Jérôme Kaeslin

Mr. Jérôme Kaeslin


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2021 in Metabolites
Verified
Journal Article
Open access
PDF file
JKJérôme Kaeslin
Jérôme Kaeslin
SMSrdjan Micic
Srdjan Micic
RWRonja Weber
Ronja Weber
SMSimona Müller
Simona Müller
NPNathan Perkins
Nathan Perkins
AMAlexander Moeller
Alexander Moeller
Identifying and differentiating bacteria based on their emitted volatile organic compounds (VOCs) opens vast opportunities for rapid diagnostics. Secondary electrospray ionization high-resolution mass spectrometry (SESI-HRMS) is an ideal technique for VOC-biomarker discovery because of its speed, sensitivity towards polar molecules and compound characterization possibilities. Here, an in vitro SESI-HRMS workflow to find biomarkers for cystic fibrosis (CF)-related pathogens P. aeruginosa, S. pneumoniae, S. aureus, H. influenzae, E. coli and S. maltophilia is described. From 180 headspace samples, the six pathogens are distinguishable in the first three principal components and predictive analysis with a support vector machine algorithm using leave-one-out cross-validation exhibited perfect accuracy scores for the differentiation between the groups. Additionally, 94 distinctive features were found by recursive feature elimination and further characterized by SESI-MS/MS, which yielded 33 putatively identified biomarkers. In conclusion, the six pathogens can be distinguished in vitro based on their VOC profiles as well as the herein reported putative biomarkers. In the future, these putative biomarkers might be helpful for pathogen detection in vivo based on breath samples from patients with CF.

29 April 2020 in Chimia
Verified
Journal Article
Open access
JKJérôme Kaeslin
Jérôme Kaeslin
Microfluidic autosamplers for electrospray ionization mass spectrometry (ESI-MS) are of major importance when using ESI-MS as a high-throughput and low sample consumption analytical method. In this article, microfluidic ESI-MS autosampler designs are overviewed and a group-owned prototype is discussed. The socalled gap sampler is a pin-based sampler for miniaturized flow injection (FI) analysis. To date, it has been used in various applications. Following proof of concept applications with FI of small molecules, pin modifications were implemented for unspecific and specific extraction for the analysis of complex samples. Most recently, further optimization allowed the study of non-covalent protein-ligand interactions for bioaffinity screenings, which constitutes a major milestone in the development of this novel high-throughput autosampler.

28 July 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
JLJiayi Lan
Jiayi Lan
JKJérôme Kaeslin
Jérôme Kaeslin
GGGiorgia Greter
Giorgia Greter
RZRenato Zenobi
Renato Zenobi
Secondary electrospray ionization high-resolution mass spectrometry (SESI-HR-MS) is an emerging technique for the detection of volatile metabolites. However, sensitivity and reproducibility of SESI-HRMS have limited its applications in untargeted metabolomics profiling. Ion suppression in the SESI source has been considered to be the main cause. Here, we show that besides ion suppression, ion competition in the C-trap of Orbitrap instruments is another important factor that influences sensitivity and reproducibility of SESI-MS. Instead of acquiring the full mass-to-charge ratio ( m/z ) range, acquisition of consecutive m/z windows to minimize the ion competition effect allows the detection of more features. m/z window ranges are optimized to fill the C-trap either with an equal number of features or an equal cumulative intensity per window. Considering a balance between maximizing scanning speed and minimizing ion competition, splitting the m/z = 50-500 range into 4 windows is selected for measuring human breath and bacterial culture samples on SESI-Orbitrap MS, corresponding to a duty cycle of 2.3 s at a resolution of 140’000. In a small cohort of human subjects, the proposed splitting into 4 windows allows three times more features to be detected compared to the classical full m/z range method.