Najwa KANAMA

Mrs. Najwa KANAMA


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2024 in Buildings
Verified
Journal Article
Open access
PDF file
MLMarcos Batistella Lopes
Marcos Batistella Lopes
NKNajwa KANAMA
Najwa KANAMA
BPBaptiste Poirier
Baptiste Poirier
GGGaelle Guyot
Gaelle Guyot
MOMichel Ondarts
Michel Ondarts
NMNathan Mendes
Nathan Mendes
Maintaining indoor environmental quality in residential buildings is essential for occupants’ comfort, productivity, and health, with effective mechanical ventilation playing a key role in removing or diluting indoor pollutants. A two-week experimental campaign was conducted in an apartment in Lyon, France, known for its poor urban air quality, assessing temperature, relative humidity, CO2, and PM2.5 concentrations. A model verification study was performed to compare experimental measurements against numerical modeling in the living room and bedroom, leading to errors in the accuracy of the sensors. In addition, this study also investigates the impact of different ventilation strategies on indoor air quality. This research evaluates a baseline mechanical exhaust-only ventilation approach with constant air volume against two innovative smart ventilation approaches: mechanical exhaust-only ventilation with humidity control and mechanical exhaust-only ventilation with room-level CO2 and humidity control. A key contribution of this research is the novel coupling of multizone simulation models (DOMUS and CONTAM) with a CFD tool to refine pressure coefficients on the building façade, which enhances the accuracy of indoor air quality predictions. The smart ventilation strategies showed improvements, including a 20% reduction in CO2 concentration and a 5% reduction in the third-quartile PM2.5 concentration, highlighting their effectiveness in enhancing ventilation and pollutant dilution. This research provides valuable insights into advanced ventilation strategies and modeling techniques in urban environments.

11 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NKNajwa KANAMA
Najwa KANAMA
MOMichel Ondarts
Michel Ondarts
GGGaelle Guyot
Gaelle Guyot
JOJonathan Outin
Jonathan Outin
GEGonze Evelyne
Gonze Evelyne
Background and gaps. The topic of indoor air quality (IAQ) in low-energy buildings has received increasing interest over the past few years. Often based on two measurement points and on passive measurements over one week, IAQ studies are struggling to allow the calculation of pollutants exposure. Objectives. We would like to improve the evaluation of the health impacts, through measurements able to estimate the exposure of the occupants. Methodology. This article presents detailed IAQ measurements taken in an energy-efficient occupied house in France. Two campaigns were conducted in winter and spring. Total volatile organic compounds (TVOC), formaldehyde, the particle numbers and PM2.5, carbon dioxide (CO2), relative humidity (RH), temperature (T), ventilation airflows, and weather conditions were dynamically measured in several points. Laboratory and low-cost devices were used, and an inter-comparison was carried out for them. A survey was conducted to record all the daily activities of the inhabitants. IAQ performance indicators based on the different pollutants were calculated. Results. PM2.5 cumulative exposure did not exceed the threshold available in the literature. Formaldehyde concentrations were high, in the kitchen, where the average concentrations exceeded the threshold. However, the formaldehyde cumulative exposure of the occupants did not exceed the threshold. TVOC concentrations were found to reach the threshold. With these measurements performed with high spatial and temporal discretization, we showed that such detailed data allow for a better-quality health impacts assessment and for a better understanding of the transport of pollutants between rooms.