed as ductile as compared to the brittle failure of reference wall or unstrengthened CCIHBM wall, which increased by 66% and 150% as compared with the control wall.