Background: Impedance-based remote monitoring (RM) failed to reduce clinical events in the OptiLink heart failure (HF) trial. However, rates of alert-driven interventions triggered by intrathoracic fluid index threshold crossings (FTC) were low indicating physicians’ inappropriate reactions to alerts. Methods: We separated appropriate from inappropriate contacts to FTC transmissions in the OptiLink HF trial (Optimization of Heart Failure Management Using OptiVol™ Fluid Status Monitoring and CareLink™). Appropriate contacts had to meet the following criteria: (1) initial telephone contact within 2 working days after FTC transmission, (2) follow-up contacts according to study protocol, and (3) medical intervention initiated after FTC due to cardiac decompensation. We compared time to cardiovascular death or HF hospitalization between RM patients contacted appropriately or inappropriately and patients with usual care. Results: In the RM group, at least one FTC alert was transmitted in 356 patients (70.5%; n=505). Of note, only 55.5% (n=758) of all transmitted FTCs (n=1365) were followed by an appropriate contact. While 113 patients (31.7%; n=356) have been contacted appropriately after every FTC, in 243 patients (68.3%; n=356) at least one FTC was not responded by an appropriate contact. Compared with usual care, RM with appropriate contacts to FTC alerts independently reduced the risk of the primary end point (hazard ratio, 0.61 [95% CI, 0.39–0.95]; P =0.027). Conclusions: RM appropriate reactions to FTC alerts are associated with significantly improved clinical outcomes in patients with advanced HF and implantable cardioverter-defibrillators.
(1) Background: Atrial fibrillation (AF) is associated with anxiety, depression, and chronic stress, and vice versa. The purpose of this study was to evaluate potential effects of pulmonary vein isolation (PVI) on psychological factors. (2) Methods: Psychological assessment was performed before PVI as well as after six months. (3) Results: A total of 118 patients [age 64 ± 9 years, 69% male, left ventricular ejection fraction 57 ± 8%, 56% paroxysmal AF] undergoing PVI were included. After PVI, significant improvements were observed in the mean total heart-focused anxiety (HFA) score, as well as in the Cardiac Anxiety Questionnaire (CAQ) sub-scores: HFA attention, HFA fear, and HFA avoidance scores. Subgroup analyses showed an association of improvement with freedom of documented AF recurrence. Mean scores of general anxiety and depression evaluated by the Hospital Anxiety and Depression Scale (HADS) decreased significantly after PVI in all subgroups regardless of AF recurrence. Further, both physical and mental composite scores of the Short Form Health Survey (SF-12) increased significantly from baseline. (4) Conclusions: PVI results in a significant reduction in HFA. Improvements in general anxiety and depressive symptoms did not seem to be related only to rhythm control per se. Therefore, CAQ may represent a more specific evaluation tool as HADS in patients with AF.
21 January 2023 in Clinical Research in Cardiology
Aim: Transcatheter aortic valve replacement (TAVR) can cause intraventricular conduction disturbances (ICA), particularly left bundle branch block (BBB) and high-degree atrioventricular block (HAVB). The aim of this study was to investigate clinical, anatomical, procedural, and electrophysiological parameters predicting ICA after TAVR. Methods: Patients with severe aortic stenosis (n = 203) without pacing devices undergoing TAVR with a self-expanding (n = 103) or balloon-expanding (n = 100) valve were enrolled. Clinical and anatomical parameters, such as length of the membranous septum (MS) and implantation depth, were assessed. His-ventricular interval (HVi) before and after implantation was determined. 12-lead-electrocardiograms (ECG) before, during and after 3 and 30 days after TAVR were analyzed for detection of any ICA. Results: Among 203 consecutive patients (aortic valve area 0.78 ± 0.18 cm2, age 80 ± 6 years, 54% male, left ventricular ejection fraction 52 ± 10%), TAVR led to a significant prolongation of infranodal conduction in all patients from 49 ± 10 ms to 59 ± 16 ms (p = 0.01). The HVi prolongation was independent of valve types, occurrence of HAVB or ICA. Fifteen patients (7%) developed HAVB requiring permanent pacemaker (PPM) implantation and 63 patients (31%) developed ICA within 30 days. Pre-existing BBB (OR 11.64; 95% CI 2.87–47.20; p = 0.001), new-onset left BBB (OR 15.72; 95% CI 3.05–81.03; p = 0.001), and diabetes mellitus (OR 3.88; 95% CI 1.30–15.99; p = 0.02) independently predicted HAVB requiring PPM. Neither pre-existing right BBB, a prolonged postHVi, increases in PR duration, any of the TAVR implantation procedural and anatomic nor echocardiographic characteristics were predictive for later HAVB. Conclusions: New-onset left BBB and diabetes mellitus independently predicted HAVB requiring PPM after TAVR and helped to identify patients at risk. Electrophysiologic study (EPS) of atrioventricular conduction was neither specific nor predictive of HAVB and can be skipped. Trial registration number: NCT04128384 (https://www.clinicaltrials.gov). Graphical
Background: Patients who have undergone prior pulmonary vein isolation (PVI) for atrial fibrillation (AF) often require a repeat ablation for AF recurrence. The optimal ablative strategy for the redo procedure and predictors of AF recurrence thereafter remain largely unknown. Purpose: We aimed to characterise the ablation strategies applied at re-PVI and identify possible predictors of AF recurrence. Methods: Our single-centre, retrospective study included all consecutive patients who underwent first redo PVI at our centre from 2017 to 2022. Inclusion criteria required at least one available follow-up visit within the first 12 months after the redo procedure. Ablation strategies of the initial and redo procedure were captured. Kaplan-Meier curves were used to illustrate time of AF recurrence, as classified by predictors of outcome determined by multivariable regression analyses. Results: We included 215 patients (39.1% female) with a median age of 66.6 years (IQR 58.6-73.2) at the time of redo procedure. The initial PVI was cryoablation in 39.9%, RFA in 57.7% and surgical ablation in 2.4%. After the initial procedure, 55.8% had paroxysmal AF and 44.2% had persistent AF. At the redo procedure, 25.1% of patients were found to have no PV reconnection, whereas 20.5% had a single reconnected PV, and 54.4% had two or more reconnected PVs. A left-sided flutter ablation was performed in 18.8%, a left atrial (LA) roof line in 16.9%, a posterior mitral isthmus line in 5.2%, an anterior mitral isthmus line in 27.9%, and a posterior box lesion in 8.4%. Overall, 34.4% of patients showed areas of low-voltages in the redo procedure. Patients with areas of low voltages were less likely to have any reconnected PVs in the redo-procedure (p<0.001). After the second ablation procedure, 54.0% experienced AF recurrence. Univariable regression analysis revealed moderate (p=0.006) or severe (p= 0.015) LA dilatation, persistent AF (p=0.005), and posterior LA low voltage areas (p=0.011) as significant predictors of AF recurrence after the redo procedure. The number of reconnected PVs at the re-PVI did not predict AF recurrence (p=0.1090). As illustrated in Fig. 1 and 2, patients with paroxysmal AF experienced less AF recurrence compared to those with persistent AF (log-rank p=0.0025). Moreover, moderate or severe LA dilatation at baseline was associated with more frequent AF recurrences (log-rank p=0.0279). Conclusion: A significant proportion of patients undergoing re-PVI experienced AF recurrence. We found that persistent AF and moderate or severe LA enlargement emerged as significant predictors of AF recurrence after the redo procedure. Although PV reconnection was observed in more than two thirds of patients at the re-PVI, it did not predict AF recurrence thereafter. However, patients without PV reconnection had significantly more low-voltage areas, which may be indicative of a different AF recurrence mechanism in this subgroup.Figure 1:Type of AFFigure 2:LA dilatation