Tim Hilgenfeld

Dr. Tim Hilgenfeld

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2018 in International Journal of Oral Science
Verified
Journal Article
Open access
PDF file
AJAlexander Juerchott
Alexander Juerchott
TPThorsten Pfefferle
Thorsten Pfefferle
CFChrista Flechtenmacher
Christa Flechtenmacher
JMJohannes Mente
Johannes Mente
MBMartin Bendszus
Martin Bendszus
THTim Hilgenfeld
Tim Hilgenfeld
The purpose of this pilot study was to evaluate whether periapical granulomas can be differentiated from periapical cysts in vivo by using dental magnetic resonance imaging (MRI). Prior to apicoectomy, 11 patients with radiographically confirmed periapical lesions underwent dental MRI, including fat-saturated T2-weighted (T2wFS) images, non-contrast-enhanced T1-weighted images with and without fat saturation (T1w/T1wFS), and contrast-enhanced fat-saturated T1-weighted (T1wFS+C) images. Two independent observers performed structured image analysis of MRI datasets twice. A total of 15 diagnostic MRI criteria were evaluated, and histopathological results (6 granulomas and 5 cysts) were compared with MRI characteristics. Statistical analysis was performed using intraclass correlation coefficient (ICC), Cohen’s kappa (κ), Mann–Whitney U-test and Fisher’s exact test. Lesion identification and consecutive structured image analysis was possible on T2wFS and T1wFS+C MRI images. A high reproducibility was shown for MRI measurements of the maximum lesion diameter (intraobserver ICC = 0.996/0.998; interobserver ICC = 0.997), for the “peripheral rim” thickness (intraobserver ICC = 0.988/0.984; interobserver ICC = 0.970), and for all non-quantitative MRI criteria (intraobserver-κ = 0.990/0.995; interobserver-κ = 0.988). In accordance with histopathological results, six MRI criteria allowed for a clear differentiation between cysts and granulomas: (1) outer margin of lesion, (2) texture of “peripheral rim” in T1wFS+C, (3) texture of “lesion center” in T2wFS, (4) surrounding tissue involvement in T2wFS, (5) surrounding tissue involvement in T1wFS+C and (6) maximum “peripheral rim” thickness (all: P < 0.05). In conclusion, this pilot study indicates that radiation-free dental MRI enables a reliable differentiation between periapical cysts and granulomas in vivo. Thus, MRI may substantially improve treatment strategies and help to avoid unnecessary surgery in apical periodontitis.

3 May 2019 in JAMA Network Open
Verified
Journal Article
Open access
PDF file
JJJohann M. E. Jende
Johann M. E. Jende
JGJan B. Groener
Jan B. Groener
CRChristian Rother
Christian Rother
ZKZoltan Kender
Zoltan Kender
AHArtur Hahn
Artur Hahn
FKFelix T. Kurz
Felix T. Kurz
Distal symmetric diabetic polyneuropathy (DPN) is one of the most severe complications of diabetes, affecting approximately 200 million patients worldwide, with increasing prevalence leading to high morbidity and rising health care costs.1 Although the exact metabolic processes underlying DPN are still uncertain, several clinical and serologic risk factors for developing DPN, such as obesity, hypertension, hyperglycemia, dyslipidemia, and a decrease in renal function, have been identified in clinical studies.2-4 The poor outcomes after adjusting serum glucose levels in patients with type 2 diabetes (T2D) compared with type 1 diabetes (T1D) suggest that risk factors other than hyperglycemia might play an important role in the development of DPN.3,5 An in vitro study6 found that, in samples from patients with T2D and DPN, lipid composition of Schwann cells is altered compared with samples from control individuals without DPN. To date, it has not been possible to visualize those alterations in the nerve’s microstructure in vivo. Inpatient magnetic resonance neurography (MRN) at 3.0 T is a noninvasive method that allows for an exact qualitative and quantitative analysis of nerve damage in different neuropathies.7-9 Recent results from an MRN study10 in patients with DPN have shown that a decrease in serum high-density lipoprotein cholesterol (HDL-C) levels is associated with an increase in fat-equivalent lesions of the sciatic nerve and an increase in clinical symptom severity. These nerve lesions also occurred more frequently in patients with T2D compared with patients with T1D.10 The exact role of cholesterol metabolism in the development of DPN, however, is unknown, and it has not yet been determined whether lowering serum cholesterol levels in patients with T2D has a positive influence on the course of T2D DPN.11 Some clinical studies11,12 have found that a lowering of serum cholesterol levels had positive effects on the course of DPN that were mainly attributed to lowering low-density lipoprotein cholesterol (LDL-C) levels and to anti-inflammatory and antioxidative effects of statin treatment. However, low serum cholesterol levels are associated with neuropathic symptoms and impair nerve regeneration after axonal damage in neurons of the central and peripheral nervous systems.13-17 This association was mainly attributed to an insufficient supply of cholesterol to neurite tips and adjacent Schwann cells of regenerating axons as a consequence of a decrease in lipoproteins.14,18-21 With regard to emerging therapies, such as protein convertase subtilisin/kexin type 9 (PCSK9) inhibitors that promote an aggressive lowering of total serum cholesterol levels,16 it is crucial to understand whether a decrease in total serum cholesterol and LDL-C levels is beneficial or potentially harmful for patients with T2D with DPN.

1 December 2015 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
MPMarcel Prager
Marcel Prager
SHSabine Heiland
Sabine Heiland
DGDaniel Gareis
Daniel Gareis
THTim Hilgenfeld
Tim Hilgenfeld
MBMartin Bendszus
Martin Bendszus
CGChiara Gaudino
Chiara Gaudino

23 March 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AHAlexander Heil
Alexander Heil
EGEduardo Lazo Gonzalez
Eduardo Lazo Gonzalez
THTim Hilgenfeld
Tim Hilgenfeld
PKPhilipp Kickingereder
Philipp Kickingereder
MBMartin Bendszus
Martin Bendszus
SZSebastian Zingler
Sebastian Zingler
The objective of this prospective study was to evaluate whether magnetic resonance imaging (MRI) is equivalent to lateral cephalometric radiographs (LCR, “gold standard”) in cephalometric analysis. The applied MRI technique was optimized for short scanning time, high resolution, high contrast and geometric accuracy. Prior to orthodontic treatment, 20 patients (mean age ± SD, 13.95 years ± 5.34) received MRI and LCR. MRI datasets were postprocessed into lateral cephalograms. Cephalometric analysis was performed twice by two independent observers for both modalities with an interval of 4 weeks. Eight bilateral and 10 midsagittal landmarks were identified, and 24 widely used measurements (14 angles, 10 distances) were calculated. Statistical analysis was performed by using intraclass correlation coefficient (ICC), Bland-Altman analysis and two one-sided tests (TOST) within the predefined equivalence margin of ± 2°/mm. Geometric accuracy of the MRI technique was confirmed by phantom measurements. Mean intraobserver ICC were 0.977/0.975 for MRI and 0.975/0.961 for LCR. Average interobserver ICC were 0.980 for MRI and 0.929 for LCR. Bland-Altman analysis showed high levels of agreement between the two modalities, bias range (mean ± SD) was -0.66 to 0.61 mm (0.06 ± 0.44) for distances and -1.33 to 1.14° (0.06 ± 0.71) for angles. Except for the interincisal angle (p = 0.17) all measurements were statistically equivalent (p < 0.05). This study demonstrates feasibility of orthodontic treatment planning without radiation exposure based on MRI. High-resolution isotropic MRI datasets can be transformed into lateral cephalograms allowing reliable measurements as applied in orthodontic routine with high concordance to the corresponding measurements on LCR.

11 July 2017 in European Radiology
Verified
Journal Article
Closed access
PDF file
THTim Hilgenfeld
Tim Hilgenfeld
MPMarcel Prager
Marcel Prager
AHAlexander Heil
Alexander Heil
FSFranz Sebastian Schwindling
Franz Sebastian Schwindling
MNMathias Nittka
Mathias Nittka
SHSabine Heiland
Sabine Heiland

22 September 2020 in European Radiology
Verified
Journal Article
Open access
PDF file
THTim Hilgenfeld
Tim Hilgenfeld
AJAlexander Juerchott
Alexander Juerchott
JJJohann M. E. Jende
Johann M. E. Jende
PRPeter Rammelsberg
Peter Rammelsberg
SHSabine Heiland
Sabine Heiland
FSFranz S. Schwindling
Franz S. Schwindling
Objectives: To evaluate the accuracy and reliability of dental MRI for static guided implant surgery planning. Materials and methods: In this prospective study, a 0.4-mm isotropic, artifact-suppressed, 3T MRI protocol was used for implant planning and surgical guide production in participants in need of dental implants. Two dentists decided on treatment plan. Surgical guides were placed intraorally during a subsequent reference cone beam computed tomography (CBCT) scan. Inter-rater and inter-modality agreement were assessed by Cohen’s kappa. For each participant, dental MRI and CBCT datasets were co-registered to determine three-dimensional and angular deviations between planned and surgically guided implant positions. Results: Forty-five implants among 30 study participants were planned and evaluated (17 women, 13 men, mean age 56.9 ± 13.1 years). Inter-rater agreement (mean κ 0.814; range 0.704–0.927) and inter-modality agreement (mean κ 0.879; range 0.782–0.901) were both excellent for the dental MRI-based treatment plans. Mean three-dimensional deviations were 1.1 ± 0.7 (entry point) and 1.3 ± 0.7 mm (apex). Mean angular deviation was 2.4 ± 1.5°. CBCT-based adjustments of MRI plans were necessary for implant position in 29.5% and for implant axis in 6.8% of all implant sites. Changes were larger in the group with shortened dental arches compared with those for tooth gaps. Except for one implant site, all guides were suitable for clinical use. Conclusion: This feasibility study indicates that dental MRI is reliable and sufficiently accurate for surgical guide production. Nevertheless, more studies are needed to increase its accuracy before it can be used for implant planning outside clinical trials. Key Points: • An excellent reliability for the dental MRI-based treatment plans as well as agreement between dental MRI-based and CBCT-based (reference standard) decisions were noted. • Ideal implant position was not reached in all cases by dental MRI plans. • For all but one implant site surgical guides derived from dental MRI were sufficiently accurate to perform implant placement (mean three-dimensional deviations were 1.1 ± 0.7 (entry point) and 1.3 ± 0.7 mm (apex); mean angular deviation was 2.4 ± 1.5°).