Hassane Oudadesse

Prof. Hassane Oudadesse


Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2011 in Biomedical Materials
Verified
Journal Article
Closed access
HOHassane Oudadesse
Hassane Oudadesse
EDE Dietrich
E Dietrich
YGY L Gal
Y L Gal
PPP Pellen
P Pellen
BBB Bureau
B Bureau
GCG Cathelineau
G Cathelineau
The use of bone grafts permits the filling of a bone defect without risk of virus transmission. In this work, pure bioactive glass (46S6) and zinc-doped bioactive glass (46S6Zn10) with 0.1 wt% zinc are used to elaborate highly bioactive materials by melting and rapid quenching. Cylinders of both types of glasses were soaked in a simulated body fluid (SBF) solution with the aim of determining the effect of zinc addition as a trace element on the chemical reactivity and bioactivity of glass. Several physico-chemical characterization methods such as x-ray diffraction, Fourier transform infrared spectroscopy and nuclear magnetic resonance methods, with particular focus on the latter, were chosen to investigate the fine structural behaviour of pure and Zn-doped bioactive glasses as a function of the soaking time of immersion in SBF. Inductively coupled plasma-optical emission spectroscopy (ICP-OES) was used to measure the concentrations of Ca and P ions in the SBF solution after different durations of immersion. The effect of the investigated samples on the proliferation rate of human osteoblast cells was assessed by the 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assay, and tested on two different sizes of pure and zinc-doped glasses in powder form, with particle sizes that ranged between 40 to 63 µm and 500 to 600 µm. The obtained results showed the delay release of ions by Zn-doped glass (46S6Zn10) and the slower CaP deposition. Cytotoxicity and cell viability were affected by the particle size of the glass. The release rate of ions was found to influence the cell viability.

19 September 2008 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
FMF. Z. Mezahi
F. Z. Mezahi
HOHassane Oudadesse
Hassane Oudadesse
AHA. Harabi
A. Harabi
ALA. Lucas-Girot
A. Lucas-Girot
YGY. Le Gal
Y. Le Gal
GCG. Cathelineau
G. Cathelineau

14 December 2006 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
HOHassane Oudadesse
Hassane Oudadesse
ADA. C. Derrien
A. C. Derrien
MLM. Lefloch
M. Lefloch
JDJ. Davidovits
J. Davidovits

31 July 2012 in Journal of Applied Biomedicine
Verified
Journal Article
Open access
PDF file
SJSamira Jebahi
Samira Jebahi
HOHassane Oudadesse
Hassane Oudadesse
HFHafed el Feki
Hafed el Feki
TRTarek Rebai
Tarek Rebai
HKHassib Keskes
Hassib Keskes
AFAbdelfattah el Feki
Abdelfattah el Feki
Recently, oxidative stress has been identified as a pivotal pathological factor inducing bone osteoporosis. This phenomenon is responsible for low bone density. It alters bone quality and generates bone fractures. Strontium is found to induce ...

25 June 2020 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Closed access
PDF file
HOHassane Oudadesse
Hassane Oudadesse
SNSanaa Najem
Sanaa Najem
SMSiwar Mosbahi
Siwar Mosbahi
NRNicolas Rocton
Nicolas Rocton
JRJihen Refifi
Jihen Refifi
BLBertrand Lefeuvre
Bertrand Lefeuvre

19 February 2021 in Minerals
Verified
Journal Article
Open access
PDF file
HSHamid AIT SAID
Hamid AIT SAID
HNHassan NOUKRATI
Hassan NOUKRATI
HYHicham Ben youcef
Hicham Ben youcef
ABAyoub Bayoussef
Ayoub Bayoussef
HOHassane Oudadesse
Hassane Oudadesse
ABAllal BARROUG
Allal BARROUG
Three-dimensional hydroxyapatite-chitosan (HA-CS) composites were formulated via solid-liquid technic and freeze-drying. The prepared composites had an apatitic nature, which was demonstrated by X-ray diffraction and Infrared spectroscopy analyses. The impact of the solid/liquid (S/L) ratio and the content and the molecular weight of the polymer on the composite mechanical strength was investigated. An increase in the S/L ratio from 0.5 to 1 resulted in an increase in the compressive strength for HA-CSL (CS low molecular weight: CSL) from 0.08 ± 0.02 to 1.95 ± 0.39 MPa and from 0.3 ± 0.06 to 2.40 ± 0.51 MPa for the HA-CSM (CS medium molecular weight: CSM). Moreover, the increase in the amount (1 to 5 wt%) and the molecular weight of the polymer increased the mechanical strength of the composite. The highest compressive strength value (up to 2.40 ± 0.51 MPa) was obtained for HA-CSM (5 wt% of CS) formulated at an S/L of 1. The dissolution tests of the HA-CS composites confirmed their cohesion and mechanical stability in an aqueous solution. Both polymer and apatite are assumed to work together, giving the synergism needed to make effective cylindrical composites, and could serve as a promising candidate for bone repair in the orthopedic field.