Serial quantitation of BCR-ABL mRNA levels is an important indicator of therapeutic response for patients with chronic myelogenous leukemia and Philadelphia chromosome–positive acute lymphoblastic leukemia, but there is substantial variation in the real-time quantitative polymerase chain reaction methodologies used by different testing laboratories. To help improve the comparability of results between centers we sought to develop accredited reference reagents that are directly linked to the BCR-ABL international scale. After assessment of candidate cell lines, a reference material panel comprising 4 different dilution levels of freeze-dried preparations of K562 cells diluted in HL60 cells was prepared. After performance evaluation, the materials were assigned fixed percent BCR-ABL/control gene values according to the International Scale. A recommendation that the 4 materials be established as the first World Health Organization International Genetic Reference Panel for quantitation of BCR-ABL translocation by real-time quantitative polymerase chain reaction was approved by the Expert Committee on Biological Standardization of the World Health Organization in November 2009. We consider that the development of these reagents is a significant milestone in the standardization of this clinically important test, but because they are a limited resource we suggest that their availability is restricted to manufacturers of secondary reference materials.
1 October 1987 in Journal of Immunological Methods
Protein engineering and formulation optimization strategies can be taken to minimize protein aggregation in the biopharmaceutical industry. Short-term stability measures such as the midpoint transition temperature (Tm) for global unfolding provide convenient surrogates for longer-term (e.g., 2-year) degradation kinetics, with which to optimize formulations on practical time-scales. While successful in some cases, their limitations have not been fully evaluated or understood. Tm values are known to correlate with chemical degradation kinetics for wild-type granulocyte colony stimulating factor (GCSF) at pH 4–5.5. However, we found previously that the Tm of an antibody Fab fragment only correlated with its rate of monomer loss at temperatures close to the Tm. Here we evaluated Tm, the fraction of unfolded protein (fT) at temperature T, and two additional short-term stability measures, for their ability to predict the kinetics of monomer and bioactivity loss of wild-type GCSF and four variants, at 37 °C, and in a wide range of formulations. The GCSF variants introduced one to three mutations, giving a range of conformational stabilities spanning 7.8 kcal mol–1. We determined the extent to which the formulation rank order differs across the variants when evaluated by each of the four short-term stability measures. All correlations decreased as the difference in average Tm between each pair of GCSF variants increased. The rank order of formulations determined by Tm was the best preserved, with R2-values >0.7. Tm-values also provided a good predictor (R2 = 0.73) of the aggregation rates, extending previous findings to include GCSF variant-formulation combinations. Further analysis revealed that GCSF aggregation rates at 37 °C were dependent on the fraction unfolded at 37 °C (fT37), but transitioned smoothly to a constant baseline rate of aggregation at fT37 < 10–3. A similar function was observed previously for A33 Fab formulated by pH, ionic strength, and temperature, without excipients. For GCSF, all combinations of variants and formulations fit onto a single curve, suggesting that even single mutations destabilized by up to 4.8 kcal mol–1, are insufficient to change significantly the baseline rate of aggregation under native conditions. The baseline rate of aggregation for GCSF under native conditions was 66-fold higher than that for A33 Fab, highlighting that they are a specific feature of each native protein structure, likely to be dependent on local surface properties and dynamics.
High protein concentration products for targeted therapeutic use are often freeze-dried to enhance stability. The long-term storage stability of freeze-dried (FD) plasma-derived Immunoglobulin G (IgG) from moderate to high concentrations (10–200 mg/mL) was assessed. Monomer content, binding activity and reconstitution times were evaluated over a 12-month period under accelerated and real-term storage conditions. In the first case study it was shown that FD IgG from 10 to 200 mg/mL had minimal monomer/activity losses at up to ambient temperature after 12 months of storage. However, at 45 °C the sucrose-to-protein ratio played a significant impact on IgG stability above 50 mg/mL. All IgG concentrations witnessed moisture ingress over a 12-month period. The impact of moisture ingress from environmental exposure (between 0.1% and 5% w/w moisture) for IgG 50 mg/mL was assessed, being generated by exposing low moisture batches to an atmospheric environment for fixed time periods. Results showed that at −20 °C and 20 °C there was no significant difference in terms of monomer or antigen-binding activity losses over 6 months. However, at 45 °C, there were losses in monomer content, seemingly worse for higher moisture content samples although model binding activity indicated no losses. Finally, the difference between a low moisture product (0.1–1% w/w) and a moderately high moisture (3% w/w) product generated by alternative freeze-drying cycles, both stoppered under low oxygen headspace conditions, was evaluated. Results showed that at −20 °C and 20 °C there was no difference in terms of binding activity or monomer content. However, at 45 °C, the low moisture samples had greater monomer and binding activity losses than samples from the highest moisture cycle batch, indicating that over-drying can be an issue.
1 April 2013 in Journal of Pharmaceutical and Biomedical Analysis