Jarmo Alander

Dr. Jarmo Alander


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in International Journal of Biomedical Imaging
Verified
Journal Article
Open access
PDF file
JAJarmo Alander
Jarmo Alander
IKIlkka Kaartinen
Ilkka Kaartinen
ALAki Laakso
Aki Laakso
TPTommi Pätilä
Tommi Pätilä
TSThomas Spillmann
Thomas Spillmann
PVPetri Välisuo
Petri Välisuo
The purpose of this paper is to give an overview of the recent surgical intraoperational applications of indocyanine green fluorescence imaging methods, the basics of the technology, and instrumentation used. Well over 200 papers describing this technique in clinical setting are reviewed. In addition to the surgical applications, other recent medical applications of ICG are briefly examined.

9 September 2007
Verified
Conference Paper
Closed access
JKJanne Koljonen
Janne Koljonen
OKOlli Kanniainen
Olli Kanniainen
JAJarmo Alander
Jarmo Alander
Image matching is a common procedure in computer vision. Usually the size of the image template is fixed. If the matching is done repeatedly, as e.g. in stereo vision, object tracking, and strain measurements, it is beneficial, in terms of computational cost, to use as small templates as possible. On the other hand larger templates usually give more reliable matches, unless e.g. projective distortions become too great. If the template size is controlled locally dynamically, both computational efficiency and reliability can be achieved simultaneously. Adaptive template size requires though that a larger template can be sampled anytime. This paper introduces a method to adaptively control the template size in a digital image correlation based strain measurement algorithm. The control inputs are measures of confidence of match. Some new measures are proposed in this paper, and the ones found in the literature are reviewed. The measures of confidence are tested and compared with each other as well as with a reference method using templates of fixed size. The comparison is done with respect to computational complexity and accuracy of the algorithm. Due to complex inter-actions of the free parameters of the algorithm, random search is used to find an optimal parameter combination to attain a more reliable comparison. The results show that with some confidence measures the dynamic scheme outperforms the static reference method. However, in order to benefit from the dynamic scheme, optimization of the parameters is needed.

1 January 2007
Verified
Conference Paper
Closed access
JKJanne Koljonen
Janne Koljonen
OKOlli Kanniainen
Olli Kanniainen
JAJarmo Alander
Jarmo Alander
A digital image correlation algorithm for strain measurements with some improvements is introduced and tested. A major problem related to strain measurements with spatial resolution is the lack of simple validation of the results as the overall strain given by the test machine is not applicable as a local strain reference estimate. An implicit error estimation approach based on statistical analysis is introduced and applied to an image test set from a uniaxial tensile test of a planar aluminum test piece. The spatial strain sampling frequency and the measurement accuracy and errors are studied, when varying a few parameters of the algorithm. An intra-validation procedure is in turn used to validate the error estimates.