Haiwei Xu

Dr. Haiwei Xu

College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2023 in Engineering Structures
Verified
Journal Article
Closed access
Haiwei XuHaiwei Xu
Haiwei Xu
KDKunyang Ding
Kunyang Ding
guohui shenguohui shen
guohui shen
HDHang Du
Hang Du
YCYong Chen
Yong Chen

20 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
JLJunlong Li
Junlong Li
GHGuanhao Hong
Guanhao Hong
Haiwei XuHaiwei Xu
Haiwei Xu
The cable-suspended PV system has gained increasing popularity due to its large span and good site adaptability. However, this structure is quite sensitive to wind actions, and wind-induced module damage and structure failure have been frequently reported. Therefore, in this study, we carried out wind tunnel tests to study wind load effects on PV arrays with different lengths and widths. Considering the wind sheltering effects of upstream modules, reduction factors for the wind load were proposed in different array zones. Numerical simulations of wind-induced vibration and equivalent static analysis were conducted to yield gust loading factors for the PV array. This study showed that the maximum wind suction and pressure for the middle zone occurred at 0° and 180°, respectively, while those for the outermost zone appeared under oblique flows (e.g., 30° and 150°). For the PV modules beyond the windward fourth row, the reduction factors of the wind loads were 0.4 (maximum suction) and 0.2 (maximum pressure) for the middle zone and 0.5 (maximum suction) and 0.75 (maximum pressure) for the outermost zone. The gust loading factors for the typical wind directions of 0° and 180° varied from 2.2 to 2.7 for the middle zone and from 1.3 to 1.5 for the outermost zone.

2 July 2019 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
WLWenjuan Lou
Wenjuan Lou
DWDengguo Wu
Dengguo Wu
Haiwei XuHaiwei Xu
Haiwei Xu

1 November 2024 in Journal of Zhejiang University-SCIENCE A
Verified
Journal Article
Closed access
ANAli Matin Nazar
Ali Matin Nazar
Haiwei XuHaiwei Xu
Haiwei Xu
MHMingfeng Huang
Mingfeng Huang

1 June 2018 in Journal of Engineering Mechanics
Verified
Journal Article
Closed access
Haiwei XuHaiwei Xu
Haiwei Xu
WLWenjuan Lou
Wenjuan Lou
Wind-induced internal pressure arising from door or window failure during severe wind conditions has been studied extensively. Most previous studies focus on the cases of openings in the wall, but little attention has been paid to the internal pressure responses of a building with a dominant opening on the roof, although this situation appears frequently due to wind-induced damage or functional use. This paper examines the internal pressure characteristics produced by wind action through a dominant opening on a hemi-ellipsoidal roof and investigates its potential influence factors, including opening sizes, locations, internal volume, and ambient interference. An opening in the wall was also studied and compared with the case having the same size opening on the roof. The study shows that internal pressures were basically negative under roof opening cases but might become positive at several wind azimuths when there is an interfering building nearby. Spectra of internal pressures contained two resonance peaks, which corresponded to Helmholtz resonance and vortex shedding, respectively, and varied significantly with wind directions. Due to the coupling effect of vortex shedding, the classical Helmholtz frequency equation, and the current volume adjustment method to maintain frequency similarity between full-scale and model-scale might be unsuitable for roof opening cases. Reducing the internal volume increased the standard deviation of internal pressure, but had an insignificant effect on its mean values. Compared with the roof opening case, wind actions through an opening in the wall would generate worse net suctions on the roof but lead to a smaller Helmholtz resonance frequency. Roof failure resulted in larger maximum internal suctions than wall failure and was thus more dangerous to the windward wall bearing positive external pressures. Internal pressure responses controlled by Helmholtz resonance could be deemed as a quasi-Gaussian processes. The ambient interferences could affect Gaussian characteristics of internal pressures.

1 August 2019 in Journal of Zhejiang University-SCIENCE A
Verified
Journal Article
Closed access
YCYong Chen
Yong Chen
YGYong Guo
Yong Guo
Haiwei XuHaiwei Xu
Haiwei Xu