Niels Roderik van der Werf

Mr. Niels Roderik van der Werf

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
NWNiels Roderik van der Werf
Niels Roderik van der Werf
SSS. Si-Mohamed
S. Si-Mohamed
PRP. A. Rodesch
P. A. Rodesch
RHR. W. van Hamersvelt
R. W. van Hamersvelt
MGM. J. W. Greuter
M. J. W. Greuter
PDP. Douek
P. Douek
Objective: The aim of the current study was, first, to assess the coronary artery calcium (CAC) scoring potential of spectral photon-counting CT (SPCCT) in comparison with computed tomography (CT) for routine clinical protocols. Second, improved CAC detection and quantification at reduced slice thickness were assessed. Methods: Raw data was acquired and reconstructed with several combinations of reduced slice thickness and increasing strengths of iterative reconstruction (IR) for both CT systems with routine clinical CAC protocols for CT. Two CAC-containing cylindrical inserts, consisting of CAC of different densities and sizes, were placed in an anthropomorphic phantom. A specific CAC was detectable when 3 or more connected voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). For all reconstructions, total CAC detectability was compared between both CT systems. Significant differences in CAC quantification (Agatston and volume scores) were assessed with Mann-Whitney U tests. Furthermore, volume scores were compared with the known CAC physical. Results: CAC scores for routine clinical protocols were comparable between SPCCT and CT. SPCCT showed 34% and 4% higher detectability of CAC for the small and large phantom, respectively. At reduced slice thickness, CAC detection increased by 142% and 169% for CT and SPCCT, respectively. In comparison with CT, volume scores from SPCCT were more comparable with the physical volume of the CAC. Conclusion: CAC scores using routine clinical protocols are comparable between conventional CT and SPCCT. The increased spatial resolution of SPCCT allows for increased detectability and more accurate CAC volume estimation. Key Points: • Coronary artery calcium scores using routine clinical protocols are comparable between conventional CT and spectral photon-counting CT. • In comparison with conventional CT, increased coronary artery calcium detectability was shown for spectral photon-counting CT due to increased spatial resolution. • Volumes scores were more accurately determined with spectral photon-counting CT.

1 November 2019 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Closed access
MWMartin J. Willemink
Martin J. Willemink
NWNiels Roderik van der Werf
Niels Roderik van der Werf
KNKoen Nieman
Koen Nieman
MGMarcel Greuter
Marcel Greuter
LKLynne M. Koweek
Lynne M. Koweek
DFDominik Fleischmann
Dominik Fleischmann

25 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
NWNiels Roderik van der Werf
Niels Roderik van der Werf
MGMargo van Gent
Margo van Gent
RBRonald Booij
Ronald Booij
DBDaniel Bos
Daniel Bos
ALAad van der Lugt
Aad van der Lugt
MSMarcel van Straten
Marcel van Straten
In order to assess coronary artery calcium (CAC) quantification reproducibility for photon-counting computed tomography (PCCT) at reduced tube potential, an anthropomorphic thorax phantom with low-, medium-, and high-density CAC inserts was scanned with PCCT (NAEOTOM Alpha, Siemens Healthineers) at two heart rates: 0 and 60–75 beats per minute (bpm). Five imaging protocols were used: 120 kVp standard dose (IQ level 16, reference), 90 kVp at standard (IQ level 16), 75% and 45% dose and tin-filtered 100 kVp at standard dose (IQ level 16). Each scan was repeated five times. Images were reconstructed using monoE reconstruction at 70 keV. For each heart rate, CAC values, quantified as Agatston scores, were compared with the reference, whereby deviations >10% were deemed clinically relevant. Reference protocol radiation dose (as volumetric CT dose index) was 4.06 mGy. Radiation dose was reduced by 27%, 44%, 67%, and 46% for the 90 kVp standard dose, 90 kVp 75% dose, 90 kVp 45% dose, and Sn100 standard dose protocol, respectively. For the low-density CAC, all reduced tube current protocols resulted in clinically relevant differences with the reference. For the medium- and high-density CAC, the implemented 90 kVp protocols and heart rates revealed no clinically relevant differences in Agatston score based on 95% confidence intervals. In conclusion, PCCT allows for reproducible Agatston scores at a reduced tube voltage of 90 kVp with radiation dose reductions up to 67% for medium- and high-density CAC.

28 December 2017 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
NWNiels Roderik van der Werf
Niels Roderik van der Werf
MWM. J. Willemink
M. J. Willemink
TWT. P. Willems
T. P. Willems
RVR. Vliegenthart
R. Vliegenthart
MGMarcel Greuter
Marcel Greuter
TLT. Leiner
T. Leiner
To evaluate the influence of heart rate on coronary calcium scores (CCS) using a dynamic phantom on four high-end computed tomography (CT) systems from different manufacturers. Artificial coronary arteries were moved in an anthropomorphic chest phantom at linear velocities, corresponding to < 60, 60–75 and > 75 beats per minute (bpm). Data was acquired with routinely used clinical protocols for CCS on four high-end CT systems (CT1–CT4). CCS, quantified as Agatston and mass scores were compared to reference scores at < 60 bpm. Influence of heart rate was assessed for each system with the cardiac motion susceptibility (CMS) Index. At increased heart rates (> 75 bpm), Agatston scores of the low mass calcification were similar to the reference score, while Agatston scores of the medium and high mass calcification increased significantly up to 50% for all CT systems. Threefold CMS increases at > 75 bpm in comparison with < 60 bpm were shown. For medium and high mass calcifications, significant differences in CMS between CT systems were found. Heart rate substantially influences CCS for high-end CT systems of four major manufacturers, but CT systems differ in motion susceptibility. Follow-up CCS CT scans should be acquired on the same CT system and protocol, and preferably with comparable heart rates.

1 September 2018 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Closed access
MVMarleen Vonder
Marleen Vonder
NWNiels Roderik van der Werf
Niels Roderik van der Werf
TLTim Leiner
Tim Leiner
MGMarcel Greuter
Marcel Greuter
DFDominik Fleischmann
Dominik Fleischmann
MWMartin J. Willemink
Martin J. Willemink

8 January 2022 in European Radiology
Verified
Journal Article
Closed access
PDF file
NWNiels Roderik van der Werf
Niels Roderik van der Werf
PRP. A. Rodesch
P. A. Rodesch
SSS. Si-Mohamed
S. Si-Mohamed
RHR. W. van Hamersvelt
R. W. van Hamersvelt
MGM. J. W. Greuter
M. J. W. Greuter
PDP. Douek
P. Douek